Search Results - "Khilchenko, A."

Refine Results
  1. 1

    Broadband Signal Amplification Paths for Semiconductor Radiation and Particle Detectors (Review) by Puryga, E. A., Khilchenko, A. D., Kvashnin, A. N., Moiseev, D. V., Ivanenko, S. V.

    “…This study is devoted to the development of amplifying paths for plasma diagnostics, a significant part of which use semiconductor detectors as sensors that…”
    Get full text
    Journal Article
  2. 2
  3. 3

    Data Acquisition System for Thomson Scattering Diagnostics on GDT by Puryga, E. A., Lizunov, A. A., Ivanenko, S. V., Khilchenko, A. D., Kvashnin, A. N., Zubarev, P. V., Moiseev, D. V.

    Published in IEEE transactions on plasma science (01-06-2019)
    “…This paper describes a data acquisition system for Thomson scattering diagnostics on a gas-dynamic trap (GDT) (the Budker Institute of Nuclear Physics,…”
    Get full text
    Journal Article
  4. 4

    The Measuring System for the Thomson Scattering Diagnostics of the GOL-3 and GDT Facilities by Puryga, E. A., Khilchenko, A. D., Kvashnin, A. N., Zubarev, P. V., Prikhodko, V. V., Ivanenko, S. V., Moiseev, D. V., Kasatov, A. A., Maksimov, V. V., Vyacheslavov, L. N.

    “…The measuring system for Thomson scattering diagnostics of the GOL-3 and GDT facilities at the Budker Institute of Nuclear Physics is described. The system has…”
    Get full text
    Journal Article
  5. 5

    Multi-purpose fast neutron spectrum analyzer with real-time signal processing by Sulyaev, Yu.S., Puryga, E.A., Khilchenko, A.D., Kvashnin, A.N., Polosatkin, S.V., Rovenskikh, A.F., Burdakov, A.V., Grishnyaev, E.V.

    “…Diagnostics of hot ion component of plasma on the products of fusion reactions is widely used on thermonuclear facilities. In case of employment of neutron…”
    Get full text
    Journal Article
  6. 6

    Pulse-signal digitizer for high-temperature plasma diagnostic systems by Ivanova, A. A., Zubarev, P. V., Ivanenko, S. V., Kvashnin, A. N., Kotelnikov, A. I., Moiseev, D. V., Puryga, E. A., Khilchenko, A. D., Khilchenko, V. A., Shvyrev, V. G.

    “…A pulse-signal digitizer for laser, neutron, and gamma diagnostics of high-temperature plasma at the GOL-3 and GDL (Budker Institute of Nuclear Physics…”
    Get full text
    Journal Article
  7. 7

    Optimised plasma stabilisation at TEXTOR with an advanced, real-time digital control scheme by Mitri, M., Nicolai, D., Neubauer, O., Lambertz, H.T., Schmidt, I., Khilchenko, A., Schweer, B., Maier, U., Samm, U.

    Published in Fusion engineering and design (01-06-2009)
    “…The tokamak TEXTOR at the Research Centre in Jülich is in operation since more than 25 years. The various control systems at the start, in 1982, were based on…”
    Get full text
    Journal Article
  8. 8

    Oxidation and uptake of LDL by monocyte-derived macrophages from blood of patients with IHD by Bilenko, M. V., Khilchenko, A. V., Nikitina, N. A., Aksenov, D. V.

    “…The main goal of this study was to test our hypothesis that monocyte-derived macrophages of patients with ischemic heart disease (IHD, MP IHD ) are in vivo…”
    Get full text
    Journal Article
  9. 9

    Dispersion interferometry diagnostic at Globus-M2 by Ivanenko, S.V., Solomakhin, A.l., Zubarev, P.V., Kvashnin, A.N., Kovalenko, Yu.V., Puryga, E.A., Solokha, V.V., Kurskiev, G.S., Zhiltsov, N.S., Shulyatiev, K.D., Khilchenko, A.D., Minaev, V.B., Bagryansky, P.A.

    Published in Fusion engineering and design (01-05-2024)
    “…•The dispersion interferometer based on CO2 laser was developed for Globus-M2 tokamak.•Time resolution = 20 μs, spatial resolution = 0.02 m, measurement…”
    Get full text
    Journal Article
  10. 10

    Prototype of Data Acquisition Systems for ITER Divertor Thomson Scattering Diagnostic by Ivanenko, S. V., Khilchenko, A. D., Puryga, E. A., Ovchar, V. K., Zubarev, P. V., Kvashnin, A. N., Ivanova, A. A., Kotelnikov, A. I.

