Search Results - "Kaniusas, E."

Refine Results
  1. 1

    Automatic multimodal detection for long-term seizure documentation in epilepsy by Fürbass, F, Kampusch, S, Kaniusas, E, Koren, J, Pirker, S, Hopfengärtner, R, Stefan, H, Kluge, T, Baumgartner, C

    Published in Clinical neurophysiology (01-08-2017)
    “…Highlights • Automatic seizure detection assessing efficacy of EEG/ECG/EMG signals for seizure documentation. • Multi-center evaluation including 92 patients…”
    Get full text
    Journal Article
  2. 2

    Pupillary response to percutaneous auricular vagus nerve stimulation in alcohol withdrawal syndrome: A pilot trial by Treiber, M.C., Grünberger, J., Vyssoki, B., Szeles, J.C., Kaniusas, E., Kampusch, S., Stöhr, H., Walter, H., Lesch, O.M., König, D., Kraus, C.

    Published in Alcohol (Fayetteville, N.Y.) (01-02-2024)
    “…Autonomic symptoms in alcohol withdrawal syndrome (AWS) are associated with a sympathetic-driven imbalance of the autonomic nervous system. To restore…”
    Get full text
    Journal Article
  3. 3

    Influence of reconstruction settings in electrical impedance tomography on figures of merit and physiological parameters by Thürk, F, Elenkov, M, Waldmann, A D, Böhme, S, Braun, C, Adler, A, Kaniusas, E

    Published in Physiological measurement (30-09-2019)
    “…Electrical impedance tomography (EIT) is a non-invasive and relatively cheap imaging technique allowing continuous monitoring of lung function at the bedside…”
    Get more information
    Journal Article
  4. 4

    Detection of thoracic vascular structures by electrical impedance tomography: a systematic assessment of prominence peak analysis of impedance changes by Wodack, K H, Buehler, S, Nishimoto, S A, Graessler, M F, Behem, C R, Waldmann, A D, Mueller, B, Böhm, S H, Kaniusas, E, Thürk, F, Maerz, A, Trepte, C J C, Reuter, D A

    Published in Physiological measurement (28-02-2018)
    “…Electrical impedance tomography (EIT) is a non-invasive and radiation-free bedside monitoring technology, primarily used to monitor lung function. First…”
    Get more information
    Journal Article
  5. 5

    Acoustical signal properties for cardiac/respiratory activity and apneas by Kaniusas, E., Pfutzner, H., Saletu, B.

    “…Traditionally, auscultation is applied to the diagnosis of either respiratory disturbances by respiratory sounds or cardiac disturbances by cardiac sounds. In…”
    Get full text
    Journal Article
  6. 6

    Contactless flow detection with magnetostrictive bilayers by Traxler, S., Kosel, J., Pfützner, H., Kaniusas, E., Mehnen, L., Giouroudi, I.

    Published in Sensors and actuators. A. Physical. (10-04-2008)
    “…The paper concerns the contactless detection of an airflow through a tube by the use of a magnetostrictive bilayer strip as a sensor element. A bilayer mounted…”
    Get full text
    Journal Article
  7. 7

    Method for continuous nondisturbing monitoring of blood pressure by magnetoelastic skin curvature sensor and ECG by Kaniusas, E., Pfutzner, H., Mehnen, L., Kosel, J., Tellez-Blanco, C., Varoneckas, G., Alonderis, A., Meydan, T., Vazquez, M., Rohn, M., Merlo, A.M., Marquardt, B.

    Published in IEEE sensors journal (01-06-2006)
    “…This paper concerns continuous nondisturbing estimation of blood pressure using mechanical plethysmography in connection with standard electrocardiography…”
    Get full text
    Journal Article
  8. 8

    Magnetostrictive bilayers for multi-functional sensor families by Pfützner, H., Kaniusas, E., Kosel, J., Mehnen, L., Meydan, T., Vázquez, M., Rohn, M., Merlo, A.M., Marquardt, B.

    Published in Sensors and actuators. A. Physical. (24-05-2006)
    “…The present paper summarizes the development of new types of soft magnetic materials which are highly sensitive to bending or temperature, respectively. They…”
    Get full text
    Journal Article
  9. 9

    Cardiovascular Oscillations of the Carotid Artery Assessed by Magnetoelastic Skin Curvature Sensor by Kaniusas, Eugenijus, Pfutzner, Helmut, Mehnen, Lars, Kosel, JÜrgen, Varoneckas, Giedrius, Alonderis, Audrius, Zakarevicius, Linas

    “…The present study concerns the nondisturbing assessment of cardiovascular oscillations of the carotid artery using a novel skin curvature sensor on the neck…”
    Get full text
    Journal Article
  10. 10

    Magnetostrictive amorphous bimetal sensors by Mehnen, L., Pfützner, H., Kaniusas, E.

