Search Results - "Lambert, Jamil"
-
1
Relating Linear Energy Transfer to the Formation and Resolution of DNA Repair Foci After Irradiation with Equal Doses of X-ray Photons, Plateau, or Bragg-Peak Protons
Published in International journal of molecular sciences (28-11-2018)“…Proton beam therapy is increasingly applied for the treatment of human cancer, as it promises to reduce normal tissue damage. However, little is known about…”
Get full text
Journal Article -
2
Thermoacoustic range verification during pencil beam delivery of a clinical plan to an abdominal imaging phantom
Published in Radiotherapy and oncology (01-06-2021)“…•Fast (4-6 us) and stress-confined, delivery enables thermoacoustic range verification.•Submillimeter range accuracy was achieved for beamlets that delivered…”
Get full text
Journal Article -
3
A prototype scintillation dosimeter customized for small and dynamic megavoltage radiation fields
Published in Physics in medicine & biology (21-02-2010)“…A prototype plastic scintillation dosimeter has been developed with a small sensitive volume, rapid response and good dosimetric performance. The novelty of…”
Get more information
Journal Article -
4
Clinical Trials of a Urethral Dose Measurement System in Brachytherapy Using Scintillation Detectors
Published in International journal of radiation oncology, biology, physics (01-02-2011)“…Purpose To report on the clinical feasibility of a novel scintillation detector system with fiberoptic readout that measures the urethral dose during…”
Get full text
Journal Article -
5
In vivo dosimeters for HDR brachytherapy: A comparison of a diamond detector, MOSFET, TLD, and scintillation detector
Published in Medical physics (Lancaster) (01-05-2007)“…The large dose gradients in brachytherapy necessitate a detector with a small active volume for accurate dosimetry. The dosimetric performance of a novel…”
Get full text
Journal Article -
6
128 Impact of biological response-based adaptive radiotherapy on doses to swallowing OARS in modelled IMPT plans
Published in Radiotherapy and oncology (01-03-2024)“…The PEARL study is a phase 2 multi-centre trial for good prognosis HPV-associated oropharyngeal squamous cell carcinoma (OPSCC) patients, currently open in the…”
Get full text
Journal Article -
7
Real-time brachytherapy dosimetry: Clinical application of a plastic scintillation dosimeter
Published in Brachytherapy (2008)Get full text
Journal Article -
8
Out-of-field dosimetry and 2nd cancer risk assessment of child patients under proton therapy using a TLD-based microdosimeter
Published in Radiation measurements (01-11-2017)Get full text
Journal Article -
9
Hippocampal sparing radiotherapy in adults with primary brain tumours: a comparative planning and dosimetric study using IMPT, IMRT and 3DCRT
Published in Neuro-oncology (Charlottesville, Va.) (12-10-2019)“…Abstract Introduction We assessed the feasibility of hippocampal sparing in adults with primary brain tumours using Intensity Modulated Proton Therapy (IMPT)…”
Get full text
Journal Article -
10
Daily QA in proton therapy using a single commercially available detector
Published in Journal of applied clinical medical physics (08-11-2014)“…We present here a novel method for using a single device in the daily quality assurance (QA) of pencil beam scanning (PBS) proton beams and an improved method…”
Get full text
Journal Article -
11
Evaluation of detectors for acquisition of pristine depth‐dose curves in pencil beam scanning
Published in Journal of applied clinical medical physics (08-11-2015)“…Acquisition of quasi‐monoenergetic ("pristine") depth‐dose curves is an essential task in the frame of commissioning and quality assurance of a proton therapy…”
Get full text
Journal Article -
12
Cerenkov light spectrum in an optical fiber exposed to a photon or electron radiation therapy beam
Published in Applied optics. Optical technology and biomedical optics (20-06-2009)“…A Cerenkov signal is generated when energetic charged particles enter the core of an optical fiber. The Cerenkov intensity can be large enough to interfere…”
Get more information
Journal Article -
13
EVALUATION OF AN ELECTRONIC PORTAL IMAGER FOR IMRT QA
Published in Australasian physical & engineering sciences in medicine (01-12-2008)“…The treatment planning system, Eclipse version 7.3.10, was configured to have the Portal Dose Image Prediction (PDIP) algorithm version 7.5.18.0 and Pencil…”
Get full text
Journal Article -
14
Large Core Fibers for Short-Distance Communication in Radiation Fields
Published in COIN-ACOFT 2007 - Joint International Conference on the Optical Internet and the 32nd Australian Conference on Optical Fibre Technology (01-06-2007)“…The intensity of Čerenkov radiation transmitted along a step index, a graded index and an air core polymer optical fiber are compared. It is demonstrated that…”
Get full text
Conference Proceeding -
15
A fibre optic dosimeter for prostate cancer therapy
Published in ACOFT/AOS 2006 - Australian Conference on Optical Fibre Technology/Australian Optical Society (01-07-2006)“…Comparative measurements of the performance of a fibre optic dosimeter designed for prostate cancer therapy, a MOSFET and diamond detector are presented. The…”
Get full text
Conference Proceeding