Search Results - "Leitgeb, Rainer A"
-
1
Optical coherence tomography today: speed, contrast, and multimodality
Published in Journal of biomedical optics (2014)“…In the last 25 years, optical coherence tomography (OCT) has advanced to be one of the most innovative and most successful translational optical imaging…”
Get full text
Journal Article -
2
Roadmap on digital holography [Invited]
Published in Optics express (25-10-2021)“…This Roadmap article on digital holography provides an overview of a vast array of research activities in the field of digital holography. The paper consists…”
Get full text
Journal Article -
3
Subaperture correlation based digital adaptive optics for full field optical coherence tomography
Published in Optics express (06-05-2013)“…This paper proposes a sub-aperture correlation based numerical phase correction method for interferometric full field imaging systems provided the complex…”
Get full text
Journal Article -
4
Numerical focusing methods for full field OCT: a comparison based on a common signal model
Published in Optics express (30-06-2014)“…In this paper a theoretical model of the full field swept source (FF SS) OCT signal is presented based on the angular spectrum wave propagation approach which…”
Get full text
Journal Article -
5
Wide Dynamic Range Digital Aberration Measurement and Fast Anterior-Segment OCT Imaging
Published in Sensors (Basel, Switzerland) (10-08-2024)“…Ocular aberrometry with a wide dynamic range for assessing vision performance and anterior segment imaging that provides anatomical details of the eye are both…”
Get full text
Journal Article -
6
Ultra-high-speed volumetric tomography of human retinal blood flow
Published in Optics express (02-03-2009)“…Applying novel detector development based on CMOS technology to Fourier domain optical coherence tomography we achieve depth profile rates up to 200,000…”
Get full text
Journal Article -
7
Visualization of microvasculature by dual-beam phase-resolved Doppler optical coherence tomography
Published in Optics express (17-01-2011)“…We present a dual-beam Doppler optical coherence tomography system for visualizing the microvasculature within the retina. The sample arm beams from two…”
Get full text
Journal Article -
8
Multiple instance learning based classification of diabetic retinopathy in weakly-labeled widefield OCTA en face images
Published in Scientific reports (29-05-2023)“…Diabetic retinopathy (DR), a pathologic change of the human retinal vasculature, is the leading cause of blindness in working-age adults with diabetes…”
Get full text
Journal Article -
9
Measurement of tear film thickness using ultrahigh-resolution optical coherence tomography
Published in Investigative ophthalmology & visual science (15-08-2013)“…To visualize the precorneal tear film with ultrahigh-resolution spectral domain optical coherence tomography, enabling quantification of tear film thickness in…”
Get full text
Journal Article -
10
Digital adaptive optics based on digital lateral shearing of the computed pupil field for point scanning retinal swept source OCT
Published in Biomedical optics express (01-03-2021)“…A novel non-iterative digital adaptive optics technique is presented in which the wavefront error is calculated using the phase difference between the pupil…”
Get full text
Journal Article -
11
Macroscopic fluorescence-lifetime imaging of NADH and protoporphyrin IX improves the detection and grading of 5-aminolevulinic acid-stained brain tumors
Published in Scientific reports (24-11-2020)“…Maximal safe tumor resection remains the key prognostic factor for improved prognosis in brain tumor patients. Despite 5-aminolevulinic acid-based fluorescence…”
Get full text
Journal Article -
12
Live 4D-OCT denoising with self-supervised deep learning
Published in Scientific reports (08-04-2023)“…By providing three-dimensional visualization of tissues and instruments at high resolution, live volumetric optical coherence tomography (4D-OCT) has the…”
Get full text
Journal Article -
13
Reconstruction of visible light optical coherence tomography images retrieved from discontinuous spectral data using a conditional generative adversarial network
Published in Biomedical optics express (01-11-2021)“…Achieving high resolution in optical coherence tomography typically requires the continuous extension of the spectral bandwidth of the light source. This work…”
Get full text
Journal Article -
14
Toward optical coherence tomography on a chip: in vivo three-dimensional human retinal imaging using photonic integrated circuit-based arrayed waveguide gratings
Published in Light, science & applications (05-01-2021)“…In this work, we present a significant step toward in vivo ophthalmic optical coherence tomography and angiography on a photonic integrated chip. The…”
Get full text
Journal Article -
15
Morpho-molecular signal correlation between optical coherence tomography and Raman spectroscopy for superior image interpretation and clinical diagnosis
Published in Scientific reports (11-05-2021)“…The combination of manifold optical imaging modalities resulting in multimodal optical systems allows to discover a larger number of biomarkers than using a…”
Get full text
Journal Article -
16
Scanning protocols dedicated to smart velocity ranging in spectral OCT
Published in Optics express (21-12-2009)“…We introduce a new type of scanning protocols, called segmented protocols, which enable extracting multi-range flow velocity information from a single Spectral…”
Get full text
Journal Article -
17
Speckle noise reduction in high speed polarization sensitive spectral domain optical coherence tomography
Published in Optics express (18-07-2011)“…We present a high speed polarization sensitive spectral domain optical coherence tomography system based on polarization maintaining fibers and two high speed…”
Get full text
Journal Article -
18
In vivo human retinal swept source optical coherence tomography and angiography at 830 nm with a CMOS compatible photonic integrated circuit
Published in Scientific reports (26-10-2021)“…Photonic integrated circuits (PIC) provide promising functionalities to significantly reduce the size and costs of optical coherence tomography (OCT) systems…”
Get full text
Journal Article -
19
Measurement of absolute blood flow velocity and blood flow in the human retina by dual-beam bidirectional Doppler fourier-domain optical coherence tomography
Published in Investigative ophthalmology & visual science (12-09-2012)“…The present experiments were undertaken to evaluate the validity of absolute flow velocity measurements with a dual-beam bidirectional Doppler Fourier-domain…”
Get full text
Journal Article -
20
Key Developments for Partial Coherence Biometry and Optical Coherence Tomography in the Human Eye Made in Vienna
Published in Investigative ophthalmology & visual science (13-07-2016)“…To describe key developments of optical biometry and optical coherence tomography (OCT) for ophthalmic applications made by one of the pioneering research…”
Get full text
Journal Article