    MRI-Linear Accelerator Radiotherapy Systems by Liney, G.P., Whelan, B., Oborn, B., Barton, M., Keall, P.

    “…The desire to utilise soft-tissue image guidance at the time of radiation treatment has led to the development of several hybrid magnetic resonance imaging…”
    Get full text
    Journal Article
  2. 2

    Towards real-time 4D radiation dosimetry on an MRI-Linac by De Deene, Y, Wheatley, M, Dong, B, Roberts, N, Jelen, U, Waddington, D, Liney, G

    Published in Physics in medicine & biology (24-11-2020)
    “…4D radiation dosimetry using a highly radiation-sensitive polymer gel dosimeter with real-time quantitative magnetic resonance imaging (MRI) readout is…”
    Get more information
    Journal Article
  3. 3

    Quantitative MRI: Defining repeatability, reproducibility and accuracy for prostate cancer imaging biomarker development by Wang, Y., Tadimalla, S., Rai, R., Goodwin, J., Foster, S., Liney, G., Holloway, L., Haworth, A.

    Published in Magnetic resonance imaging (01-04-2021)
    “…Quantitative MRI (qMRI) parameters have been increasingly used to develop predictive models to accurately monitor treatment response in prostate cancer after…”
    Get full text
    Journal Article
  4. 4

    The Potential for an Enhanced Role for MRI in Radiation-Therapy Treatment Planning by Metcalfe, P., Liney, G. P., Holloway, L., Walker, A., Barton, M., Delaney, G. P., Vinod, S., Tomé, W.

    Published in Technology in cancer research & treatment (01-10-2013)
    “…The exquisite soft-tissue contrast of magnetic resonance imaging (MRI) has meant that the technique is having an increasing role in contouring the gross tumor…”
    Get full text
    Journal Article
  5. 5

    Anatomical deformation due to horizontal rotation: towards gantry-free radiation therapy by Buckley, J G, Rai, R, Liney, G P, Dowling, J A, Holloway, L C, Metcalfe, P E, Keall, P J

    Published in Physics in medicine & biology (04-09-2019)
    “…Gantry-free radiation therapy systems may be simpler and more cost effective, particularly for MRI-guided photon or hadron therapy. This study aims to…”
    Get more information
    Journal Article
  6. 6

    Technical Note: Experimental results from a prototype high-field inline MRI-linac by Liney, G. P., Dong, B., Begg, J., Vial, P., Zhang, K., Lee, F., Walker, A., Rai, R., Causer, T., Alnaghy, S. J., Oborn, B. M., Holloway, L., Metcalfe, P., Barton, M., Crozier, S., Keall, P.

    Published in Medical physics (Lancaster) (01-09-2016)
    “…Purpose: The pursuit of real-time image guided radiotherapy using optimal tissue contrast has seen the development of several hybrid magnetic resonance imaging…”
    Get full text
    Journal Article
  7. 7

    Radiotherapy beyond cancer: Target localization in real‐time MRI and treatment planning for cardiac radiosurgery by Ipsen, S., Blanck, O., Oborn, B., Bode, F., Liney, G., Hunold, P., Rades, D., Schweikard, A., Keall, P. J.

    Published in Medical physics (Lancaster) (01-12-2014)
    “…Purpose: Atrial fibrillation (AFib) is the most common cardiac arrhythmia that affects millions of patients world‐wide. AFib is usually treated with minimally…”
    Get full text
    Journal Article
  8. 8

    Pelvic organ motion and dosimetric implications during horizontal patient rotation for prostate radiation therapy by Buckley, J. G., Dowling, J. A., Sidhom, M., Liney, G. P., Rai, R., Metcalfe, P. E., Holloway, L. C., Keall, P. J.

    Published in Medical physics (Lancaster) (01-01-2021)
    “…Purpose Gantry‐free radiation therapy systems utilizing patient rotation would be simpler and more cost effective than the conventional gantry‐based systems…”
    Get full text
    Journal Article
  9. 9

    Development of a registration framework to validate MRI with histology for prostate focal therapy by Reynolds, H. M., Williams, S., Zhang, A., Chakravorty, R., Rawlinson, D., Ong, C. S., Esteva, M., Mitchell, C., Parameswaran, B., Finnegan, M., Liney, G., Haworth, A.

