Search Results - "Klusoň, Jaroslav"

  • Showing 1 - 10 results of 10
Refine Results
  1. 1

    MODELING THE SPATIAL RESOLUTION AND FLIGHT ALTITUDE DEPENDENCE OF THE RESPONSE IN RADIOMETRIC MONITORING USING UAV by Klusoň, Jaroslav

    Published in Radiation protection dosimetry (22-08-2022)
    “…Abstract The result interpretation of a terrain airborne radiometric monitoring depends, among others, on the spatial resolution of the measurement (i.e. the…”
    Get full text
    Journal Article
  2. 2

    ESTIMATION OF RADIATION DOSES IN THE AREA OF THE MAIN PRODUCTION BLOCK OF THE NUCLEAR POWER PLANT AFTER A REACTOR ACCIDENT by Urban, Tomáš, Klusoň, Jaroslav

    Published in Radiation protection dosimetry (22-08-2022)
    “…Abstract The aim of this work is to propose methodology for estimations the characteristics of the radiation fields (and derived quantities from the field of…”
    Get full text
    Journal Article
  3. 3

    MODEL CALIBRATION OF AN AIRBORNE GAMMA SPECTROMETER FOR SEARCHING OF RADIONUCLIDE SOURCES USING UAV by Klusoň, Jaroslav, Thinová, Lenka

    Published in Radiation protection dosimetry (22-08-2022)
    “…Abstract A study of a small airborne gamma spectrometer usability, carried by unmanned aerial vehicle (UAV), during a search for radionuclide sources and…”
    Get full text
    Journal Article
  4. 4

    DOSE RATE MAPPING INSIDE THE STRAZ POD RALSKEM CALIBRATION FACILITY—MONTE CARLO APPROACH by Johnová, Kamila, Klusoň, Jaroslav

    Published in Radiation protection dosimetry (22-08-2022)
    “…Abstract The gamma spectrometry is one of the fundamental methods used in nuclear technology with well-established procedures of data acquisition and…”
    Get full text
    Journal Article
  5. 5

    THE USE OF DECONVOLUTION TECHNIQUE FOR THE ANALYSIS OF GAMMA SPECTROMETRY DATA FROM FIELD MONITORING USING UNMANNED AERIAL VEHICLES by Klusoň, Jaroslav, Thinová, Lenka

    Published in Radiation protection dosimetry (31-12-2019)
    “…Airborne gamma spectrometry is an effective tool for prompt monitoring and mapping of large areas contaminated after NPP accident, radionuclides leakage cases,…”
    Get full text
    Journal Article
  6. 6

    SIMULATION OF DOSE DISTRIBUTION IN VICINITY OF CLOUD OF CONTAMINATED AIR LEAKAGE FROM SEVERE NPP ACCIDENT by Klusoň, Jaroslav, Urban, Tomáš

    Published in Radiation protection dosimetry (31-12-2019)
    “…Method of Monte Carlo simulation of gamma radiation fields in the vicinity of the cloud of air contaminated by the radionuclides from emergency leakage from…”
    Get full text
    Journal Article
  7. 7

    Calculation of responses and analysis of experimental data for a silicon gamma spectrometer by Klusoň, Jaroslav, Jánský, Bohumil

    “…A silicon detector developed for gamma ray spectrometry (intended for measurement in the mixed neutron gamma fields, e.g. in reactor physics) was tested for…”
    Get full text
    Journal Article
  8. 8

    Air Kerma Rate estimation by means of in-situ gamma spectrometry: A Bayesian approach by Cabal, Gonzalo, Kluson, Jaroslav

    Published in Applied radiation and isotopes (01-04-2010)
    “…Bayesian inference is used to determine the Air Kerma Rate based on in-situ gamma spectrum measurement performed with an NaI(Tl) scintillation detector. The…”
    Get full text
    Journal Article
  9. 9

    Mixed Neutron and Gamma Spectra Measurements and Calculations in Pure Iron Benchmark Assembly with Cf-252 Neutron Source by Janský, Bohumil, Novák, Evžen, Turzík, Zdeněk, Kyncl, Jan, Cvachovec, František, Klusoň, Jaroslav, Trykov, Lev A., Volkov, Vitalij S., čuda, Pavel

    Published in Journal of nuclear science and technology (01-08-2002)
    “…The neutron and gamma leakage spectra measurements have been made for a benchmark spherical iron assembly with diameter of 50 cm. The Cf-252 neutron sources…”
    Get full text
    Journal Article
  10. 10

    MCNP-based computational model for the Leksell Gamma Knife by Trnka, Jiri, Novotny, Josef, Kluson, Jaroslav

    Published in Medical physics (Lancaster) (01-01-2007)
    “…We have focused on the usage of MCNP code for calculation of Gamma Knife radiation field parameters with a homogenous polystyrene phantom. We have investigated…”
    Get full text
    Journal Article