    Published in IEEE transactions on nuclear science (01-06-2015)
    “…The prototype of uniquely designed complex data acquisition system for ITER divertor Thomson scattering diagnostic was developed. It allows recording short…”
    Get full text
    Journal Article
  11. 11

    Fast neutron flux analyzer with real-time digital pulse shape discrimination by Ivanova, A.A., Zubarev, P.V., Ivanenko, S.V., Khilchenko, A.D., Kotelnikov, A.I., Polosatkin, S.V., Puryga, E.A., Shvyrev, V.G., Sulyaev, Yu.S.

    “…Investigation of subthermonuclear plasma confinement and heating in magnetic fusion devices such as GOL–3 and GDT at the Budker Institute (Novosibirsk, Russia)…”
    Get full text
    Journal Article
  12. 12

    Data recording system of a dispersion interferometer based on a CO2 laser by Khil’chenko, A. D., Kvashnin, A. N., Ivanenko, S. V., Zubarev, P. V., Moiseev, D. V., Kovalenko, Yu. V.

    “…The data recording system of a multichannel double-pass dispersion interferometer based on a CO 2 laser is described. This system has been designed to record…”
    Get full text
    Journal Article
  13. 13

    An ADC12500 multifunction fast recorder by Puryga, E. A., Khilchenko, A. D., Kvashnin, A. N., Zubarev, P. V., Ivanova, A. A., Ivanenko, S. V.

    “…A wideband two-channel waveform recorder module based on 12-bit analog-to-digital converters with a maximal sampling frequency of 500 MHz is described. The…”
    Get full text
    Journal Article
  14. 14

    Thomson scattering diagnostic data acquisition systems for modern fusion systems by Ivanenko, S. V., Khilchenko, A. D., Ovchar, V. K., Zubarev, P. V., Kvashnin, A. N., Puryga, E. A., Ivanova, A. A., Kotelnikov, A. I.

    “…Uniquely designed complex data acquisition system for Thomson scattering diagnostic was developed. It allows recording short duration (3-5 ns) scattered pulses…”
    Get full text
    Conference Proceeding
  15. 15

    Data acquisition system prototype for Thomson scattering diagnostic of ITER divertor by Ivanenko, S., Zubarev, P., Kvashnin, A., Puryga, E., Ivanova, A., Khilchenko, A.

    “…We present a prototype of the data acquisition system for Thomson scattering diagnostic of ITER divertor. The system allows the recording of the plasma…”
    Get full text
    Conference Proceeding
  16. 16

    An adaptive γ-ray spectrometer with a high event processing rate by Ivanova, A. A., Aleinik, V. I., Ivanenko, S. V., Kvashnin, A. N., Puryga, E. A., Rovenskikh, A. F., Sulyaev, Yu. S., Khilchenko, A. D.

    “…A fast γ-ray spectrometer adaptable to the scintillator type is described. This spectrometer is capable of processing a γ-ray energy spectrum (with a…”
    Get full text
    Journal Article
  17. 17

    Optical tomography diagnostic for study of neutral plasma component in the gas dynamic trap by Lizunov, A, Khilchenko, A, Moiseev, D, Zubarev, P

    Published 22-02-2021
    “…The optical diagnostic observing D-alpha line emission along multiple chords in the boundary region close to the plasma absorber, is recently installed at the…”
    Get full text
    Journal Article
  18. 18

    Multifunction fast recorder ADC12500 for plasma diagnostics by Puryga, E. A., Ivanenko, S. V., Kvashnin, A. N., Ivanova, A. A., Zubarev, P. V., Khilchenko, A. D.

    “…The ADC12500 recorder is oriented for designing of multichannel synchronous measuring systems and data preprocessing in the real-time mode. It includes two…”
    Get full text
    Conference Proceeding
  19. 19

    Gamma-ray spectrometer with high event processing rate by Ivanova, A. A., Ivanenko, S. V., Kvashnin, A. N., Puriga, E. A., Rovenskikh, A. F., Khilchenko, A. D.

    “…This research contributes to the development of γ- and n- diagnostics for systems with magnetic plasma confinement: ITER and linear traps like GOL-3 and GDT at…”
    Get full text
    Conference Proceeding
  20. 20

    Thomson scattering diagnostic at the gas dynamic trap by Lizunov, A, Berbasova, T, Khilchenko, A, Kvashnin, A, Puryga, E, Sandomirsky, A, Zubarev, P

    Published 29-08-2022
    “…The incoherent Thomson scattering diagnostic with multiple line of sight is installed at the gas dynamic trap (GDT) for measurements of radial profiles of the…”
    Get full text
    Journal Article