    Published in Medical physics (Lancaster) (01-12-2015)
    “…Purpose: Focal therapy has been proposed as an alternative method to whole‐gland treatment for prostate cancer when aiming to reduce treatment side effects…”
    Get full text
    Journal Article
  10. 10

    Quantitative evaluation of diffusion-weighted imaging techniques for the purposes of radiotherapy planning in the prostate by Liney, G P, Holloway, L, Al Harthi, T M, Sidhom, M, Moses, D, Juresic, E, Rai, R, Manton, D J

    Published in British journal of radiology (01-05-2015)
    “…Diffusion-weighted imaging (DWI) is an important technique for the localization of prostate cancer, and its response assessment during treatment with…”
    Get full text
    Journal Article
  11. 11
  12. 12

    Towards real-time MRI-guided 3D localization of deforming targets for non-invasive cardiac radiosurgery by Ipsen, S, Blanck, O, Lowther, N J, Liney, G P, Rai, R, Bode, F, Dunst, J, Schweikard, A, Keall, P J

    Published in Physics in medicine & biology (21-11-2016)
    “…Radiosurgery to the pulmonary vein antrum in the left atrium (LA) has recently been proposed for non-invasive treatment of atrial fibrillation (AF). Precise…”
    Get more information
    Journal Article
  13. 13
  14. 14

    A method to produce and validate a digitally reconstructed radiograph-based computer simulation for optimisation of chest radiographs acquired with a computed radiography imaging system by MOORE, C. S, LINEY, G. P, BEAVIS, A. W, SAUNDERSON, J. R

    Published in British journal of radiology (01-10-2011)
    “…The purpose of this study was to develop and validate a computer model to produce realistic simulated computed radiography (CR) chest images using CT data sets…”
    Get full text
    Journal Article
  15. 15

    Commissioning of a new wide-bore MRI scanner for radiotherapy planning of head and neck cancer by Liney, G P, Owen, S C, Beaumont, A K E, Lazar, V R, Manton, D J, Beavis, A W

    Published in British journal of radiology (01-07-2013)
    “…A combination of CT and MRI is recommended for radiotherapy planning of head and neck cancers, and optimal spatial co-registration is achieved by imaging in…”
    Get full text
    Journal Article
  16. 16
  17. 17

    Quantitative comparison of 3D and 2.5D gamma analysis: introducing gamma angle histograms by Al Sa'd, M, Graham, J, Liney, G P, Moore, C J

    Published in Physics in medicine & biology (21-04-2013)
    “…Comparison of dose distributions using the 3D gamma method is anticipated to provide better indicators for the quality assurance process than the 2.5D (stacked…”
    Get more information
    Journal Article
  18. 18

    TH‐C‐141‐09: A Comparison of MRI Distortion Between Scanners and Sequences for Radiotherapy Purposes by Walker, A, Holloway, L, Liney, G, Metcalfe, P

    Published in Medical Physics (01-06-2013)
    “…Purpose: To quantify the magnitude and distribution of system related geometric distortion present in MR images and determine the clinical radiotherapy sites…”
    Get full text
    Conference Proceeding Journal Article
  19. 19

    Enhanced MRI-guided radiotherapy with gadolinium-based nanoparticles: preclinical evaluation with an MRI-linac by Byrne, H. L., Le Duc, G., Lux, F., Tillement, O., Holmes, N. M., James, A., Jelen, U., Dong, B., Liney, G., Roberts, T. L., Kuncic, Z.

    Published in Cancer nanotechnology (06-10-2020)
    “…Background The AGuIX ® (NH TherAguix) nanoparticle has been developed to enhance radiotherapy treatment and provide strong MR contrast. These two properties…”
    Get full text
    Journal Article
  20. 20