Search Results - "Kricsfeld, D."
-
1
Effectiveness of transcranial and transthoracic ultrasound and microbubbles in dissolving intravascular thrombi
Published in Journal of ultrasound in medicine (01-12-2001)“…To examine the effectiveness of 1 ‐MHz and 40‐kHz ultrasound with and without microbubbles in fragmenting thrombi in attenuated conditions. First, an vitro…”
Get full text
Journal Article -
2
Effect of blood and microbubble oxygen and nitrogen content on perfluorocarbon-filled dextrose albumin microbubble size and efficacy: in vitro and in vivo studies
Published in Journal of the American Society of Echocardiography (01-05-1998)“…We hypothesized, on the basis of in vitro observations, that a higher oxygen partial pressure within perfluorocarbon-containing microbubbles (PCMB) would…”
Get more information
Journal Article -
3
Effect of transducer standoff on the detection, spatial extent, and quantification of myocardial contrast defects caused by coronary stenoses
Published in Journal of the American Society of Echocardiography (01-11-1999)“…Intermittent harmonic imaging during a continuous infusion of microbubbles may be able to quantify myocardial perfusion abnormalities. Measurements of the…”
Get more information
Journal Article -
4
Real-time perfusion imaging with low mechanical index pulse inversion Doppler imaging
Published in Journal of the American College of Cardiology (01-03-2001)“…OBJECTIVES We sought to determine how successful pulse inversion Doppler (PID) imaging would be in detecting myocardial perfusion defects during dobutamine…”
Get full text
Journal Article -
5
Real-time assessment of myocardial perfusion and wall motion during bicycle and treadmill exercise echocardiography: comparison with single photon emission computed tomography
Published in Journal of the American College of Cardiology (01-03-2001)“…OBJECTIVES We sought to determine the feasibility and accuracy of real-time imaging of myocardial contrast echocardiography (MCE) in detecting myocardial…”
Get full text
Journal Article -
6
Improved myocardial contrast with second harmonic transient ultrasound response imaging in humans using intravenous perfluorocarbon-exposed sonicated dextrose albumin
Published in Journal of the American College of Cardiology (01-05-1996)“…Objectives. The objectives of this study were to determine whether a new method of ultrasound imaging (transient response imaging) could improve the myocardial…”
Get full text
Journal Article -
7
Detection of Myocardial Perfusion in Multiple Echocardiographic Windows With One Intravenous Injection of Microbubbles Using Transient Response Second Harmonic Imaging
Published in Journal of the American College of Cardiology (15-03-1997)“…Objectives. The purpose of this study was to prove that transient response harmonic imaging could detect normal and abnormal myocardial perfusion in multiple…”
Get full text
Journal Article -
8
Noninvasive in vivo clot dissolution without a thrombolytic drug: Recanalization of thrombosed iliofemoral arteries by transcutaneous ultrasound combined with intravenous infusion of microbubbles
Published in Circulation (New York, N.Y.) (20-01-1998)“…Previous in vivo studies have shown that microbubbles not only enhance the effectiveness of thrombolytic agents in the presence of ultrasound but may also…”
Get full text
Journal Article -
9
Detection of angiographically significant coronary artery disease with accelerated intermittent imaging after intravenous administration of ultrasound contrast material
Published in The American heart journal (01-04-2000)“…Background Accelerated intermittent harmonic imaging (AII) is used to detect myocardial perfusion abnormalities after intravenous injection of ultrasound…”
Get full text
Journal Article Conference Proceeding -
10
Inhibition of carotid artery neointimal formation with intravenous microbubbles
Published in Ultrasound in medicine & biology (01-02-2001)“…Because therapeutic gene products such as synthetic antisense oligodeoxynucleotides (ODN) bind to albumin-coated microbubbles, we sought to determine whether…”
Get more information
Journal Article -
11
Myocardial cavitational activity during continuous infusion and bolus intravenous injections of perfluorocarbon-containing microbubbles
Published in Journal of the American Society of Echocardiography (01-06-2001)“…The 20-MHz component of broadband noise from inertial cavitation within the anterior myocardium of an open-chest dog was recorded during intravenous infusions…”
Get more information
Journal Article -
12
-
13
The effect of ultrasound frame rate on perfluorocarbon-exposed sonicated dextrose albumin microbubble size and concentration when insonifying at different flow rates, transducer frequencies, and acoustic outputs
Published in Journal of the American Society of Echocardiography (01-07-1997)“…The purpose of this article was to compare the effects of 1 and 30 Hz frame rates on perfluorocarbon-exposed sonicated dextrose albumin microbubble size and…”
Get more information
Journal Article -
14
Myocardial perfusion abnormalities during low-dose dobutamine after coronary reperfusion can be demonstrated with intravenous perfluorocarbon-exposed sonicated dextrose albumin ultrasound contrast
Published in The American heart journal (01-06-1996)“…We measured background-subtracted peak myocardial videointensity (PMVI) in the left anterior descending and left circumflex perfusion zones in open-chest dogs…”
Get full text
Journal Article