Search Results - "Kitziger, Kurt J."

  • Showing 1 - 14 results of 14
Refine Results
  1. 1

    Does Artificial Intelligence Outperform Humans Using Fluoroscopic-Assisted Computer Navigation for Total Hip Arthroplasty? by Cardenas, Justin M., Gordon, Dan, Waddell, Bradford S., Kitziger, Kurt J., Peters, Paul C., Gladnick, Brian P.

    Published in Arthroplasty today (01-06-2024)
    “…Successful total hip arthroplasty (THA) relies on the correct implant position. THA accuracy can be improved with the use of intraoperative…”
    Get full text
    Journal Article
  2. 2

    Handheld Navigation Improves Accuracy in Direct Anterior Total Hip Replacement by Kolodychuk, Nicholas L., Raszewski, Jesse A., Gladnick, Brian P., Kitziger, Kurt J., Peters, Paul C., Waddell, Bradford S.

    Published in Arthroplasty today (01-10-2022)
    “…This study sought to determine the accuracy in placing the acetabular component, estimation of leg length, offset, radiation time and dose, and operative time…”
    Get full text
    Journal Article
  3. 3

    Is Dislocation Risk due to Posterior Pelvic Tilt Reduced With Direct Anterior Approach Total Hip Arthroplasty? by Fritz, Justin K., Waddell, Bradford S., Kitziger, Kurt J., Peters, Paul C., Gladnick, Brian P.

    Published in The Journal of arthroplasty (01-11-2021)
    “…Pelvic tilt affects acetabular anteversion, and thus total hip arthroplasty (THA) dislocation risk. The pubic symphysis-sacrococcygeal distance (PSCD) is an…”
    Get full text
    Journal Article
  4. 4

    Mitigating calcar fracture risk with automated impaction during total hip arthroplasty by Gordon, Dan, Cardenas, Justin M., Fawley, David, Kitziger, Kurt J., Gladnick, Brian P.

    Published in Journal of orthopaedics (01-01-2025)
    “…Automated broaching has recently been introduced for total hip arthroplasty (THA), with the goal of improving surgical efficiency and reducing surgeon…”
    Get full text
    Journal Article
  5. 5

    Fluoroscopy-Assisted Computer Navigation Accurately Determines Cup Position and Leg Length for Anterior Hip Arthroplasty by Kitziger, Raymond L, Dugan, Annie L, Waddell, Bradford S, Kitziger, Kurt J, Peters, Jr, Paul C, Gladnick, Brian P

    Published in Orthopedics (Thorofare, N.J.) (01-07-2024)
    “…Recently, fluoroscopy-assisted computer navigation has been developed to assess intraoperative cup inclination/anteversion and leg-length discrepancy (LLD) in…”
    Get full text
    Journal Article
  6. 6

    Triaging Total Hip Arthroplasty During the COVID-19 Pandemic by Rizkalla, James M., Gladnick, Brian P., Bhimani, Aamir A., Wood, Dorian S., Kitziger, Kurt J., Peters, Paul C.

    “…Purpose of Review The purpose of this review was to evaluate the available literature to determine what may be considered urgent indications for total hip…”
    Get full text
    Journal Article
  7. 7

    Surgical automation reduces operating time while maintaining accuracy for direct anterior total hip arthroplasty by Bhimani, Aamir A., Rizkalla, James M., Kitziger, Kurt J., Peters, Paul C., Schubert, Richard D., Gladnick, Brian P.

    Published in Journal of orthopaedics (01-11-2020)
    “…Investigate the efficiency/accuracy of surgical automation versus manual component implantation in DA THA. Retrospective review of 111 hips: 51 hips via…”
    Get full text
    Journal Article
  8. 8

    Financial impact of removal of total knee arthroplasty from the inpatient-only list for a physician-owned BPCI program by Rizkalla, James M., Bhimani, Aamir A., Kitziger, Kurt J., Peters, Paul C., Schubert, Richard D., Gladnick, Brian P.

    Published in Journal of orthopaedics (01-07-2020)
    “…Assessing financial effects of removal of TKA from CMS inpatient-only list on physician-owned bundles. We determined whether Medicare TKAs remained inpatient,…”
    Get full text
    Journal Article
  9. 9

    Accelerometer-based navigation improves early patient-reported outcomes after gap-balanced total knee arthroplasty by Wood, Dorian S., Eckel, Tara M., Kitziger, Kurt J., Peters, Paul C., Gladnick, Brian P.

    Published in Journal of orthopaedics (01-01-2021)
    “…To investigate the effect of accelerometry-based navigation (ABN) on early clinical outcomes after TKA. 71 TKAs were performed via ABN and 37 TKAs via standard…”
    Get full text
    Journal Article
  10. 10

    Decreased costs with maintained patient satisfaction after total joint arthroplasty in a physician-owned hospital by Wood, Dorian S., Watson, Shawna L., Eckel, Tara M., Peters, Paul C., Kitziger, Kurt J., Gladnick, Brian P.

    Published in Journal of orthopaedics (01-03-2021)
    “…Comparing total joint arthroplasty (TJA) costs and patient-reported outcomes between a physician-owned hospital (POH) and a non-POH. Costs for each 90-day TJA…”
    Get full text
    Journal Article
  11. 11

    Deep Venous Thrombosis after Total Joint Arthroplasty. The Role of Compression Ultrasonography and the Importance of the Experience of the Technician by GARINO, JONATHAN P, LOTKE, PAUL A, KITZIGER, KURT J, STEINBERG, MARVIN E

    “…We evaluated the influence of the expertise of the technician on the accuracy of compression ultrasonography as a screening test to detect postoperative deep…”
    Get full text
    Journal Article
  12. 12

    Component design affecting patellofemoral complications after total knee arthroplasty by Theiss, S M, Kitziger, K J, Lotke, P S, Lotke, P A

    Published in Clinical orthopaedics and related research (01-05-1996)
    “…Three hundred one primary cemented total knee arthroplasties were performed in 289 patients. Two different prostheses were used; 148 knees received the…”
    Get more information
    Journal Article
  13. 13

    Acute pulmonary edema associated with use of low-molecular weight dextran for prevention of microvascular thrombosis by Kitziger, K J, Sanders, W E, Andrews, C P

    Published in The Journal of hand surgery (American ed.) (01-11-1990)
    “…Low-molecular weight dextran is commonly used to prevent thrombosis after microvascular procedures; however, the potential complications of this drug are not…”
    Get more information
    Journal Article
  14. 14

    Failed partial meniscectomy by Kitziger, K J, DeLee, J C

    Published in Clinics in sports medicine (01-07-1990)
    “…Both patients and doctors have come to expect a high rate of success from arthroscopic partial meniscectomy. Failure of this procedure may result from a number…”
    Get more information
    Journal Article