Search Results - "Kux, A."

Refine Results
  1. 1

    Rapid-thermal oxidized porous Si-The superior photoluminescent Si by PETROVA-KOCH, V, MUSCHIK, T, KUX, A, MEYER, B. K, KOCH, F, LEHMANN, V

    Published in Applied physics letters (24-08-1992)
    “…To improve the stability of porous Si (PS) prepared by electrochemical etching, we make use of rapid-thermal oxidation (RTO). During RTO processing, the…”
    Get full text
    Journal Article
  2. 2

    Time-delayed luminescence from oxidized porous silicon after ultraviolet excitation by Kux, A., Kovalev, D., Koch, F.

    Published in Applied physics letters (02-01-1995)
    “…Oxidized porous silicon is known to luminesce efficiently and with a ns-fast response in the green-blue region of the spectrum (2.3–2.7 eV) at room…”
    Get full text
    Journal Article
  3. 3

    Slow luminescence from trapped charges in oxidized porous silicon by Kux, A., Kovalev, D., Koch, F.

    Published in Thin solid films (01-01-1995)
    “…Porous silicon exhibits a fast (~ l ns) luminescence band in the blue-green (2.3–2.7 eV) spectral region when post-treated by rapid thermal oxidation. In…”
    Get full text
    Journal Article Conference Proceeding
  4. 4

    Red, green and blue luminescence in porous silicon—a study of excitation spectra by Kux, A, Chorin, M.Ben

    Published in Thin solid films (15-04-1996)
    “…Photoluminescence excitation spectra of red-emitting porous silicon show a quadratic rise with excitation energy, reminiscent of indirect absorption and…”
    Get full text
    Journal Article Conference Proceeding
  5. 5

    Charge trapping in ONO interpoly dielectric of FLOTOX EEPROM cells by Brücklmeier, E., Kux, A., Kakoschke, R., Palm, H.

    Published in Microelectronic engineering (1999)
    “…The threshold voltage loss of erased FLOTOX EEPROM cells with various ONO interpoly dielectric layers has been studied as a function of bake time and…”
    Get full text
    Journal Article Conference Proceeding
  6. 6

    Polarization of porous silicon photoluminescence: alignment and built-in anisotropy by Kovalev, D, Ben Chorin, M, Diener, J, Koch, F, Kux, A, Efros, Al.L, Rosen, M, Gippius, N.A, Tikhodeev, S.G

    Published in Thin solid films (15-04-1996)
    “…We report the observation of the anisotropy of the polarization properties of the porous Si photoluminescence. In the edge excitation geometry (exciting light…”
    Get full text
    Journal Article Conference Proceeding
  7. 7

    InterChip via technology for vertical system integration by Ramm, P., Bonfert, D., Gieser, H., Haufe, J., Iberl, F., Klumpp, A., Kux, A., Wieland, R.

    “…Vertical System Integration VSI(R) means the realization of three-dimensional integrated systems by thinning, stacking and vertical interchip wiring of…”
    Get full text
    Conference Proceeding
  8. 8

    Gas Sensing Properties of Porous Silicon by Schechter, Israel, Ben-Chorin, Moshe, Kux, Andreas

    Published in Analytical chemistry (Washington) (01-10-1995)
    “…A study examined the conductivity of porous silicon layers for organic vapor sensing. A many orders of magnitude increase in conductivity in response to a…”
    Get full text
    Journal Article
  9. 9
  10. 10

    Adsorbate effects on photoluminescence and electrical conductivity of porous silicon by Ben-Chorin, Moshe, Kux, Andreas, Schechter, Israel

    Published in Applied physics letters (24-01-1994)
    “…Porous silicon (p type) has been exposed to several chemical vapors at various partial pressures. The quenching of the photoluminescence by the adsorbates has…”
    Get full text
    Journal Article
  11. 11

    New option for balloon recanalization of total coronary occlusions by Höpp, H W, Franzen, D, Deutsch, H J, Kux, A, Hilger, H H

    “…In 9 out of 12 patients with a total coronary occlusion but definite signs of viable myocardium a new approach for the recanalization procedure was…”
    Get more information
    Journal Article
  12. 12

    Correlation between optical properties and crystallite size in porous silicon by LEHMANN, V, JOBST, B, MUSCHIK, T, KUX, A, PETROVA-KOCH, V

    Published in Japanese Journal of Applied Physics (01-05-1993)
    “…Recently a quantum size effect was proposed to be responsible for the blue shift of optical absorption edge and photoluminescence peak wavelength as well as…”
    Get full text
    Journal Article
  13. 13

    Novel model for cell - system interaction (MCSI) in NAND Flash by Friederich, C., Hayek, J., Kux, A., Muller, T., Chan, N., Kobernik, G., Specht, M., Richter, D., Schmitt-Landsiedel, D.

    “…For the first time a stochastic model of the program operation in NAND flash memories is proposed. The model incorporates intrinsic noise effects on the…”
    Get full text
    Conference Proceeding
  14. 14

    Antibodies to p24 antigen do not specifically detect HIV-infected lymphocytes in AIDS patients by Kux, Antje, Bertram, Sylvia, Hufert, Frank T., Schmitz, Herbert, Laer, Dorothee von

    Published in Journal of immunological methods (27-05-1996)
    “…A flow cytometric assay (FCA), which detects the p24 antigen in HIV-infected cell lines and in peripheral blood mononuclear cells (PBMC) of AIDS patients, has…”
    Get full text
    Journal Article
  15. 15

    Phosphodiesterase III inhibition or adrenoreceptor stimulation: milrinone as an alternative to dobutamine in the treatment of severe heart failure by Mager, G, Klocke, R K, Kux, A, Höpp, H W, Hilger, H H

    Published in The American heart journal (01-06-1991)
    “…High levels of endogenous plasma catecholamines in patients with severe congestive heart failure induce a down-regulation of the myocardial…”
    Get more information
    Journal Article
  16. 16

    Effects of a twenty-four-hour milrinone infusion in patients with severe heart failure and cardiogenic shock as a function of the hemodynamic initial condition by Klocke, R K, Mager, G, Kux, A, Höpp, H W, Hilger, H H

    Published in The American heart journal (01-06-1991)
    “…The systemic and pulmonary arterial hemodynamics of 40 patients with severe congestive heart failure were determined during a 24-hour infusion of milrinone…”
    Get more information
    Journal Article
  17. 17
  18. 18
  19. 19

    Hemodynamics and differentiated CO transfer following fulminant lung embolism and pulmonary artery embolectomy and following recurrent lung embolism by Kux, A, Klocke, R K, Pöhler, E, Mager, G, Tauchert, M, Hügel, W, Hilger, H H

    Published in Medizinische Klinik (München. 1983) (15-06-1990)
    “…Pulmonary embolectomy as an emergent surgical treatment after massive pulmonary embolism often is necessary in cardiogenic shock (CS) and even without previous…”
    Get more information
    Journal Article
  20. 20