Search Results - "Kucherenko, I. S."
-
1
Advances in nanomaterial application in enzyme-based electrochemical biosensors: a review
Published in Nanoscale advances (03-12-2019)“…Electrochemical enzyme-based biosensors are one of the largest and commercially successful groups of biosensors. Integration of nanomaterials in the biosensors…”
Get full text
Journal Article -
2
A Novel Amperometric Glutamate Biosensor Based on Glutamate Oxidase Adsorbed on Silicalite
Published in Nanoscale research letters (01-12-2017)“…In this work, we developed a new amperometric biosensor for glutamate detection using a typical method of glutamate oxidase (GlOx) immobilization via…”
Get full text
Journal Article -
3
A highly selective amperometric biosensor array for the simultaneous determination of glutamate, glucose, choline, acetylcholine, lactate and pyruvate
Published in Bioelectrochemistry (Amsterdam, Netherlands) (01-08-2019)“…The work was aimed at the development of a biosensor array for the simultaneous determination of six solutes (glutamate, glucose, choline, acetylcholine,…”
Get full text
Journal Article -
4
Potentiometric Biosensor System Based on Recombinant Urease and Creatinine Deiminase for Urea and Creatinine Determination in Blood Dialysate and Serum
Published in Electroanalysis (New York, N.Y.) (01-07-2015)“…A biosensor system for simultaneous determination of creatinine and urea in blood serum and dialysate samples was developed. It consisted of creatinine and…”
Get full text
Journal Article -
5
Improvement of amperometric transducer selectivity using nanosized phenylenediamine films
Published in Nanoscale research letters (14-11-2017)“…In this work, we studied the conditions of deposition of a semipermeable polyphenylenediamine (PPD)-based membrane on amperometric disk platinum electrodes…”
Get full text
Journal Article -
6
Electrochemical biosensors based on multienzyme systems: Main groups, advantages and limitations – A review
Published in Analytica chimica acta (15-05-2020)“…In the review, the principles and main purposes of using multienzyme systems in electrochemical biosensors are analyzed. Coupling several enzymes allows an…”
Get full text
Journal Article -
7
CHARACTERISTICS AND OPTIMAL WORKING CONDITIONS OF AMPEROMETRIC BIOSENSOR FOR ADENOSINE TRIPHOSPHATE DETERMINATION
Published in Biotechnologia acta (01-01-2014)“…Analytical characteristics of a biosensor based on glucose oxidase and hexokinase and intended for ATP determination were studied. Platinum disc electrodes…”
Get full text
Journal Article -
8
Application of potentiometric biosensor based on recombinant urease for urea determination in blood serum and hemodialyzate
Published in Sensors and actuators. B, Chemical (01-02-2015)“…Potentiometric biosensor based on two identical pH-sensitive field-effect transistors for urea determination was developed. Recombinant urease with low…”
Get full text
Journal Article -
9
Feasibility of application of conductometric biosensor based on acetylcholinesterase for the inhibitory analysis of toxic compounds of different nature
Published in Analytica chimica acta (07-01-2015)“…[Display omitted] •The conductometric biosensor based on acetylcholinesterase was characterized.•It was applied for inhibitory analysis of different toxins and…”
Get full text
Journal Article -
10
Novel conductometric biosensor based on three-enzyme system for selective determination of heavy metal ions
Published in Bioelectrochemistry (Amsterdam, Netherlands) (01-02-2012)“…A differential pair of planar thin-film interdigitated electrodes, deposited on a ceramic pad, was used as a conductometric transducer. The three-enzyme system…”
Get full text
Journal Article -
11
A novel conductometric biosensor based on hexokinase for determination of adenosine triphosphate
Published in Talanta (Oxford) (01-04-2016)“…The paper presents a simple and inexpensive reusable biosensor for determination of the concentration of adenosine-5′-triphosphate (ATP) in aqueous samples…”
Get full text
Journal Article -
12
Determination of total creatine kinase activity in blood serum using an amperometric biosensor based on glucose oxidase and hexokinase
Published in Talanta (Oxford) (01-11-2015)“…Creatine kinase (CK: adenosine-5-triphosphate–creatine phosphotransferase) is an important enzyme of muscle cells; the presence of a large amount of the enzyme…”
Get full text
Journal Article -
13
Development of conductometric biosensor array for simultaneous determination of maltose, lactose, sucrose and glucose
Published in Talanta (Oxford) (15-10-2013)“…The aim of this work was to develop an array of biosensors for simultaneous determination of four carbohydrates in solution. Several enzyme systems selective…”
Get full text
Journal Article -
14
Elaboration of Urease Adsorption on Silicalite for Biosensor Creation
Published in Electroanalysis (New York, N.Y.) (01-06-2012)“…A possibility of efficient urease adsorption on silicalite for the purpose of biosensor creation was investigated. The procedure of urease adsorption on…”
Get full text
Journal Article -
15
Development of pyruvate oxidase-based amperometric biosensor for pyruvate determination
Published in Biopolimery i kletka (2018)“…Aim. The development and optimization of the amperometric biosensor for pyruvate determina-tion. Methods. Immobilized pyruvate oxidase was used as a…”
Get full text
Journal Article -
16
Development of electrochemical biosensors with various types of zeolites
Published in Applied nanoscience (01-07-2019)“…In the work, different types of zeolites were used for the development of enzyme-based electrochemical biosensors. Zeolites were added to the biorecognition…”
Get full text
Journal Article -
17
Application of Different Zeolites for Improvement of the Characteristics of a pH-FET Biosensor Based on Immobilized Urease
Published in Electroanalysis (New York, N.Y.) (01-02-2013)“…Different modifications of the zeolites Na+‐Beta and LTA were applied for improving the working characteristics of a urea biosensor. The bioselective membrane…”
Get full text
Journal Article -
18
APPLICATION OF GLUTAMATE-SENSITIVE BIOSENSOR FOR ANALYSIS OF FOODSTUFF
Published in Biotechnologia acta (01-08-2018)“…The aim of the work were the optimization of an amperometric glutamate-sensitive biosensor and its utilization for the determination of the glutamate…”
Get full text
Journal Article -
19
Application of silicalite for improvement of enzyme adsorption on the stainless steel electrodes
Published in Biopolimery i kletka (2014)“…Aim. Improvement of analytical characteristics of an enzyme biosensor based on new inexpensive perspective stainless steel electrodes using silicalite…”
Get full text
Journal Article -
20
Application of enzyme/zeolite sensor for urea analysis in serum
Published in Materials Science & Engineering C (01-09-2014)“…Urea biosensor based on zeolite-adsorbed urease was applied for analysis of blood serum samples. It should be noted, that this biosensor has a number of…”
Get full text
Journal Article