Search Results - "Larsen, Lars Hauer"

  • Showing 1 - 19 results of 19
Refine Results
  1. 1

    Determination of ultra‐low oxygen concentrations in oxygen minimum zones by the STOX sensor by Revsbech, Niels Peter, Larsen, Lars Hauer, Gundersen, Jens, Dalsgaard, Tage, Ulloa, Osvaldo, Thamdrup, Bo

    Published in Limnology and oceanography, methods (01-05-2009)
    “…The methods used until now have not been able to reliably resolve O2 concentrations in oceanic oxygen minimum zones below 1–2 µmol L−1. We present a new…”
    Get full text
    Journal Article
  2. 2

    Kinetics, diffusional limitation and microscale distribution of chemistry and organisms in a CANON reactor by Nielsen, Michael, Bollmann, Annette, Sliekers, Olav, Jetten, Mike, Schmid, Markus, Strous, Marc, Schmidt, Ingo, Larsen, Lars Hauer, Nielsen, Lars Peter, Revsbech, Niels Peter

    Published in FEMS microbiology ecology (2005)
    “…In the Completely Autotrophic Nitrogen removal Over Nitrite (CANON) process, aerobic and anaerobic ammonia oxidizing bacteria cooperate to remove ammonia in…”
    Get full text
    Journal Article
  3. 3

    Bacterium-Based NO2− Biosensor for Environmental Applications by Nielsen, Michael, Larsen, Lars Hauer, Jetten, Mike S M, Revsbech, Niels Peter

    Published in Applied and Environmental Microbiology (01-11-2004)
    “…Classifications Services AEM Citing Articles Google Scholar PubMed Related Content Social Bookmarking CiteULike Delicious Digg Facebook Google+ Mendeley Reddit…”
    Get full text
    Journal Article
  4. 4

    Biosensor Determination of the Microscale Distribution of Nitrate, Nitrate Assimilation, Nitrification, and Denitrification in a Diatom-Inhabited Freshwater Sediment by LORENZEN, J, LARSEN, L. H, KJAER, T, REVSBECH, N.-P

    Published in Applied and Environmental Microbiology (01-09-1998)
    “…Classifications Services AEM Citing Articles Google Scholar PubMed Related Content Social Bookmarking CiteULike Delicious Digg Facebook Google+ Mendeley Reddit…”
    Get full text
    Journal Article
  5. 5

    Microscale Biosensor for Measurement of Volatile Fatty Acids in Anoxic Environments by MEYER, Rikke Louise, LARSEN, Lars Hauer, REVSBECH, Niels Peter

    Published in Applied and Environmental Microbiology (01-03-2002)
    “…Classifications Services AEM Citing Articles Google Scholar PubMed Related Content Social Bookmarking CiteULike Delicious Digg Facebook Google+ Mendeley Reddit…”
    Get full text
    Journal Article
  6. 6

    Amperometic microsensor for measurement of gaseous and dissolved CO2 by Revsbech, Niels Peter, Garcia-Robledo, Emilio, Sveegaard, Steffen, Andersen, Mikkel Holmen, Gothelf, Kurt Vesterager, Larsen, Lars Hauer

    Published in Sensors and actuators. B, Chemical (15-03-2019)
    “…•A new type of electrochemical CO2 microsensor is described.•A tip O2 trap compartment enables CO2 analysis by cathodic reduction without interference from…”
    Get full text
    Journal Article
  7. 7

    Hydrogen microsensors with hydrogen sulfide traps by Nielsen, Michael, Larsen, Lars Hauer, Ottosen, Lars Ditlev Mørck, Revsbech, Niels Peter

    Published in Sensors and actuators. B, Chemical (01-08-2015)
    “…Hydrogen is often formed in sulfidic environments where interference from hydrogen sulfide has prevented its analysis by amperometric hydrogen microsensors…”
    Get full text
    Journal Article
  8. 8

    Pericellular oxygen depletion during ordinary tissue culturing, measured with oxygen microsensors by Pettersen, Erik O., Larsen, Lars Hauer, Ramsing, Niels Birger, Ebbesen, Peter

    Published in Cell proliferation (01-08-2005)
    “…  Recent research has found important differences in oxygen tension in proximity to certain mammalian cells when grown in culture. Oxygen has a low diffusion…”
    Get full text
    Journal Article
  9. 9

    Structure and function of a nitrifying biofilm as determined by in situ hybridization and the use of microelectrodes by SCHRAMM, A, HAUER LARSEN, L, REVSBECH, N. P, BIRGER RAMSING, N, AMANN, R, SCHLEIFER, K.-H

