Search Results - "Kowalski, T. Z"

  • Showing 1 - 15 results of 15
Refine Results
  1. 1

    Performance of proportional counters filled with Xe + 5% TMA under high count rate by Kowalski, T.Z.

    “…The gas gain has been measured for a low and high count rate by means of the current method for cylindrical proportional counter of radius b = 12.5 mm with an…”
    Get full text
    Journal Article
  2. 2

    Lower size limit of the simulated biological target by TEG counter by Kowalski, T.Z.

    Published in Radiation measurements (01-08-2020)
    “…The gas gain in the range of 1.0–2 × 105 was measured for propane-based tissue equivalent gas mixtures in the pressure range of 9–500 hPa. The Zastawny and…”
    Get full text
    Journal Article
  3. 3

    Gas gain in low pressures proportional counters filled with TEG mixtures by Kowalski, T.Z.

    Published in Radiation measurements (01-01-2018)
    “…Gas gain in the range from 1 to 2 × 105 has been measured for both methane- and propane-based tissue equivalent gas mixtures in the pressure range of 9–60 hPa…”
    Get full text
    Journal Article
  4. 4

    Manifestation of aging effects in gas proportional counters by Kowalski, T.Z., Mindur, B.

    “…Studies of the behavior of cylindrical proportional tubes, 25 and 32.1 mm in diameter, under sustained irradiation were carried out with Ar/iso-pentane 95:5…”
    Get full text
    Journal Article
  5. 5

    A study of aging effects in the gas-monitoring proportional counters of the BAC calorimeter in the ZEUS experiment by Kowalski, T.Z., Mindur, B.

    “…The multi-cell proportional chambers in the backing calorimeter of the ZEUS experiment at the HERA storage ring are supplied with an Ar/CO 2 gas mixture by an…”
    Get full text
    Journal Article
  6. 6

    Performance of Xe-filled counters under high gas gain by Deptuch, M., Kowalski, T.Z., Mindur, B.

    “…Gas amplification factors, over the range 1 to ∼10 5 were measured for the mixtures of Xe/CO 2, Xe/CO 2/O 2 and Xe/CO 2/N 2 as the function of the applied…”
    Get full text
    Journal Article
  7. 7

    A Gas Scintillation Proportional Counter for the X-Ray Astronomy Satellite SAX by Smith, A., Peacock, A., Kowalski, T. Z.

    Published in IEEE transactions on nuclear science (01-02-1987)
    “…A driftless gas scintillation proportional counter is described. The instrument has several advantages over conventional GSPCs especially for applications at…”
    Get full text
    Journal Article
  8. 8
  9. 9

    Anode wire ageing in proportional detectors at the BAC calorimeter of the ZEUS experiment by Bednarek, B., Jeleń, K., Koperny, S., Kowalski, T.Z., Rulikowska-Zarȩbska, E., Zajȩac, J.

    “…Experimental results of ageing effects in proportional counters are presented. The measurements were carried out for 158 ZEUS-BAC gas system monitoring…”
    Get full text
    Journal Article
  10. 10

    Change in detector properties caused by electronegative impurities by Deptuch, M., Kowalski, T.Z., Mindur, B.

    “…Detector properties (energy resolution, gas gain, drift-time measurements) depend quite critically on the concentration of impurities. The most frequent…”
    Get full text
    Journal Article
  11. 11

    Selected problems in aging effects with gas proportional counters by Deptuch, M., Kowalski, T.Z., Mindur, B.

    “…Influence of aging on energy resolution, length of energy resolution plateau, counting characteristic and self-induced space charge effect has been measured…”
    Get full text
    Journal Article
  12. 12

    Gas gain in the straw tubes by Deptuch, M., Kowalski, T.Z., Mindur, B.

    “…Gas amplification factors, over the range 1 to 7 × 105, were measured for Ar/C02, Ar/COs/N2, Ar/C02/CF4, Ar/CO2/CF4/N2 and Ar/DME, as a function of the applied…”
    Get full text
    Journal Article
  13. 13

    Performance of straw proportional tubes under high gas gain, transition to self-quenching streamer mode and corona discharge by Deptuch, M., Kowalski, T.Z., Mindur, B.

    “…The straw operation under high gas gain in proportional mode is always accompanied by self-quenching streamer (SQS) discharges, with a probability which rises…”
    Get full text
    Journal Article
  14. 14
  15. 15

    Performance of proportional counters under high count rate, high gas gain and at high working gas pressure by Koperny, S., Kowalski, T.Z.

    “…The increase of radiation intensity measured by a proportional counter leads to the undesirable changes of its parameters, such as pulse height and energy…”
    Get full text
    Journal Article