Search Results - "Keppler, P."
-
1
Treatment of rotational malalignment of the lower leg
Published in Der Unfallchirurg (01-03-2018)“…Rotational malalignment after intramedullary nailing of tibial shaft fractures is not uncommon. In-toeing and out-toeing conditions in children are often the…”
Get full text
Journal Article -
2
Behandlung von Torsionsabweichungen am Unterschenkel
Published in Der Unfallchirurg (01-03-2018)“…Zusammenfassung Hintergrund Posttraumatische Torsionsabweichungen im Bereich der Unterschenkel treten v. a. nach Marknagelosteosynthesen auf. Bei Kindern sind…”
Get full text
Journal Article -
3
Noninvasive ultrasonic measuring system for bone geometry examination
Published in The international journal of medical robotics + computer assisted surgery (01-03-2011)“…Background Bone deformities are typically identified through standard radiograms. Since X‐ray examinations are easily applied and offer high quality imaging,…”
Get full text
Journal Article -
4
Locked posterior dislocation of the shoulder: treatment using rotational osteotomy of the humerus
Published in Journal of orthopaedic trauma (01-08-1994)“…This study reports the use of rotational osteotomy in 10 patients with locked posterior dislocation of the shoulder. The average interval between injury and…”
Get more information
Journal Article -
5
Clinical accuracy of fluoroscopic navigation at the thoracic and lumbar spine
Published in Zeitschrift für Orthopädie und Unfallchirurgie (01-07-2008)“…The aim of the present study was the verification of the accuracy of 2-D fluoroscopy-based navigated pedicle screws at the thoracic and lumbar spine in a case…”
Get more information
Journal Article -
6
Clinical accuracy of fluoroscopic navigation at the thoracic and lumbar spine
Published in Zentralblatt für Chirurgie (01-12-2008)“…The aim of the present study was the verification of the accuracy of 2D fluoroscopy-based navigated pedicle screw placements at the thoracic and lumbar spine…”
Get more information
Journal Article -
7
Summary of experimental studies, at CERN, on a positron source using crystal effects
Published in Nuclear instruments & methods in physics research. Section B, Beam interactions with materials and atoms (01-11-2005)“…A new kind of positron sources for future linear colliders, where the converter is an aligned tungsten crystal, oriented on the 〈111〉-axis, has been studied at…”
Get full text
Journal Article -
8
Magnetic field distribution and characteristic fields of the vortex lattice for a clean superconducting niobium sample in an external field applied along a three-fold axis
Published in Physical review. B, Condensed matter and materials physics (08-05-2014)“…The field distribution in the vortex lattice of a pure niobium single crystal with an external field applied along a three-fold axis has been investigated by…”
Get full text
Journal Article -
9
Channeling of high-energy particles in bent crystals – Experiments at the CERN SPS
Published in Nuclear instruments & methods in physics research. Section B, Beam interactions with materials and atoms (01-04-2000)“…During the latest decade, experiments have been performed at the CERN SPS to investigate the use of high-energy channeled nuclei in bent crystals for…”
Get full text
Journal Article -
10
Evidence for Cooper pair diffraction on the vortex lattice of superconducting niobium
Published in Physical review. B, Condensed matter and materials physics (29-10-2013)“…We investigated the Abrikosov vortex lattice (VL) of a pure niobium single crystal with the muon spin rotation ( mu SR) technique. Analysis of the mu SR data…”
Get full text
Journal Article -
11
Experimental study of a crystal positron source
Published in Physics letters. B (17-01-2002)“…Tungsten crystals oriented on their 〈111〉 axis, were submitted to 6 and 10 GeV electron beams on the SPS-CERN transfer lines. The crystals, 4 and 8 mm thick,…”
Get full text
Journal Article -
12
Deflection and Extraction of Pb Ions up to 33 TeV / c by a Bent Silicon Crystal
Published in Physical review letters (01-11-1997)Get full text
Journal Article -
13
Experiment with a crystal-assisted positron source using 6 and 10 GeV electrons
Published in Nuclear instruments & methods in physics research. Section B, Beam interactions with materials and atoms (2003)“…Axially oriented crystals, penetrated by high-energy electrons, are powerful photon sources and, hence, intense positron sources. Such kinds of positron…”
Get full text
Journal Article -
14
Diagnostik der posttraumatischen Beindeformitäten
Published in Trauma und Berufskrankheit (01-12-2006)Get full text
Journal Article -
15
Non-union of pediatric lateral humeral condyle following post-traumatic cubitus valgus
Published in Der Unfallchirurg (01-04-2011)“…Non-union of the pediatric lateral humeral condyle following post-traumatic cubitus valgus is a severe complication after inadequate treatment. We report on a…”
Get full text
Journal Article -
16
Computer assisted treatment of pelvis fractures
Published in Studies in health technology and informatics (2001)“…The presented approach is the realization of a minimal invasive treatment of pelvis fractures using the computer aided surgery (CAS). Main problem of tracking…”
Get more information
Journal Article -
17
Electron focusing in Ag and W single crystals
Published in Physical review. B, Condensed matter (15-07-1996)Get full text
Journal Article -
18
Computer simulation of osteotomy correction
Published in Studies in health technology and informatics (2001)“…This paper describes a novel approach to correct osteotomy deformities of long bones using virtual reality and image processing techniques on personal…”
Get more information
Journal Article -
19
Deflection of 32.8 TeV/c fully stripped Pb ions by means of a bent Si crystal
Published in Nuclear instruments & methods in physics research. Section B, Beam interactions with materials and atoms (01-04-2000)“…New results on the deflection of fully stripped 32.8 TeV/c Pb ions in a bent Si crystal at the CERN-SPS are reported. Deflection efficiencies above 10% have…”
Get full text
Journal Article -
20
From planning of complex bone deformities correction to computer aided operation
Published in Proceedings 14th IEEE Symposium on Computer-Based Medical Systems. CBMS 2001 (2001)“…The aim of this project is to develop a new approach for the correction of bone deformities using a computer-aided surgery tool. We use measurement-based…”
Get full text
Conference Proceeding