Search Results - "Kudrna, P"
-
1
Magnesium-silver cathodes for efficient charge injection into Organic Light Emitting Diodes deposited by LTVA method
Published in Journal of alloys and compounds (15-07-2021)“…•Versatility of the LTVA (Laser-induced Thermionic Vacuum Arc) method applied for Mg:Ag alloys.•Deposition of AgMg3 thin films for OLED electrodes.•The…”
Get full text
Journal Article -
2
Strain and damage monitoring in CFRP fuselage panels using fiber Bragg grating sensors. Part II: Mechanical testing and validation
Published in Composite structures (01-01-2014)“…This is the second paper of a two-paper series describing design, implementation and validation of a strain and damage monitoring system for CFRP fuselage…”
Get full text
Journal Article -
3
Versatile techniques based on the Thermionic Vacuum Arc (TVA) and laser-induced TVA methods for Mg/Mg:X thin films deposition-A review
Published in Journal of magnesium and alloys (01-08-2024)“…•Magnesium and magnesium alloys deposited by thermionic vacuum arc.•Amorphous thin film deposition with smooth surfaces.•Laser-induced method increases the…”
Get full text
Journal Article -
4
Crystalline structure and morphology of TiO2 thin films deposited by means of hollow cathode plasma jet with supporting anode
Published in Surface & coatings technology (15-04-2016)“…TiO2 thin films with developed structure were deposited by means of a hollow cathode plasma jet (HCPJ) in a DC regime with a supporting anode. The influence of…”
Get full text
Journal Article -
5
Time-Resolved Measurements of Plasma Properties Using Electrostatic Probes in the Cross-Field Discharge of a Hall Effect Thruster
Published in Contributions to plasma physics (1988) (01-01-2013)“…Time‐resolved measurements of the plasma parameters are performed in the plume of a cross‐field discharge. The plasma potential is measured with a cylindrical…”
Get full text
Journal Article -
6
Electron Temperature Measurement in a Premixed Flat Flame Using the Double Probe Method
Published in Contributions to plasma physics (1988) (01-09-2012)“…The electron temperatures Te were measured using a double probe in a premixed methane flame produced by a calibration burner according to Hartung et al. The…”
Get full text
Journal Article -
7
Application of the Ball-Pen Probe in Two Low-Temperature Mag-netised Plasma Devices and in Torsatron TJ-K
Published in Contributions to plasma physics (1988) (01-01-2013)“…The ball‐pen probe is an innovative electric probe for direct measurements of plasma potential in magnetised hot plasma. This probe is based on the Katsumata…”
Get full text
Journal Article -
8
-
9
Experimental Study of the Discharge in the Low Pressure Plasma Jet Sputtering System
Published in Contributions to plasma physics (1988) (01-01-2013)“…This article reports on experimental study of the discharge in the low pressure plasma jet sputtering system operated in the continuous DC regime of the…”
Get full text
Journal Article -
10
The recombination of H 3+ ions with electrons: dependence on partial pressure of H 2
Published in Chemical physics letters (01-12-2000)“…We observed an increase in the effective recombination coefficient ( α eff) of the recombination of H 3 + ions with electrons with a number density of H 2, n(…”
Get full text
Journal Article -
11
Recombination of D 3 + Ions in the Afterglow of a He-Ar- D 2 Plasma
Published in Physical review letters (28-01-2002)Get full text
Journal Article -
12
Low pressure plasma-jet systems and their application for deposition of ceramic thin films
Published in Journal of Optoelectronics and Advanced Materials (01-04-2007)“…We applied the single and the double hollow cathode plasma jet systems for deposition of Ba,Sri,TiO3 (BSTO) thin films on Si and on multi-layer Si/SiO2/TiO2/Pt…”
Get full text
Journal Article -
13
2-D Experimental Study of the Plasma Parameter Variations of the Magnetically Sustained DC Discharge in Cylindrical Symmetry in Argon
Published in Contributions to plasma physics (1985) (01-11-2004)“…Two similar experimental set‐ups were used to measure axial and radial distribution of discharge plasma parameters at different magnetic fields. Both systems…”
Get full text
Journal Article Conference Proceeding -
14
Fluctuations of the magnetically-supported dc discharge in coaxial configuration
Published in Vacuum (29-11-2004)“…Floating potential fluctuations have been studied in DC discharge plasma in two cylindrical magnetron systems using the data from single and double cylindrical…”
Get full text
Journal Article -
15
Observation of wave-like structures in magnetized DC discharge in cylindrical symmetry in argon
Published in Contributions to plasma physics (1985) (2006)Get full text
Conference Proceeding -
16
Plasma diagnostics and characterization of the Mg and Mg–Zn thin films deposited by thermionic vacuum arc (TVA) method
Published in Vacuum (01-09-2019)“…The Thermionic Vacuum Arc (TVA) is an original deposition method using a combination of anodic arc and powerful electron gun system (up to 600 W) for the…”
Get full text
Journal Article -
17
Langmuir probe diagnostic for measurement of recombination rates of positive ions with electrons in stationary afterglow system
Published in Vacuum (29-11-2004)“…We attempted to compare several probe theories that described collection of charged particles by Langmuir probe at elevated pressures. We used stationary…”
Get full text
Journal Article -
18
Monte Carlo Simulations of the Electron Currents Collected by Electrostatic Probes
Published in Contributions to plasma physics (1985) (01-11-2004)“…We have carried out Monte Carlo simulation of the motion of electrons in the space charge sheath surrounding a cylindrical Langmuir (electrostatic) probe. The…”
Get full text
Journal Article Conference Proceeding -
19
Modeling and Diagnostic of the Plasma of Magnetic Field Supported Discharges
Published in Contributions to plasma physics (1988) (01-08-2005)“…In this paper we present an experimental study of the variations of plasma parameters in both the axial as well as in radial directions in a 30 cm long…”
Get full text
Journal Article -
20
Floating harmonic probe for diagnostic of pulsed discharges
Published in Surface & coatings technology (15-01-2019)“…The floating harmonic probe (FHP) is a relatively new plasma diagnostic method for electron temperature and positive ion density measurement, which can be used…”
Get full text
Journal Article