Search Results - "Lawry, T J"

  • Showing 1 - 19 results of 19
Refine Results
  1. 1

    One-dimensional pressure transfer models for acoustic–electric transmission channels by Wilt, K.R., Lawry, T.J., Scarton, H.A., Saulnier, G.J.

    Published in Journal of sound and vibration (15-09-2015)
    “…A method for modeling piezoelectric-based ultrasonic acoustic–electric power and data transmission channels is presented. These channels employ piezoelectric…”
    Get full text
    Journal Article
  2. 2

    Computer simulation of MRS localization techniques: an analysis of ISIS by Lawry, T J, Karczmar, G S, Weiner, M W, Matson, G B

    Published in Magnetic resonance in medicine (01-03-1989)
    “…Computer simulations were used to evaluate the ISIS localization technique as implemented with both head and surface coils. The effects of chemical shift, B1…”
    Get more information
    Journal Article
  3. 3

    Computer modeling of surface coil sensitivity by Lawry, T J, Weiner, M W, Matson, G B

    Published in Magnetic resonance in medicine (01-11-1990)
    “…A simple model is presented for the calculation of relative signal-to-noise (S/N) ratios of coils of different sizes and configurations when applied to in vivo…”
    Get more information
    Journal Article
  4. 4

    Application of image-guided surface coil P-31 MR spectroscopy to human liver, heart, and kidney by Matson, G B, Twieg, D B, Karczmar, G S, Lawry, T J, Gober, J R, Valenza, M, Boska, M D, Weiner, M W

    Published in Radiology (01-11-1988)
    “…Localized phosphorus-31 magnetic resonance (MR) spectroscopy in humans has previously been accomplished with surface coils by means of depth-resolved surface…”
    Get more information
    Journal Article
  5. 5

    Detection of motion using B1 gradients by Karczmar, G S, Twieg, D B, Lawry, T J, Matson, G B, Weiner, M W

    Published in Magnetic resonance in medicine (01-05-1988)
    “…An NMR method which makes use of a radiofrequency (RF) field gradient to detect diffusion, perfusion, or flow is demonstrated. The technique is analogous to…”
    Get more information
    Journal Article
  6. 6

    A high-performance ultrasonic system for the simultaneous transmission of data and power through solid metal barriers by Lawry, T. J., Wilt, K. R., Ashdown, J. D., Scarton, H. A., Saulnier, G. J.

    “…This paper presents a system capable of simultaneous high-power and high-data-rate transmission through solid metal barriers using ultrasound. By coaxially…”
    Get full text
    Journal Article
  7. 7

    A full-duplex ultrasonic through-wall communication and power delivery system by Ashdown, J. D., Wilt, K. R., Lawry, T. J., Saulnier, G. J., Shoudy, D. A., Scarton, H. A., Gavens, A. J.

    “…This paper presents a method for two-way ultrasonic communication and power delivery through thick metallic enclosures without physical penetration…”
    Get full text
    Journal Article
  8. 8

    Analytical modeling of a sandwiched plate piezoelectric transformer-based acoustic-electric transmission channel by Lawry, T. J., Wilt, K. R., Scarton, H. A., Saulnier, G. J.

    “…The linear propagation of electromagnetic and dilatational waves through a sandwiched plate piezoelectric transformer (SPPT)-based acoustic-electric…”
    Get full text
    Journal Article
  9. 9

    Penetration-free system for transmission of data and power through solid metal barriers by Lawry, T. J., Saulnier, G. J., Ashdown, J. D., Wilt, K. R., Scarton, H. A., Pascarelle, S., Pinezich, J. D.

    “…This paper presents a novel system capable of simultaneous high-power and high data-rate transmission through solid metal barriers using ultrasound. By…”
    Get full text
    Conference Proceeding
  10. 10

    High-rate ultrasonic communication through metallic barriers using MIMO-OFDM techniques by Ashdown, J. D., Saulnier, G. J., Lawry, T. J., Wilt, K. R., Scarton, H. A.

    “…This paper presents methods to achieve high data transmission rates through metallic barriers using ultrasonic signalling techniques. Due to the frequency…”
    Get full text
    Conference Proceeding
  11. 11

    Use of computer simulations for quantitation of 31P ISIS MRS results by Matson, G B, Meyerhoff, D J, Lawry, T J, Lara, R S, Duijn, J, Deicken, R F, Weiner, M W

    Published in NMR in biomedicine (01-05-1993)
    “…The difficulties in quantitation of in vivo 31P spectra are exacerbated by the fact that, in general, coils with inhomogeneous B1 fields are used with in vivo…”
    Get more information
    Journal Article
  12. 12

    Improvement of the rotating frame experiment by detection of residual Z magnetization: a 31P MRS study of metabolite levels in a Meth-A sarcoma by Karczmar, G S, Shine, N, Lawry, T J, Weiner, M W, Matson, G B

    Published in NMR in biomedicine (01-04-1989)
    “…The radio frequency field (B1) gradient of a surface coil can be used to obtain spectra from a series of sample regions which experience different B1 field…”
    Get more information
    Journal Article
  13. 13

    Multi-channel data communication through thick metallic barriers by Ashdown, J. D., Saulnier, G. J., Lawry, T. J., Wilt, K. R., Scarton, H. A., Pascarelle, S., Pinezich, J. D.

    “…This paper explores the use of multiple communication channels to transmit data at high rates, without physical penetrations, through thick metallic barriers…”
    Get full text
    Conference Proceeding
  14. 14
  15. 15
  16. 16

    Left-right asymmetry in neutrino-produced hadron jets by Ballagh, HC, Bingham, HH, Lawry, TJ, Lys, J, Lynch, GR, Sokoloff, MD, Stevenson, ML, Huson, FR, Schmidt, E, Smart, W, Treadwell, E, Cence, RJ, Harris, FA, Jones, MD, Koide, A, Peters, MW, Peterson, VZ, Lubatti, HJ, Moriyasu, K, Wolin, E, Camerini, U, Fry, W, Gee, D, Gee, M, Loveless, RJ, Reeder, DD

    Published in Physical review. D, Particles and fields (01-11-1989)
    “…In an experiment (E546) to study interactions of {l angle}{ital E}{r angle}=100 GeV and {l angle}{ital Q}{sup 2}{r angle}=17 GeV{sup 2} neutrinos in the…”
    Get full text
    Journal Article
  17. 17
  18. 18
  19. 19