Search Results - "Kucherenko, I. S."

Refine Results
  1. 1

    Advances in nanomaterial application in enzyme-based electrochemical biosensors: a review by Kucherenko, I. S, Soldatkin, O. O, Kucherenko, D. Yu, Soldatkina, O. V, Dzyadevych, S. V

    Published in Nanoscale advances (03-12-2019)
    “…Electrochemical enzyme-based biosensors are one of the largest and commercially successful groups of biosensors. Integration of nanomaterials in the biosensors…”
    Get full text
    Journal Article
  2. 2

    A Novel Amperometric Glutamate Biosensor Based on Glutamate Oxidase Adsorbed on Silicalite by Soldatkina, O. V., Soldatkin, O. O., Kasap, B. Ozansoy, Kucherenko, D. Yu, Kucherenko, I. S., Kurc, B. Akata, Dzyadevych, S. V.

    Published in Nanoscale research letters (01-12-2017)
    “…In this work, we developed a new amperometric biosensor for glutamate detection using a typical method of glutamate oxidase (GlOx) immobilization via…”
    Get full text
    Journal Article
  3. 3

    A highly selective amperometric biosensor array for the simultaneous determination of glutamate, glucose, choline, acetylcholine, lactate and pyruvate by Kucherenko, D.Yu, Kucherenko, I.S., Soldatkin, O.O., Topolnikova, Ya.V., Dzyadevych, S.V., Soldatkin, A.P.

    “…The work was aimed at the development of a biosensor array for the simultaneous determination of six solutes (glutamate, glucose, choline, acetylcholine,…”
    Get full text
    Journal Article
  4. 4

    Potentiometric Biosensor System Based on Recombinant Urease and Creatinine Deiminase for Urea and Creatinine Determination in Blood Dialysate and Serum by Marchenko, S. V., Kucherenko, I. S., Soldatkin, O. O., Soldatkin, A. P.

    Published in Electroanalysis (New York, N.Y.) (01-07-2015)
    “…A biosensor system for simultaneous determination of creatinine and urea in blood serum and dialysate samples was developed. It consisted of creatinine and…”
    Get full text
    Journal Article
  5. 5

    Improvement of amperometric transducer selectivity using nanosized phenylenediamine films by Soldatkina, O. V., Kucherenko, I. S., Pyeshkova, V. M., Alekseev, S. A., Soldatkin, O. O., Dzyadevych, S. V.

    Published in Nanoscale research letters (14-11-2017)
    “…In this work, we studied the conditions of deposition of a semipermeable polyphenylenediamine (PPD)-based membrane on amperometric disk platinum electrodes…”
    Get full text
    Journal Article
  6. 6

    Electrochemical biosensors based on multienzyme systems: Main groups, advantages and limitations – A review by Kucherenko, I.S., Soldatkin, O.O., Dzyadevych, S.V., Soldatkin, A.P.

    Published in Analytica chimica acta (15-05-2020)
    “…In the review, the principles and main purposes of using multienzyme systems in electrochemical biosensors are analyzed. Coupling several enzymes allows an…”
    Get full text
    Journal Article
  7. 7

    CHARACTERISTICS AND OPTIMAL WORKING CONDITIONS OF AMPEROMETRIC BIOSENSOR FOR ADENOSINE TRIPHOSPHATE DETERMINATION by Kucherenko, I S, Soldatkin, O O, Didukh, D Yu, Soldatkin, A P

    Published in Biotechnologia acta (01-01-2014)
    “…Analytical characteristics of a biosensor based on glucose oxidase and hexokinase and intended for ATP determination were studied. Platinum disc electrodes…”
    Get full text
    Journal Article
  8. 8

    Application of potentiometric biosensor based on recombinant urease for urea determination in blood serum and hemodialyzate by Marchenko, S.V., Kucherenko, I.S., Hereshko, A.N., Panasiuk, I.V., Soldatkin, O.O., El'skaya, A.V., Soldatkin, A.P.

    Published in Sensors and actuators. B, Chemical (01-02-2015)
    “…Potentiometric biosensor based on two identical pH-sensitive field-effect transistors for urea determination was developed. Recombinant urease with low…”
    Get full text
    Journal Article
  9. 9

    Feasibility of application of conductometric biosensor based on acetylcholinesterase for the inhibitory analysis of toxic compounds of different nature by Stepurska, K.V., Soldatkin, О.О., Kucherenko, I.S., Arkhypova, V.M., Dzyadevych, S.V., Soldatkin, A.P.

    Published in Analytica chimica acta (07-01-2015)
    “…[Display omitted] •The conductometric biosensor based on acetylcholinesterase was characterized.•It was applied for inhibitory analysis of different toxins and…”
    Get full text
    Journal Article
  10. 10

    Novel conductometric biosensor based on three-enzyme system for selective determination of heavy metal ions by Soldatkin, O.O., Kucherenko, I.S., Pyeshkova, V.M., Kukla, A.L., Jaffrezic-Renault, N., El'skaya, A.V., Dzyadevych, S.V., Soldatkin, A.P.