    Published in Applied and Environmental Microbiology (01-12-1996)
    “…Services AEM Citing Articles Google Scholar PubMed Related Content Social Bookmarking CiteULike Delicious Digg Facebook Google+ Mendeley Reddit StumbleUpon…”
    Get full text
    Journal Article
  10. 10

    A Microscale NO3 - Biosensor for Environmental Applications by Larsen, Lars Hauer, Kjær, Thomas, Revsbech, Niels Peter

    Published in Analytical chemistry (Washington) (01-09-1997)
    “…A biosensor for NO3 - containing immobilized dentrifying bacteria and a reservoir of liquid growth medium for the bacteria was constructed. The bacteria did…”
    Get full text
    Journal Article
  11. 11

    Bacterium-Based NO sub(2) super(-) Biosensor for Environmental Applications by Nielsen, Michael, Larsen, Lars Hauer, Jetten, Mike SM, Revsbech, Niels Peter

    Published in Applied and environmental microbiology (01-11-2004)
    “…A sensitive NO sub(2) super(-) biosensor that is based on bacterial reduction of NO sub(2) super(-) to N sub(2)O and subsequent detection of the N sub(2)O by a…”
    Get full text
    Journal Article
  12. 12

    Bacterium-based NO-2 biosensor for environmental applications by NIELSEN, Michael, LARSEN, Lars Hauer, JETTEN, Mike S. M, REVSBECH, Niels Peter

    Published in Applied and environmental microbiology (01-11-2004)
    “…ABSTRACT A sensitive NO 2 − biosensor that is based on bacterial reduction of NO 2 − to N 2 O and subsequent detection of the N 2 O by a built-in…”
    Get full text
    Journal Article
  13. 13

    Microsensor for in situ flow measurements in benthic boundary layers at submillimeter resolution with extremely slow flow by Brand, Andreas, Müller, Beat, Wüest, Alfred, Dinkel, Christian, Revsbech, Niels Peter, Nielsen, Lars Peter, Pedersen, Ole, Damgaard, Lars Riis, Larsen, Lars Hauer, Wehrli, Bernhard

    Published in Limnology and oceanography, methods (01-06-2007)
    “…The currents in the lowest few millimeters of the bottom boundary layer of lakes are highly important for the dissipation of kinetic energy and for chemical…”
    Get full text
    Journal Article
  14. 14

    Fast responding biosensor for on-line determination of nitrate/nitrite in activated sludge by Larsen, Lars Hauer, Damgaard, Lars Riis, Kjær, Thomas, Stenstrøm, Theiss, Lynggaard-Jensen, Anders, Revsbech, Niels Peter

    Published in Water research (Oxford) (15-06-2000)
    “…A microscale biosensor for nitrate/nitrite was used for in-situ monitoring in an activated sludge plant. The biosensor is based on diffusion of nitrate/nitrite…”
    Get full text
    Journal Article
  15. 15

    Sensitivity control of ion-selective biosensors by electrophoretically mediated analyte transport by Kjær, Thomas, Hauer Larsen, Lars, Revsbech, Niels-Peter

    Published in Analytica chimica acta (26-05-1999)
    “…We present a new method for changing the sensitivity of any microsensor that functions by converting an ion into an uncharged molecule which is subsequently…”
    Get full text
    Journal Article
  16. 16
  17. 17

    Microsensor for in-situ flow measurements in benthic boundary layers at sub-millimeter resolution with extremely slow flow by Brand, Andreas, Mueller, Beat, Wueest, Alfred, Dinkel, Christian, Revsbech, Niels Peter, Nielsen, Lars Peter, Pedersen, Ole, Damgaard, Lars Riis, Larsen, Lars Hauer, Wehrli, Bernhard

    Published in Limnology and oceanography, methods (01-01-2007)
    “…The currents in the lowest few mm of the bottom boundary layer of lakes are highly important for the dissipation of kinetic energy and for chemical processes…”
    Get full text
    Journal Article
  18. 18

    A microsensor for nitrate based on immobilized denitrifying bacteria by Larsen, L.H. (University of Aarhus, Aarhus, Denmark.), Revsbech, N.P, Binnerup, S.J

    Published in Applied and Environmental Microbiology (01-04-1996)
    “…A biosensor for NO3(-) was constructed by attaching a 30- to 70-micrometer-wide capillary with immobilized denitrifying bacteria in front of an N2O…”
    Get full text
    Journal Article
  19. 19

    Microscale biosensors for environmental monitoring by Damgaard, Lars Riis, Larsen, Lars Hauer, Revsbech, Niels Peter

    “…Microbiosensors for nitrate and methane have been constructed with diameters down to 30 μm. Both sensors are characterized by linear responses to their…”
    Get full text
    Journal Article