Search Results - "Loree, Howard M."

  • Showing 1 - 15 results of 15
Refine Results
  1. 1

    In Vitro Study of a Medical Device to Enhance Arteriovenous Fistula Eligibility and Maturation by Loree, Howard M, Agyapong, George, Favreau, Elyse G, Ngai, Gwendolyn A, Tansley, Geoff D, Dixon, Bradley S, Franano, F Nicholas

    Published in ASAIO journal (1992) (01-07-2015)
    “…The arteriovenous fistula eligibility (AFE) system (Flow Forward Medical, Olathe, KS) is a small, temporary, wearable rotary blood pump system designed to…”
    Get full text
    Journal Article
  2. 2

    Static circumferential tangential modulus of human atherosclerotic tissue by Loree, H M, Grodzinsky, A J, Park, S Y, Gibson, L J, Lee, R T

    Published in Journal of biomechanics (01-02-1994)
    “…The mechanical properties of atherosclerotic plaque may be of critical importance to the processes of plaque rupture, the most common antecedent of myocardial…”
    Get more information
    Journal Article
  3. 3
  4. 4

    Computational Fluid Dynamics Analysis of a Maglev Centrifugal Left Ventricular Assist Device by Burgreen, Greg W., Loree, Howard M., Bourque, Kevin, Dague, Charles, Poirier, Victor L., Farrar, David, Hampton, Edward, Wu, Z. Jon, Gempp, Thomas M., Schöb, Reto

    Published in Artificial organs (01-10-2004)
    “…: The fluid dynamics of the Thoratec HeartMate III (Thoratec Corp., Pleasanton, CA, U.S.A.) left ventricular assist device are analyzed over a range of…”
    Get full text
    Journal Article
  5. 5

    Circumferential Stress and Matrix Metalloproteinase 1 in Human Coronary Atherosclerosis: Implications for Plaque Rupture by Lee, Richard T, Schoen, Frederick J, Loree, Howard M, Lark, Michael W, Libby, Peter

    “…Atherosclerotic plaque rupture may occur when regions of weakened extracellular matrix are subjected to increased mechanical stresses. Since collagen is a…”
    Get full text
    Journal Article
  6. 6

    Effects of Fibrous Cap Thickness on Peak Circumferential Stress in Model Atherosclerotic Vessels by Loree, Howard M, Kamm, Roger D, Stringfellow, Richard G, Lee, Richard T

    Published in Circulation research (01-10-1992)
    “…It is likely that factors other than stenosis severity predispose some atherosclerotic plaques to rupture. Because focal increases in circumferential stress…”
    Get full text
    Journal Article
  7. 7
  8. 8

    Incorporation of Electronics within a Compact, Fully Implanted Left Ventricular Assist Device by Bourque, Kevin, Gernes, David B., Loree II, Howard M., Richardson, J. Scott, Poirier, Victor L., Barletta, Natale, Fleischli, Andreas, Foiera, Giampiero, Gempp, Thomas M., Schoeb, Reto

    Published in Artificial organs (01-11-2002)
    “…: The promise of expanded indications for left ventricular assist devices in the future for very long‐term applications (10+ years) prompts sealed (i.e. fully…”
    Get full text
    Journal Article
  9. 9

    Data-Based Modelling of the Arteriovenous Fistula Eligibility (AFE) System for Wall Shear Stress Estimation by Golesorkhie, Farya, Barnes, Zachary, Yang, Fuwen, Loree, Howard M., Franano, F. Nicholas, Vlacic, Ljubo, Tansley, Geoff

    “…The AFE System is a medical device intended to dilate the cephalic vein by increasing the blood flow and wall shear stress (WSS) in the vein over a period of…”
    Get full text
    Conference Proceeding
  10. 10

    Computational structural analysis based on intravascular ultrasound imaging before in vitro angioplasty: Prediction of plaque fracture locations by Lee, Richard T., Loree, Howard M., Cheng, George C., Lieberman, Eric H., Jaramillo, Nicholas, Schoen, Frederick J.

    “…Objectives. This in vitro study was designed to test the hypothesis that a structural analysis based on intravascular ultrasound images of atherosclerotic…”
    Get full text
    Journal Article
  11. 11

    HeartMate III: Pump Design for a Centrifugal LVAD with a Magnetically Levitated Rotor by Bourque, Kevin, Gernes, David B, Loree, Howard M, Scott Richardson, J, Poirier, Victor L, Barletta, Natale, Fleischli, Andreas, Foiera, Giampiero, Gempp, Thomas M, Schoeb, Reto, Litwak, Kenneth N, Akimoto, Takehide, Watach, Mary J, Litwak, Philip

    Published in ASAIO journal (1992) (01-07-2001)
    “…A long-term, compact left ventricular assist device (LVAD), the HeartMate III, has been designed and fabricated, featuring a centrifugal pump with a…”
    Get full text
    Journal Article
  12. 12

    Distribution of circumferential stress in ruptured and stable atherosclerotic lesions : a structural analysis with histopathological correlation by CHENG, G. C, LOREE, H. M, KAMM, R. D, FISHBEIN, M. C, LEE, R. T

    Published in Circulation (New York, N.Y.) (01-04-1993)
    “…Although rupture of an atherosclerotic plaque is considered to be the cause of most acute coronary syndromes, the mechanism of plaque rupture is controversial…”
    Get full text
    Journal Article
  13. 13

    Prediction of mechanical properties of human atherosclerotic tissue by high-frequency intravascular ultrasound imaging. An in vitro study by Lee, R T, Richardson, S G, Loree, H M, Grodzinsky, A J, Gharib, S A, Schoen, F J, Pandian, N

    Published in Arteriosclerosis and thrombosis (01-01-1992)
    “…Intravascular ultrasound may be useful for studying the natural history of atherosclerotic lesions of different morphologies and for guiding interventional…”
    Get full text
    Journal Article
  14. 14

    High stress regions in saphenous vein bypass graft atherosclerotic lesions by Lee, Richard T., Loree, Howard M., Fishbein, Michael C.

    “…Objectives. Our aim was to test the hypothesis that maximal stresses in saphenous vein atherosclerotic stenoses are greater than those in native coronary…”
    Get full text
    Journal Article
  15. 15