Challenges Associated with Effective Implementation of CT Dose Check Standards and Radiation Monitoring Index in Computed Tomography: Healthcare Sector Experience

Computed tomography (CT) radiation dose management tools should be used whenever possible, particularly with the increasing demand for acquiring CT studies. Herein, we aim to assess the advantages and challenges faced with implementing two CT dose management tools. A second aim was to highlight CT e...

Full description

Saved in:
Bibliographic Details
Published in:Healthcare (Basel) Vol. 10; no. 10; p. 1970
Main Authors: Dalah, Entesar Zawam, Al Musfari, Yousuf Mohammad, Ali, Badriya Mohd Hassan, Al Hammadi, Anwaar Abdulrahim, Beevi, Hashim Abdul Azeez, Jaber, Manal Ibrahim, Al-Ali, Alyazya Akeel, Alkharoossi, Ayesha Khalid, Hashemi, Fairooz Hussain Al, Alkhatib, Fatma Mahmood, Khan, Sabaa Anam Aqil
Format: Journal Article
Language:English
Published: Basel MDPI AG 01-10-2022
MDPI
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Computed tomography (CT) radiation dose management tools should be used whenever possible, particularly with the increasing demand for acquiring CT studies. Herein, we aim to assess the advantages and challenges faced with implementing two CT dose management tools. A second aim was to highlight CT examinations exceeding dose notification values (NVs) and define the common set of causes. A total of 13,037 CT examinations collected over a six-month period, were evaluated, using two independent CT dose management tools, a CT Dose Notification prospective-view tool (PVT) following CT Dose Check standards and a retrospective statistical-based view tool (RSVT). Dose NVs were set to twice the Local Diagnostic Reference Levels. There was a significant discrepancy between dose NV counts registered with prospective (4.15%) and retrospective (7.98%) tools using T-Test. A core difference is the dose configuration setup, with PVT and RSVT being dose per series and whole study, respectively. Both prospective and retrospective dose management tools were equally useful despite their technical difference. Configuring the CT prospective dose notification check tool using NVs that is based on DRLs has limitations, and one needs to establish dose NVs per series to overcome this technical hurdle. Technical challenges make the implementation of CT Dose Check standards puzzling.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:2227-9032
2227-9032
DOI:10.3390/healthcare10101970