Search Results - "Koral, K.F."
-
1
Comparison of 3-D OSEM versus 1-D SAGE for focal total-activity quantification in I-131 SPECT with HE collimation
Published in IEEE transactions on nuclear science (01-02-2005)“…A three-dimensional (3-D) ordered-subset expectation maximization (OSEM) reconstruction algorithm used fits to the average behavior of the I-131…”
Get full text
Journal Article -
2
Determining total I-131 activity within a VoI using SPECT, a UHE collimator, OSEM, and a constant conversion factor
Published in IEEE transactions on nuclear science (01-06-2004)“…Accurate determination of activity within a volume of interest is needed during radiopharmaceutical therapies. Single-photon emission computed…”
Get full text
Journal Article -
3
Quantitative I-131 SPECT reconstruction using CT side information from hybrid imaging
Published in 2009 IEEE Nuclear Science Symposium Conference Record (NSS/MIC) (01-10-2009)“…A penalized-likelihood (PL) SPECT reconstruction method using a modified regularizer that accounts for anatomical boundary side information was implemented to…”
Get full text
Conference Proceeding -
4
NATURE OF RINGING ARTIFACTS IN SPECT RECONSTRUCTION AND THEIR REDUCTION BY THE USE OF SIDE INFORMATION
Published in 2007 4th IEEE International Symposium on Biomedical Imaging: From Nano to Macro (01-04-2007)“…ML-EM iterative reconstruction algorithms tend towards ringing artifacts, and high noise, after a large number of iterations just as filtered backprojection…”
Get full text
Conference Proceeding -
5
Accurate modeling of nuclear-medicine collimators in Monte Carlo simulation of high-energy photons
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (1999)“…Monte Carlo (MC) simulation of nuclear medicine imaging is more difficult for procedures employing 131I than for those using 99mTc because of the higher…”
Get full text
Journal Article -
6
An algorithm to adjust a rigid CT-SPECT fusion so as to maximize tumor counts from CT VoI in I-131 therapies
Published in 2001 IEEE Nuclear Science Symposium Conference Record (Cat. No.01CH37310) (2001)“…The accuracy of the estimate of tumor I-131 activity in therapy patients using CT-SPECT fusion is difficult to establish. In our work, we have had the…”
Get full text
Conference Proceeding -
7
A regularized deconvolution-fitting method for Compton-scatter correction in SPECT
Published in IEEE transactions on medical imaging (1992)“…A method is presented for estimating the Compton-scatter component within the photopeak for local energy spectra measured by an Anger camera in SPECT. Assuming…”
Get full text
Journal Article -
8
An overview of imaging techniques and physical aspects of treatment planning in radioimmunotherapy
Published in Medical physics (Lancaster) (01-03-1993)“…Planar and tomographic imaging techniques and methods of treatment planning in clinical radioimmunotherapy are reviewed. In clinical trials, the data needed…”
Get more information
Journal Article -
9
Effect of including detector response in SPECT quantification of focal I-131 therapy
Published in 2001 IEEE Nuclear Science Symposium Conference Record (Cat. No.01CH37310) (01-01-2002)“…With a regularized strip-integral (1D) SAGE reconstruction, circular-orbit SPECT estimates of phantom focal 131-I activity vary with changes in the level of…”
Get full text
Conference Proceeding -
10
Correction for patient Compton scattering--current status
Published in The Journal of nuclear medicine (1978) (01-06-1991)“…Short communication…”
Get full text
Journal Article -
11
SPRINT II: a second generation single photon ring tomograph
Published in IEEE transactions on medical imaging (01-12-1988)“…SPRINT II is a stationary detector ring tomograph designed for brain imaging. Eleven two-dimensional sodium iodide camera modules that use maximum-likelihood…”
Get full text
Journal Article -
12
Changes in local energy spectra with SPECT rotation for two Anger cameras
Published in IEEE transactions on nuclear science (01-08-1995)“…We investigated the shift of local energy spectra with SPECT rotation for the GE 400 AT and the Picker Prism 3006 tomographs. A Co-57 flood source was taped to…”
Get full text
Journal Article -
13
Update on HE vs UHE collimation for focal total-activity quantification in I-131 SPECT using 3D OSEM
Published in 2003 IEEE Nuclear Science Symposium. Conference Record (IEEE Cat. No.03CH37515) (2003)“…We calibrated a scintillation camera for the counts-to-activity conversion factor, CF, by measuring a phantom consisting of a sphere containing a known 131-I…”
Get full text
Conference Proceeding -
14
Object-dependent performance comparison of two iterative reconstruction algorithms
Published in IEEE transactions on nuclear science (01-02-1988)“…Iterative algorithms are of interest for both positron-emission tomography (PET) and single-photon-emission computed tomography (SPECT) because they permit…”
Get full text
Journal Article -
15
sup 131/I tumor quantification: a new background-adaptive method
Published in 1997 IEEE Nuclear Science Symposium Conference Record (1997)“…The authors examine the accuracy of focal activity /sup 131/I quantification using either one of two new methods which don't explicitly employ…”
Get full text
Conference Proceeding -
16
Measurement of Compton scattering in phantoms by germanium detectors
Published in IEEE Transactions on Nuclear Science (Institute of Electrical and Electronics Engineers); (USA) (01-04-1990)“…Quantitative Anger-camera tomography requires correction for Compton scattering. The Anger camera spectral-fitting technique can measure scatter fractions at…”
Get full text
Conference Proceeding -
17
Recursive calculation of the two-dimensional maximum likelihood position estimate for a scintillation camera
Published in IEEE Transactions on Nuclear Science (Institute of Electrical and Electronics Engineers); (USA) (01-04-1990)“…Maximum likelihood position estimation of a scintillation event in a gamma-ray imaging detector has been described using two independent one-dimensional…”
Get full text
Journal Article Conference Proceeding -
18
A parallel Monte Carlo code for planar and SPECT imaging: implementation, verification and applications in /sup 131/I SPECT
Published in 2000 IEEE Nuclear Science Symposium. Conference Record (Cat. No.00CH37149) (2000)“…This paper reports the implementation of the SIMIND Monte Carlo code on a IBM SP2 distributed memory parallel computer. Basic aspects of running Monte Carlo…”
Get full text
Conference Proceeding -
19
Experimental evaluation of a modular scintillation camera for SPECT
Published in IEEE transactions on nuclear science (01-02-1989)“…A modular scintillation camera has been constructed for use in a ring-type single photon tomograph for nuclear medicine. Its performance has been…”
Get full text
Journal Article -
20
A Macintosh-based multi-energy data acquisition system for gamma cameras
Published in IEEE Transactions on Nuclear Science (Institute of Electrical and Electronics Engineers); (United States) (01-08-1992)“…A multi-energy data acquisition system based on the Macintosh II computer and a commercial ADC subsystem has been developed to allow the application of…”
Get full text
Journal Article Conference Proceeding