Search Results - "Khil’chenko, A. D."
-
1
Broadband Signal Amplification Paths for Semiconductor Radiation and Particle Detectors (Review)
Published in Instruments and experimental techniques (New York) (01-02-2022)“…This study is devoted to the development of amplifying paths for plasma diagnostics, a significant part of which use semiconductor detectors as sensors that…”
Get full text
Journal Article -
2
Data recording system of a dispersion interferometer based on a CO2 laser
Published in Instruments and experimental techniques (New York) (01-05-2009)“…The data recording system of a multichannel double-pass dispersion interferometer based on a CO 2 laser is described. This system has been designed to record…”
Get full text
Journal Article -
3
Erratum to: Broadband Signal Amplification Paths for Semiconductor Radiation and Particle Detectors (Review)
Published in Instruments and experimental techniques (New York) (2022)“…An Erratum to this paper has been published: https://doi.org/10.1134/S0020441222030204…”
Get full text
Journal Article -
4
Data Acquisition System for Thomson Scattering Diagnostics on GDT
Published in IEEE transactions on plasma science (01-06-2019)“…This paper describes a data acquisition system for Thomson scattering diagnostics on a gas-dynamic trap (GDT) (the Budker Institute of Nuclear Physics,…”
Get full text
Journal Article -
5
The Measuring System for the Thomson Scattering Diagnostics of the GOL-3 and GDT Facilities
Published in Instruments and experimental techniques (New York) (01-11-2018)“…The measuring system for Thomson scattering diagnostics of the GOL-3 and GDT facilities at the Budker Institute of Nuclear Physics is described. The system has…”
Get full text
Journal Article -
6
A Dispersion Interferometer Based on a CO2 Laser
Published in Instruments and experimental techniques (New York) (01-09-2005)Get full text
Journal Article -
7
Multi-purpose fast neutron spectrum analyzer with real-time signal processing
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (21-08-2013)“…Diagnostics of hot ion component of plasma on the products of fusion reactions is widely used on thermonuclear facilities. In case of employment of neutron…”
Get full text
Journal Article -
8
The Data-Acquisition System of the GOL-3 Facility
Published in Instruments and experimental techniques (New York) (01-03-2004)Get full text
Journal Article -
9
Dispersion interferometry diagnostic at Globus-M2
Published in Fusion engineering and design (01-05-2024)“…•The dispersion interferometer based on CO2 laser was developed for Globus-M2 tokamak.•Time resolution = 20 μs, spatial resolution = 0.02 m, measurement…”
Get full text
Journal Article -
10
Prototype of Data Acquisition Systems for ITER Divertor Thomson Scattering Diagnostic
Published in IEEE transactions on nuclear science (01-06-2015)“…The prototype of uniquely designed complex data acquisition system for ITER divertor Thomson scattering diagnostic was developed. It allows recording short…”
Get full text
Journal Article -
11
Fast neutron flux analyzer with real-time digital pulse shape discrimination
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (11-08-2016)“…Investigation of subthermonuclear plasma confinement and heating in magnetic fusion devices such as GOL–3 and GDT at the Budker Institute (Novosibirsk, Russia)…”
Get full text
Journal Article -
12
Pulse-signal digitizer for high-temperature plasma diagnostic systems
Published in Instruments and experimental techniques (New York) (01-05-2016)“…A pulse-signal digitizer for laser, neutron, and gamma diagnostics of high-temperature plasma at the GOL-3 and GDL (Budker Institute of Nuclear Physics…”
Get full text
Journal Article -
13
Thomson scattering diagnostic data acquisition systems for modern fusion systems
Published in 2015 4th International Conference on Advancements in Nuclear Instrumentation Measurement Methods and their Applications (ANIMMA) (01-04-2015)“…Uniquely designed complex data acquisition system for Thomson scattering diagnostic was developed. It allows recording short duration (3-5 ns) scattered pulses…”
Get full text
Conference Proceeding -
14
An ADC12500 multifunction fast recorder
Published in Instruments and experimental techniques (New York) (01-05-2012)“…A wideband two-channel waveform recorder module based on 12-bit analog-to-digital converters with a maximal sampling frequency of 500 MHz is described. The…”
Get full text
Journal Article -
15
An adaptive γ-ray spectrometer with a high event processing rate
Published in Instruments and experimental techniques (New York) (2012)“…A fast γ-ray spectrometer adaptable to the scintillator type is described. This spectrometer is capable of processing a γ-ray energy spectrum (with a…”
Get full text
Journal Article -
16
Multifunction fast recorder ADC12500 for plasma diagnostics
Published in 2012 IEEE Nuclear Science Symposium and Medical Imaging Conference Record (NSS/MIC) (01-10-2012)“…The ADC12500 recorder is oriented for designing of multichannel synchronous measuring systems and data preprocessing in the real-time mode. It includes two…”
Get full text
Conference Proceeding -
17
Gamma-ray spectrometer with high event processing rate
Published in 2012 IEEE Nuclear Science Symposium and Medical Imaging Conference Record (NSS/MIC) (01-10-2012)“…This research contributes to the development of γ- and n- diagnostics for systems with magnetic plasma confinement: ITER and linear traps like GOL-3 and GDT at…”
Get full text
Conference Proceeding -
18
New optical diagnostics of the VEPP-4M collider
Published in Physics of particles and nuclei letters (01-12-2008)“…The experiments in measuring the dynamic aperture and beam energy spread of the VEPP-4M collider [1] are described. The optical diagnostics of the accelerator…”
Get full text
Journal Article -
19
The update of the recording system for the Thomson scattering diagnostic complex on GDT
Published in 2018 IEEE Nuclear Science Symposium and Medical Imaging Conference Proceedings (NSS/MIC) (01-11-2018)“…This paper describes the data acquisition system for the Thomson scattering diagnostic on GDT (Gas Dynamic Trap) located in the Budker Institute of Nuclear…”
Get full text
Conference Proceeding -
20
Thomson scattering diagnostic data acquisition systems for modern fusion systems
Published in 2015 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) (01-10-2015)“…Uniquely designed complex data acquisition system for Thomson scattering diagnostic was developed. It allows recording short duration (3-5 ns) scattered pulses…”
Get full text
Conference Proceeding