Search Results - "Lagore, Russell L"
-
1
Feasibility of using toroidal transceivers for acquiring intraoperative MR images around deep brain stimulation electrodes
Published in NeuroImage (Orlando, Fla.) (15-11-2024)“…•Imaging with a DBS electrode inductively coupled to a toroidal transceiver.•Reduced RF artifact, scan time and improved SNR near the DBS electrode.•Accurate…”
Get full text
Journal Article -
2
Ultra-high field (10.5 T) resting state fMRI in the macaque
Published in NeuroImage (Orlando, Fla.) (01-12-2020)“…Resting state functional connectivity refers to the temporal correlations between spontaneous hemodynamic signals obtained using functional magnetic resonance…”
Get full text
Journal Article -
3
Ultra-high field (10.5T) diffusion-weighted MRI of the macaque brain
Published in NeuroImage (Orlando, Fla.) (15-07-2022)“…Diffu0sion-weighted magnetic resonance imaging (dMRI) is a non-invasive imaging technique that provides information about the barriers to the diffusion of…”
Get full text
Journal Article -
4
In vivo human head MRI at 10.5T: A radiofrequency safety study and preliminary imaging results
Published in Magnetic resonance in medicine (01-07-2020)“…Purpose The purpose of this study is to safely acquire the first human head images at 10.5T. Methods To ensure safety of subjects, we validated the…”
Get full text
Journal Article -
5
First in‐vivo human imaging at 10.5T: Imaging the body at 447 MHz
Published in Magnetic resonance in medicine (01-07-2020)“…Purpose To investigate the feasibility of imaging the human torso and to evaluate the performance of several radiofrequency (RF) management strategies at…”
Get full text
Journal Article -
6
An 8‐dipole transceive and 24‐loop receive array for non‐human primate head imaging at 10.5 T
Published in NMR in biomedicine (01-04-2021)“…A 32‐channel RF coil was developed for brain imaging of anesthetized non‐human primates (rhesus macaque) at 10.5 T. The coil is composed of an 8‐channel dipole…”
Get full text
Journal Article -
7
RF coil design strategies for improving SNR at the ultrahigh magnetic field of 10.5T
Published in Magnetic resonance in medicine (16-10-2024)“…Toward pushing the boundaries of ultrahigh fields for human brain imaging, we wish to evaluate experimentally achievable SNR relative to ultimate intrinsic SNR…”
Get full text
Journal Article -
8
Improving radiofrequency power and specific absorption rate management with bumped transmit elements in ultra‐high field MRI
Published in Magnetic resonance in medicine (01-12-2020)“…Purpose In this study, we investigate a strategy to reduce the local specific absorption rate (SAR) while keeping B1+ constant inside the region of interest…”
Get full text
Journal Article -
9
Toward imaging the body at 10.5 tesla
Published in Magnetic resonance in medicine (01-01-2017)“…Purpose To explore the potential of performing body imaging at 10.5 Tesla (T) compared with 7.0T through evaluating the transmit/receive performance of…”
Get full text
Journal Article -
10
A self‐decoupled 32‐channel receive array for human‐brain MRI at 10.5 T
Published in Magnetic resonance in medicine (01-09-2021)“…Purpose Receive array layout, noise mitigation, and B0 field strength are crucial contributors to SNR and parallel‐imaging performance. Here, we investigate…”
Get full text
Journal Article -
11
In vivo MR imaging with simultaneous RF transmission and reception
Published in Magnetic resonance in medicine (01-12-2016)“…Purpose To present a practical scheme of a simultaneous radiofrequency (RF) transmit (Tx) and receive (Rx) (STAR) system for MRI, discuss the challenges and…”
Get full text
Journal Article -
12
Radiofrequency heating studies on anesthetized swine using fractionated dipole antennas at 10.5 T
Published in Magnetic resonance in medicine (01-01-2018)“…Purpose To validate electromagnetic and thermal simulations with in vivo temperature measurements, and to demonstrate a framework that can be used to predict…”
Get full text
Journal Article -
13
Investigating the physiological effects of 10.5 Tesla static field exposure on anesthetized swine
Published in Magnetic resonance in medicine (01-01-2018)“…Purpose In this work, we investigated the relative effects of static magnetic field exposure (10.5 Tesla [T]) on two physiological parameters; blood pressure…”
Get full text
Journal Article -
14
A system for automated noise parameter measurements on MR preamplifiers and application to high B0 fields
Published in NMR in biomedicine (01-08-2014)“…A noise figure and noise parameter measurement system was developed that consists of a combination spectrum and network analyzer, preamplifier, programmable…”
Get full text
Journal Article -
15
Electromagnetic Modeling of High-Channel Count Head Receiver Arrays for ultra-High Field MRI
Published in 2021 International Conference on Electromagnetics in Advanced Applications (ICEAA) (09-08-2021)“…Electromagnetic simulations of ultra-high field receive coil arrays featuring 32, 64, and 128 channels are currently being performed to support of head imaging…”
Get full text
Conference Proceeding -
16
-
17
Changes in tissue sodium concentration and sodium relaxation times during the maturation of human knee cartilage: Ex vivo 23Na MRI study at 10.5T
Published in Magnetic resonance in medicine (01-03-2024)“…PurposeTo evaluate the influence of skeletal maturation on sodium (23Na) MRI relaxation parameters and the accuracy of tissue sodium concentration (TSC)…”
Get full text
Journal Article -
18
Changes in tissue sodium concentration and sodium relaxation times during the maturation of human knee cartilage: Ex vivo 23 Na MRI study at 10.5 T
Published in Magnetic resonance in medicine (01-03-2024)“…To evaluate the influence of skeletal maturation on sodium ( Na) MRI relaxation parameters and the accuracy of tissue sodium concentration (TSC) quantification…”
Get full text
Journal Article -
19
Changes in tissue sodium concentration and sodium relaxation times during the maturation of human knee cartilage: Ex vivo 23Na MRI study at 10.5 T
Published in Magnetic resonance in medicine (01-03-2024)“…Purpose To evaluate the influence of skeletal maturation on sodium (23Na) MRI relaxation parameters and the accuracy of tissue sodium concentration (TSC)…”
Get full text
Journal Article -
20
Design considerations for dipole for head MRI at 10.5T
Published in 2015 IEEE MTT-S 2015 International Microwave Workshop Series on RF and Wireless Technologies for Biomedical and Healthcare Applications (IMWS-BIO) (01-09-2015)“…As the world's first 10.5T whole body human MRI scanner is ready for discoveries on new research frontiers, RF challenges need to be overcome to fully realize…”
Get full text
Conference Proceeding