    “…A differential pair of planar thin-film interdigitated electrodes, deposited on a ceramic pad, was used as a conductometric transducer. The three-enzyme system…”
    Get full text
    Journal Article
  11. 11

    A novel conductometric biosensor based on hexokinase for determination of adenosine triphosphate by Kucherenko, I.S., Kucherenko, D. Yu, Soldatkin, O.O., Lagarde, F., Dzyadevych, S.V., Soldatkin, A.P.

    Published in Talanta (Oxford) (01-04-2016)
    “…The paper presents a simple and inexpensive reusable biosensor for determination of the concentration of adenosine-5′-triphosphate (ATP) in aqueous samples…”
    Get full text
    Journal Article
  12. 12

    Determination of total creatine kinase activity in blood serum using an amperometric biosensor based on glucose oxidase and hexokinase by Kucherenko, I.S., Soldatkin, O.O., Lagarde, F., Jaffrezic-Renault, N., Dzyadevych, S.V., Soldatkin, A.P.

    Published in Talanta (Oxford) (01-11-2015)
    “…Creatine kinase (CK: adenosine-5-triphosphate–creatine phosphotransferase) is an important enzyme of muscle cells; the presence of a large amount of the enzyme…”
    Get full text
    Journal Article
  13. 13

    Development of conductometric biosensor array for simultaneous determination of maltose, lactose, sucrose and glucose by Soldatkin, O.O., Peshkova, V.M., Saiapina, O.Y., Kucherenko, I.S., Dudchenko, O.Y., Melnyk, V.G., Vasylenko, O.D., Semenycheva, L.M., Soldatkin, A.P., Dzyadevych, S.V.

    Published in Talanta (Oxford) (15-10-2013)
    “…The aim of this work was to develop an array of biosensors for simultaneous determination of four carbohydrates in solution. Several enzyme systems selective…”
    Get full text
    Journal Article
  14. 14

    Elaboration of Urease Adsorption on Silicalite for Biosensor Creation by Kucherenko, I. S., Soldatkin, O. O., Kasap, B. O., Öztürk, S., Akata, B., Soldatkin, A. P., Dzyadevych, S. V.

    Published in Electroanalysis (New York, N.Y.) (01-06-2012)
    “…A possibility of efficient urease adsorption on silicalite for the purpose of biosensor creation was investigated. The procedure of urease adsorption on…”
    Get full text
    Journal Article
  15. 15

    Development of pyruvate oxidase-based amperometric biosensor for pyruvate determination by Knyzhnykova, D. V., Topolnikova, Ya. V., Kucherenko, I. S., Soldatkin, O. O.

    Published in Biopolimery i kletka (2018)
    “…Aim. The development and optimization of the amperometric biosensor for pyruvate determina-tion. Methods. Immobilized pyruvate oxidase was used as a…”
    Get full text
    Journal Article
  16. 16

    Development of electrochemical biosensors with various types of zeolites by Soldatkina, O. V., Kucherenko, I. S., Soldatkin, O. O., Pyeshkova, V. M., Dudchenko, O. Y., Akata Kurç, B., Dzyadevych, S. V.

    Published in Applied nanoscience (01-07-2019)
    “…In the work, different types of zeolites were used for the development of enzyme-based electrochemical biosensors. Zeolites were added to the biorecognition…”
    Get full text
    Journal Article
  17. 17

    Application of Different Zeolites for Improvement of the Characteristics of a pH-FET Biosensor Based on Immobilized Urease by Soldatkin, O. O., Kucherenko, I. S., Shelyakina, M. K., Soy, E., Kirdeciler, K., Öztürk, S., Jaffrezic-Renault, N., Akata, B., Dzyadevych, S. V., Soldatkin, A. P.

    Published in Electroanalysis (New York, N.Y.) (01-02-2013)
    “…Different modifications of the zeolites Na+‐Beta and LTA were applied for improving the working characteristics of a urea biosensor. The bioselective membrane…”
    Get full text
    Journal Article
  18. 18

    APPLICATION OF GLUTAMATE-SENSITIVE BIOSENSOR FOR ANALYSIS OF FOODSTUFF by Kucherenko, D. Yu

    Published in Biotechnologia acta (01-08-2018)
    “…The aim of the work were the optimization of an amperometric glutamate-sensitive biosensor and its utilization for the determination of the glutamate…”
    Get full text
    Journal Article
  19. 19

    Application of silicalite for improvement of enzyme adsorption on the stainless steel electrodes by Pyeshkova, V. N., Dudchenko, O. Y., Soldatkin, O. O., Kucherenko, I. S., Ozansoy Kasap, B., Akata Kurc, B., Dzyadevych, S. V.

    Published in Biopolimery i kletka (2014)
    “…Aim. Improvement of analytical characteristics of an enzyme biosensor based on new inexpensive perspective stainless steel electrodes using silicalite…”
    Get full text
    Journal Article
  20. 20

    Application of enzyme/zeolite sensor for urea analysis in serum by Soldatkin, O.O., Kucherenko, I.S., Marchenko, S.V., Ozansoy Kasap, B., Akata, B., Soldatkin, A.P., Dzyadevych, S.V.

    Published in Materials Science & Engineering C (01-09-2014)
    “…Urea biosensor based on zeolite-adsorbed urease was applied for analysis of blood serum samples. It should be noted, that this biosensor has a number of…”
    Get full text
    Journal Article