Search Results - "Lagares, J. I."
-
1
Ionization chamber dosimetry of small photon fields: a Monte Carlo study on stopping-power ratios for radiosurgery and IMRT beams
Published in Physics in medicine & biology (21-07-2003)“…Absolute dosimetry with ionization chambers of the narrow photon fields used in stereotactic techniques and IMRT beamlets is constrained by lack of electron…”
Get more information
Journal Article -
2
SU‐E‐T‐391: Modelling Peripheral Photon Dose in TomoTherapy Treatments
Published in Medical Physics (01-06-2012)“…Purpose: The delivery of the therapeutic radiation dose to the tumour in photon radiotherapy, also implies dose deposition in distant organs (peripheral dose)…”
Get full text
Conference Proceeding Journal Article -
3
A new online detector for estimation of peripheral neutron equivalent dose in organ
Published in Medical physics (Lancaster) (01-11-2014)“…Purpose: Peripheral dose in radiotherapy treatments represents a potential source of secondary neoplasic processes. As in the last few years, there has been a…”
Get full text
Journal Article -
4
The wall correction factor for a spherical ionization chamber used in brachytherapy source calibration
Published in Physics in medicine & biology (21-12-2003)“…The effect of wall chamber attenuation and scattering is one of the most important corrections that must be determined when the linear interpolation method…”
Get more information
Journal Article -
5
Estimation of neutron-equivalent dose in organs of patients undergoing radiotherapy by the use of a novel online digital detector
Published in Physics in medicine & biology (07-10-2012)“…Neutron peripheral contamination in patients undergoing high-energy photon radiotherapy is considered as a risk factor for secondary cancer induction…”
Get more information
Journal Article -
6
Neutron spectra around a tandem linear accelerator in the generation of (18)F with a bonner sphere spectrometer
Published in Applied radiation and isotopes (01-08-2016)“…A Bonner sphere spectrometer was used to measure the neutron spectra produced at the collision of protons with an H2(18)O target at different angles. A unique…”
Get full text
Journal Article -
7
Point Detector Scorer in GAMOS/Geant4
Published in IEEE Nuclear Science Symposuim & Medical Imaging Conference (01-10-2010)“…This paper presents the implementation of the Point Detector Scorer in the Monte Carlo simulation code GAMOS/Geant4. The Point Detector Scorer (PDS) is…”
Get full text
Conference Proceeding -
8
MO‐E‐T‐617‐01: Energy and Intensity Modulated Electron Radiation Therapy Using a Monte Carlo Optimization Procedure
Published in Medical physics (Lancaster) (01-06-2005)“…Purpose: This study investigates the potential benefit of energy‐ and intensity‐modulated electron radiotherapy (MERT) for superficial treatments and the…”
Get full text
Journal Article -
9
SU-F-J-99: Dose Accumulation and Evaluation in Lung SBRT Among All Phases of Respiration
Published in Medical physics (Lancaster) (01-06-2016)“…Purpose: To calculate the total planning dose on lung tumors (GTV) by accumulating the dose received in all respiration phases. Methods: A patient 4D planning…”
Get full text
Journal Article -
10
GAMOS: An easy and flexible way to use GEANT4
Published in 2011 IEEE Nuclear Science Symposium Conference Record (01-10-2011)“…The wide range of physics models available in GEANT4, as well as its outstanding geometry and visualization tools, has made it gain widespread use in several…”
Get full text
Conference Proceeding -
11
Anew physics model for the charged particle transport with Geant4
Published in 2011 IEEE Nuclear Science Symposium Conference Record (01-10-2011)“…An accurate modeling of the interactions of charged particles (protons, 2 H, 3 H, 3 He, α-particles...) with energies up to tenths of MeV is necessary for many…”
Get full text
Conference Proceeding -
12
An EGSnrc Monte Carlo study of the microionization chamber for reference dosimetry of narrow irregular IMRT beamlets
Published in Medical physics (Lancaster) (01-09-2004)“…Intensity modulated radiation therapy (IMRT) has evolved toward the use of many small radiation fields, or “beamlets,” to increase the resolution of the…”
Get full text
Journal Article -
13
Routine IMRT verification by means of an automated Monte Carlo simulation system
Published in International journal of radiation oncology, biology, physics (01-05-2003)“…A tool to simulate complete intensity-modulated radiation therapy (IMRT) treatments with the Monte Carlo (MC) method has been developed. This application is…”
Get more information
Journal Article -
14
Micro ionization chamber dosimetry in IMRT verification: Clinical implications of dosimetric errors in the PTV
Published in Radiotherapy and oncology (01-06-2005)“…Absolute dose measurements for Intensity Modulated Radiotherapy (IMRT) beamlets is difficult due to the lack of lateral electron equilibrium. Recently we found…”
Get full text
Journal Article -
15
MLC leaf width impact on the clinical dose distribution: a Monte Carlo approach
Published in International journal of radiation oncology, biology, physics (01-08-2004)“…The influence of the multileaf collimator (MLC) leaf width on the dose distribution in patients treated with conformal radiotherapy and intensity-modulated…”
Get more information
Journal Article -
16
Microionization chamber for reference dosimetry in IMRT verification: clinical implications on OAR dosimetric errors
Published in Physics in medicine & biology (07-03-2005)“…Intensity modulated radiotherapy (IMRT) has become a treatment of choice in many oncological institutions. Small fields or beamlets with sizes of 1 to 5 cm2…”
Get more information
Journal Article -
17
Total skin electron therapy treatment verification: Monte Carlo simulation and beam characteristics of large non-standard electron fields
Published in Physics in medicine & biology (07-09-2003)“…Total skin electron therapy (TSET) is a complex technique which requires non-standard measurements and dosimetric procedures. This paper investigates an…”
Get more information
Journal Article