Search Results - "Kamima, T."

  • Showing 1 - 11 results of 11
Refine Results
  1. 1

    SU-F-T-288: Impact of Trajectory Log Files for Clarkson-Based Independent Dose Verification of IMRT and VMAT by Takahashi, R, Kamima, T, Tachibana, H

    Published in Medical physics (Lancaster) (01-06-2016)
    “…Purpose: To investigate the effect of the trajectory files from linear accelerator for Clarkson-based independent dose verification in IMRT and VMAT plans…”
    Get full text
    Journal Article
  2. 2

    Prediction of Late Xerostomia after Radiotherapy by Integrating Dosiomics and Conventional Predictive Factors in Patients With Oropharyngeal Cancer by Ikarashi, A., Murakami, Y., Toshiyasu, T., Yoshioka, M., Kamima, T., Tokumasu, K., Nakano, M., Hashimoto, T., Oguchi, M., Yoshioka, Y.

    “…Xerostomia (dry mouth) is one of the main toxicities after radiotherapy in patients with oropharyngeal cancer. Although the mean dose to the parotid glands is…”
    Get full text
    Journal Article
  3. 3
  4. 4

    Can Dosiomics Features Be Relevant Predictive Factors for Biochemical Recurrence After Radiotherapy in Prostate Cancer Patients? by Murakami, Y., Soyano, T., Kozuka, T., Ushijima, M., Koizumi, Y., Miyauchi, H., Kaneko, M., Nakano, M., Kamima, T., Hashimoto, T., Oguchi, M., Yoshioka, Y.

    “…Radiotherapy is one of the main treatment strategies for localized prostate cancer. Although several patients receive external radiotherapy, the relationships…”
    Get full text
    Journal Article
  5. 5

    SU‐E‐T‐505: CT‐Based Independent Dose Verification for RapidArc Plan as a Secondary Check by Tachibana, H, Kamima, T, Takahashi, R, Baba, H

    Published in Medical physics (Lancaster) (01-06-2014)
    “…Purpose: To design and develop a CT‐based independent dose verification for the RapidArc plan and also to show the effectiveness of inhomogeneous correction in…”
    Get full text
    Journal Article
  6. 6

    SU‐E‐T‐32: A Feasibility Study of Independent Dose Verification for IMAT by Kamima, T, Takahashi, R, Baba, H, Yamashita, M, Sugawara, Y, Sato, Y, Tachibana, H

    Published in Medical physics (Lancaster) (01-06-2015)
    “…Purpose: To assess the feasibility of the independent dose verification (Indp) for intensity modulated arc therapy (IMAT). Methods: An independent dose…”
    Get full text
    Journal Article
  7. 7

    SU-F-T-609: Impact of Dosimetric Variation for Prescription Dose Using Analytical Anisotropic Algorithm (AAA) in Lung SBRT by Kawai, D, Takahashi, R, Kamima, T, Baba, H, Yamamoto, T, Kubo, Y, Ishibashi, S, Higuchi, Y, Tani, K, Tachibana, H

    Published in Medical physics (Lancaster) (01-06-2016)
    “…Purpose: Actual irradiated prescription dose to patients cannot be verified. Thus, independent dose verification and second treatment planning system are used…”
    Get full text
    Journal Article
  8. 8

    SU‐E‐T‐49: A Multi‐Institutional Study of Independent Dose Verification for IMRT by Baba, H, Kamima, T, Takahashi, R, Kawai, D, Sugawara, Y, Yamamoto, T, Sato, A, Yamashita, M, Tachibana, H

    Published in Medical physics (Lancaster) (01-06-2015)
    “…Purpose: AAPM TG114 does not cover the independent verification for IMRT. We conducted a study of independent dose verification for IMRT in seven institutes to…”
    Get full text
    Journal Article
  9. 9

    SU‐E‐T‐50: A Multi‐Institutional Study of Independent Dose Verification Software Program for Lung SBRT by Kawai, D, Takahashi, R, Kamima, T, Baba, H, Yamamoto, T, Kubo, Y, Ishibashi, S, Higuchi, Y, Takahashi, H, Tachibana, H

    Published in Medical physics (Lancaster) (01-06-2015)
    “…Purpose: The accuracy of dose distribution depends on treatment planning system especially in heterogeneity‐region. The tolerance level (TL) of the secondary…”
    Get full text
    Journal Article
  10. 10

    SU-F-T-494: A Multi-Institutional Study of Independent Dose Verification Using Golden Beam Data by Itano, M, Tachibana, R, Yamashita, M, Shimizu, H, Sugawara, Y, Kotabe, K, Kamima, T, Takahashi, R, Ishibashi, S, Uchida, Y, Yamazaki, T, Tachibana, H

    Published in Medical physics (Lancaster) (01-06-2016)
    “…Purpose: In general, beam data of individual linac is measured for independent dose verification software program and the verification is performed as a…”
    Get full text
    Journal Article
  11. 11

    SU‐E‐T‐48: A Multi‐Institutional Study of Independent Dose Verification for Conventional, SRS and SBRT by Takahashi, R, Tachibana, H, Kamima, T, Itano, M, Yamazaki, T, Ishibashi, S, Higuchi, Y, Shimizu, H, Yamamoto, T, Yamashita, M, Baba, H, Sugawara, Y, Sato, A, Nishiyama, S, Kawai, D, Miyaoka, S

    Published in Medical physics (Lancaster) (01-06-2015)
    “…Purpose: To show the results of a multi‐institutional study of the independent dose verification for conventional, Stereotactic radiosurgery and body…”
    Get full text
    Journal Article