    Inappropriate subcutaneous implantable cardioverter-defibrillator shocks due to T-wave oversensing can be prevented: Implications for management by Kooiman, Kirsten M., CCDS, Knops, Reinoud E., MD, Olde Nordkamp, Louise, MD, Wilde, Arthur A.M., MD, PhD, de Groot, Joris R., MD, PhD

    Published in Heart rhythm (01-03-2014)
    “…Background Inappropriate shocks (IASs) complicate implantable cardioverter-defibrillator (ICD) therapy. The management of IASs in patients with a subcutaneous…”
    Get full text
    Journal Article
  3. 3

    Predictors and Permanency of Cardiac Conduction Disorders and Necessity of Pacing after Transcatheter Aortic Valve Implantation by BOERLAGE-VAN DIJK, KIRSTEN, KOOIMAN, KIRSTEN M., YONG, ZE YIE, WIEGERINCK, ESTHER M.A., DAMMAN, PETER, BOUMA, BERTO J., TIJSSEN, JAN G.P., PIEK, JAN J., KNOPS, REINOUD E., BAAN Jr, JAN

    Published in Pacing and clinical electrophysiology (01-11-2014)
    “…Background Transcatheter aortic valve implantation (TAVI) with the Medtronic‐CoreValve bioprosthesis (CoreValve Inc., Irvine, CA, USA) is associated with a…”
    Get full text
    Journal Article
  4. 4

    An implantable loop recorder or smartphone based single-lead electrocardiogram to detect arrhythmia in adults with congenital heart disease? by Koole, Maarten A, Kauw, Dirkjan, Kooiman, Kirsten M, de Groot, Joris R, Robbers-Visser, Danielle, Tulevski, Igor I, Mulder, Barbara J, Bouma, Berto J, Schuuring, Mark J

    Published in Frontiers in cardiovascular medicine (06-01-2023)
    “…The European Society of Cardiology (ESC) guidelines for the management of adult congenital heart disease (ACHD) recommend screening in patients at risk for…”
    Get full text
    Journal Article
  5. 5
  6. 6
  7. 7
  8. 8

    Algorithm-Based Screening May Improve Patient Selection for the Subcutaneous Implantable Defibrillator by Brouwer, Tom F., MD, Kooiman, Kirsten M., PA, Olde Nordkamp, Louise R., MD, PhD, van Halm, Vokko P., MD, PhD, Knops, Reinoud E., MD

    Published in JACC. Clinical electrophysiology (01-10-2016)
    “…Abstract Objectives The study sought to describe the concept of algorithm-based screening with an external subcutaneous implantable cardioverter-defibrillator…”
    Get full text
    Journal Article
  9. 9
  10. 10
  11. 11
  12. 12
  13. 13

    Which Patients Are Not Suitable for a Subcutaneous ICD: Incidence and Predictors of Failed QRS-T-Wave Morphology Screening by OLDE NORDKAMP, LOUISE R.A., WARNAARS, JOPPE L.F., KOOIMAN, KIRSTEN M., de GROOT, JORIS R., ROSENMÖLLER, BOUDEWIJN R.A.M., WILDE, ARTHUR A.M., KNOPS, REINOUD E.

    “…T‐Wave Analysis for the Subcutaneous ICD Background The subcutaneous cardioverter‐defibrillator (S‐ICD) relies on a pre‐implantation QRS‐T morphology screening…”
    Get full text
    Journal Article
  14. 14
  15. 15
  16. 16

    The use of a wearable cardioverter defibrillator during postmastectomy radiotherapy as an alternative for relocation of the pulse generator by Koken, Phil W., van den Bongard, Desirée H.J.G., Kooiman, Kirsten M.

    Published in Advances in radiation oncology (01-09-2023)
    “…We describe a case in which a breast cancer patient with an implantable cardioverter-defibrillator (ICD) was treated with postmastectomy followed by axillary…”
    Get full text
    Journal Article
  17. 17

    Subcutaneous Implantable Cardioverter Defibrillator Lead Failure due to Twiddler Syndrome by KOOIMAN, KIRSTEN M., BROUWER, TOM F., HALM, VOKKO P. VAN, KNOPS, REINOUD E.

    Published in Pacing and clinical electrophysiology (01-11-2015)
    “…We present a case of Twiddler syndrome in a patient with a subcutaneous implantable cardioverter defibrillator (S‐ICD). The patient presented herself to the…”
    Get full text
    Journal Article
  18. 18
  19. 19
  20. 20

    Abstract 20898: The Value of Sensing Optimization During Exercise After S-ICD Implantation by Kooiman, Kirsten M, Baalman, Sarah W, Brouwer, Tom F, Quast, Anne Floor B, Knops, Reinoud E

    Published in Circulation (New York, N.Y.) (14-11-2017)
    “…Abstract only Introduction: T-wave oversensing (TWOS) is the main cause of inappropriate shocks (IAS) in patients with a subcutaneous ICD (S-ICD). Sensing…”
    Get full text
    Journal Article