    “…The paper describes the application of a magnetostrictive amorphous ribbon (AR) for the detection of bending. In order to increase sensitivity, a bimetal…”
    Get full text
    Journal Article
  11. 11

    First magnetic materials with sensitivity for the physical quantity “curvature” by Pfützner, H., Kaniusas, E., Kosel, J., Mehnen, L., Meydan, T., Borza, F., Vázquez, M., Rohn, M., Merlo, A.M., Marquardt, B.

    “…All magnetostrictive types of soft magnetic materials show some weak sensitivity to processes of bending. However, as demonstrated here, a prerequisite for…”
    Get full text
    Journal Article
  12. 12

    Magnetostrictive bilayer sensors—a survey by Mehnen, L., Kaniusas, E., Kosel, J., Téllez-Blanco, J.C., Pfützner, H., Meydan, T., Vázquez, M., Rohn, M., Malvicino, C., Marquardt, B.

    Published in Journal of alloys and compounds (28-04-2004)
    “…This paper concerns a new generation of bilayer materials as a basic element for multi-functional sensor families, consisting of a magnetostrictive layer (ML)…”
    Get full text
    Journal Article Conference Proceeding
  13. 13

    Non-contact detection of magnetoelastic bilayer position sensors by Kosel, J., Pfützner, H., Mehnen, L., Kaniusas, E., Meydan, T., Vázquez, M., Rohn, M., Merlo, A.M., Marquardt, B.

    Published in Sensors and actuators. A. Physical. (23-09-2005)
    “…The paper concerns the contactless position sensing by the help of magnetoelastic bilayers, a novel multifunctional mechanic sensor element. The bilayer is…”
    Get full text
    Journal Article
  14. 14

    A magnetostrictive acceleration sensor for registration of chest wall displacements by Kaniusas, E., Mehnen, L., Krell, C., Pfützner, H.

    “…The present study concerns a novel acceleration sensor built up using a bimetallic strip with one freely oscillating end. The strip consists of a…”
    Get full text
    Journal Article
  15. 15

    Optimisation of sensitivity and time constant of thermal sensors based on magnetoelastic amorphous bilayers by Kaniusas, E, Pfützner, H, Mehnen, L, Kosel, J, Téllez-Blanco, J.C, Mulasalihovic, E, Meydan, T, Vázquez, M, Rohn, M, Malvicino, C, Marquardt, B

    Published in Journal of alloys and compounds (28-04-2004)
    “…The paper concerns bilayers as thermal sensors which consist of a magnetostrictive amorphous layer (ML) glued on a nonmagnetic metal counter layer (CL)…”
    Get full text
    Journal Article Conference Proceeding
  16. 16

    Stimulation Pattern Efficiency in Percutaneous Auricular Vagus Nerve Stimulation: Experimental Versus Numerical Data by Kaniusas, Eugenijus, Samoudi, Amine Mohammed, Kampusch, Stefan, Bald, Katarzyna, Tanghe, Emmeric, Martens, Luc, Joseph, Wout, Szeles, Jozsef Constantin

    “…Objective: Percutaneous electrical stimulation of the auricular vagus nerve (pVNS) is an electroceutical technology. The selection of stimulation patterns is…”
    Get full text
    Journal Article
  17. 17
  18. 18

    Magnetoelastic skin curvature sensor for biomedical applications by Kaniusas, E., Pfutzner, H., Mehnen, L., Kosel, J., Varoneckas, G., Alonderis, A., Meydan, T., Vizquez, M., Rohn, M., Merlo, A.M., Marquardt, B.

    Published in Proceedings of IEEE Sensors, 2004 (2004)
    “…The present paper concerns the versatile applicability of a novel skin curvature sensor family for multiparametric monitoring of physiological parameters. The…”
    Get full text
    Conference Proceeding
  19. 19

    Magnetostrictive bilayer sensors [multifunction sensors] by Mehnen, L., Kaniusas, E., Kosel, J., Pfutzner, H., Meydan, T., Vazquez, M., Rohn, M., Merlo, A., Marquardt, B.

    Published in Proceedings of IEEE Sensors, 2004 (2004)
    “…This paper concerns a new generation of bilayer materials with controlled magnetic behaviour as a basic element for multi-functional sensor families. The…”
    Get full text
    Conference Proceeding
  20. 20

    Fully Implantable Multi-Channel Measurement System for Acquisition of Muscle Activity by Lewis, S., Russold, M., Dietl, H., Ruff, R., Audi, J. M. C., Hoffmann, K-P, Abu-Saleh, L., Schroeder, D., Krautschneider, W. H., Westendorff, S., Gail, A., Meiners, T., Kaniusas, E.

    “…This paper presents intramuscular electromyogram (EMG) signals obtained with a fully implantable measurement system that were recorded during goal directed arm…”
    Get full text
    Journal Article