Search Results - "Larson, Erik R"

  • Showing 1 - 15 results of 15
Refine Results
  1. 1

    Scaling the Low-Shear Pulsatile TORVAD for Pediatric Heart Failure by Gohean, Jeffrey R, Larson, Erik R, Hsi, Brian H, Kurusz, Mark, Smalling, Richard W, Longoria, Raul G

    Published in ASAIO journal (1992) (01-03-2017)
    “…This article provides an overview of the design challenges associated with scaling the low-shear pulsatile TORVAD ventricular assist device (VAD) for treating…”
    Get full text
    Journal Article
  2. 2

    Admittance to detect alterations in left ventricular stroke volume by Larson, Erik R., PhD, Porterfield, John E., PhD, Sagar, Sandeep, MD, PhD, Marmol-Velez, Juan, MD, Panday, Manoj, MD, Escobedo, Daniel, Michalek, Joel, PhD, Ouyang, Yongjian, MS, Valvano, Jonathan W., PhD, Pearce, John A., PhD, Feldman, Marc D., MD

    Published in Heart rhythm (01-11-2014)
    “…Background Implantable cardioverter-defibrillators monitor intracardiac electrograms (EGMs) to discriminate between ventricular and supraventricular…”
    Get full text
    Journal Article
  3. 3

    Dynamic correction for parallel conductance, Gp, and gain factor, α, in invasive murine left ventricular volume measurements by PORTERFIELD, John E, KOTTAM, Anil T. G, RAGHAVAN, Karthik, ESCOBEDO, Daniel, JENKINS, James T, LARSON, Erik R, TREVINO, Rodolfo J, VALVANO, Jonathan W, PEARCE, John A, FELDMAN, Marc D

    Published in Journal of applied physiology (1985) (01-12-2009)
    “…The conductance catheter technique could be improved by determining instantaneous parallel conductance (G(P)), which is known to be time varying, and by…”
    Get full text
    Journal Article
  4. 4

    Preload Sensitivity with TORVAD Counterpulse Support Prevents Suction and Overpumping by Gohean, Jeffrey R., Larson, Erik R., Longoria, Raul G., Kurusz, Mark, Smalling, Richard W.

    Published in Cardiovascular engineering and technology (01-09-2019)
    “…Purpose This study compares preload sensitivity of continuous flow (CF) VAD support to counterpulsation using the Windmill toroidal VAD (TORVAD). The TORVAD is…”
    Get full text
    Journal Article
  5. 5

    Analysis of the Spatial Sensitivity of Conductance/Admittance Catheter Ventricular Volume Estimation by Larson, Erik R., Feldman, Marc D., Valvano, Jonathan W., Pearce, John A.

    “…Conductance catheters are known to have a nonuniform spatial sensitivity due to the distribution of the electric field. The Geselowitz relation is applied to…”
    Get full text
    Journal Article
  6. 6

    Preservation of Native Aortic Valve Flow and Full Hemodynamic Support with the TORVAD Using a Computational Model of the Cardiovascular System by Gohean, Jeffrey R, George, Mitchell J, Chang, Kay-Won, Larson, Erik R, Pate, Thomas D, Kurusz, Mark, Longoria, Raul G, Smalling, Richard W

    Published in ASAIO journal (1992) (01-05-2015)
    “…This article describes the stroke volume selection and operational design for the toroidal ventricular assist device (TORVAD), a synchronous,…”
    Get full text
    Journal Article
  7. 7

    Left ventricular epicardial admittance measurement for detection of acute LV dilation by PORTERFIELD, John E, LARSON, Erik R, JENKINS, James T, ESCOBEDO, Daniel, VALVANO, Jonathan W, PEARCE, John A, FELDMAN, Marc D

    Published in Journal of applied physiology (1985) (01-03-2011)
    “…There are two implanted heart failure warning systems incorporated into biventricular pacemakers/automatic implantable cardiac defibrillators and tested in…”
    Get full text
    Journal Article
  8. 8
  9. 9

    A bio-telemetric device for measurement of left ventricular pressure-volume loops using the admittance technique in conscious, ambulatory rats by Raghavan, Karthik, Feldman, Marc D, Porterfield, John E, Larson, Erik R, Jenkins, J Travis, Escobedo, Daniel, Pearce, John A, Valvano, Jonathan W

    Published in Physiological measurement (01-06-2011)
    “…This paper presents the design, construction and testing of a device to measure pressure-volume loops in the left ventricle of conscious, ambulatory rats…”
    Get more information
    Journal Article
  10. 10

    Application of the Geselowitz relationship to the murine conductance catheter by Larson, E. R., Pearce, J. A.

    “…Conductance catheters are known to have a nonuniform spatial sensitivity due to the distribution of the electric field. The Geselowitz relation is applied to…”
    Get full text
    Conference Proceeding Journal Article
  11. 11

    Accuracy considerations in catheter based estimation of left ventricular volume by Pearce, J A, Porterfield, J E, Larson, E R, Valvano, J W, Feldman, M D

    “…Cardiac volume estimation in the Left Ventricle from impedance or admittance measurement is subject to two major sources of error: parallel current pathways in…”
    Get full text
    Conference Proceeding Journal Article
  12. 12
  13. 13
  14. 14
  15. 15

    Embedded Medical Devices: Pressure Volume Loops in Rodents by Loeffler, K., Porterfield, J. E., Larson, E. R., Escobedo, D., Escobar, G. P., Feldman, M. D., Valvano, J. W.

    Published in IEEE potentials (01-01-2013)
    “…Man has been instrumenting the human body with electrical devices since the early 1800s. McWilliam built an electrical stimulator of the heart in 1889. In the…”
    Get full text
    Journal Article