Search Results - "KOBETIC, R"

Refine Results
  1. 1
  2. 2

    Design of a Variable Constraint Hip Mechanism for a Hybrid Neuroprosthesis to Restore Gait After Spinal Cord Injury by To, C.S., Kobetic, R., Schnellenberger, J.R., Audu, M.L., Triolo, R.J.

    Published in IEEE/ASME transactions on mechatronics (01-04-2008)
    “…A variable constraint hip mechanism (VCHM) has been developed for a hybrid neuroprosthesis system (HNP) to provide postural stability and uninhibited sagittal…”
    Get full text
    Journal Article
  3. 3

    Simulation of a functional neuromuscular stimulation powered mechanical gait orthosis with coordinated joint locking by To, C.S., Kirsch, R.F., Kobetic, R., Triolo, R.J.

    “…The purpose of this study was to examine a hybrid orthosis system (HOS) for walking after spinal-cord injury (SCI) that coordinates the mechanical locking and…”
    Get full text
    Journal Article
  4. 4

    The use of selective electrical stimulation of the quadriceps to improve standing function in paraplegia by Uhlir, J.P., Triolo, R.J., Kobetic, R.

    “…Persons with spinal cord injury (SCI) can benefit significantly from functional neuromuscular stimulation (FNS) systems for standing if manual tasks can be…”
    Get full text
    Journal Article
  5. 5
  6. 6

    Walking with a hybrid orthosis system by FERGUSON, K, POLANDO, G, KOBETIC, R, TRIOLO, R, MARSOLAIS, E

    Published in Spinal cord (01-11-1999)
    “…The purpose of this case study was to determine the functional effectiveness of the hybrid orthosis system (HOS) for sit-to-stand and walking compared with the…”
    Get full text
    Journal Article
  7. 7

    Functional electrical stimulation for walking in paraplegia by Marsolais, E B, Kobetic, R

    “…In paraplegic subjects who had functional transection of the spinal cord at a level between the fourth and the eleventh thoracic vertebra, independent…”
    Get full text
    Journal Article
  8. 8

    Energy Transfer in Bichromophoric Molecules:  The Effect of Symmetry and Donor/Acceptor Energy Gap by Yip, W. T, Levy, Donald H, Kobetic, Renata, Piotrowiak, Piotr

    “…The dependence of the rate of singlet excitation transfer on the donor−acceptor energy gap was investigated in bichromophoric spiranes with symmetry-forbidden…”
    Get full text
    Journal Article
  9. 9

    The Case Western Reserve University Hybrid Gait Orthosis by Marsolais, E. B., Kobetic, R., Polando, G., Ferguson, K., Tashman, S., Gaudio, R., Nandurkar, S., Lehneis, H. R.

    Published in The journal of spinal cord medicine (01-01-2000)
    “…Six individuals with paraplegia and injury levels from C-1 through T-12 participated in a study to evaluate the functional capabilities of a hybrid gait…”
    Get full text
    Journal Article
  10. 10

    Implantation techniques and experience with percutaneous intramuscular electrodes in the lower extremities by Marsolais, E B, Kobetic, R

    “…Innervated paralyzed muscles have been implanted with temporary percutaneous intramuscular electrodes in order to allow selective stimulation of as many…”
    Get full text
    Journal Article
  11. 11

    Development of a practical electrical stimulation system for restoring gait in the paralyzed patient by Marsolais, E B, Kobetic, R

    Published in Clinical orthopaedics and related research (01-08-1988)
    “…A percutaneous functional neuromuscular stimulation (FNS) system is being developed for restoring function in the lower extremities of spinal cord injured…”
    Get more information
    Journal Article
  12. 12

    Ambulation After Incomplete Spinal Cord Injury With EMG-Triggered Functional Electrical Stimulation by Dutta, Anirban, Kobetic, Rudi, Triolo, Ronald J.

    “…Individuals with incomplete spinal cord injury (iSCI) retain some control of the partially paralyzed muscles, necessitating careful integration of functional…”
    Get full text
    Journal Article
  13. 13

    Muscle selection and walking performance of multichannel FES systems for ambulation in paraplegia by Kobetic, R., Triolo, R.J., Marsolais, E.B.

    “…A minimal set of muscles (8 to 16) were identified as candidates for implantation in a clinical system to provide walking function to individuals with complete…”
    Get full text
    Journal Article
  14. 14

    Control of functional neuromuscular stimulation systems for standing and locomotion in paraplegics by Chizek, H.J., Kobetic, R., Marsolais, E.B., Abbas, J.J., Donner, I.H., Simon, E.

    Published in Proceedings of the IEEE (01-09-1988)
    “…The authors adopt a control-systems perspective in reviewing past applications of functional neuromuscular stimulation for providing lower extremity motor…”
    Get full text
    Journal Article
  15. 15

    Finite State Control of a Variable Impedance Hybrid Neuroprosthesis for Locomotion After Paralysis by Bulea, Thomas C., Kobetic, Rudi, Audu, Musa L., Schnellenberger, John R., Triolo, Ronald J.

    “…We have previously reported on a novel variable impedance knee mechanism (VIKM). The VIKM was designed as a component of a hybrid neuroprosthesis to regulate…”
    Get full text
    Journal Article
  16. 16

    Development and operation of portable and laboratory electrical stimulation systems for walking in paraplegic subjects by Borges, G., Ferguson, K., Kobetic, R.

    “…Two stimulation systems designed for use in functional neuromuscular stimulation of paralyzed people are discussed. One is portable and one is a nonportable…”
    Get full text
    Journal Article
  17. 17

    Augmentation of transfers for a quadriplegic patient using an implanted FNS system. Case report by Marsolais, E B, Scheiner, A, Miller, P C, Kobetic, R, Daly, J J

    Published in Paraplegia (01-08-1994)
    “…A 22 year old man with incomplete quadriplegia (C6-7) was unable to perform either a sliding or a pivot transfer. He was instrumented with an implanted…”
    Get full text
    Journal Article
  18. 18

    Functional walking in paralyzed patients by means of electrical stimulation by Marsolais, E B, Kobetic, R

    Published in Clinical orthopaedics and related research (01-05-1983)
    “…Three partially paralyzed patients were unable to walk even after maximal rehabilitation attempts at a major rehabilitation center. One 36-year-old man had…”
    Get more information
    Journal Article
  19. 19

    Hybrid orthosis system with a variable hip coupling mechanism by To, C.S., Kobetic, R., Triolo, R.J.

    “…Existing reciprocating gait orthoses, to help restore gait to individuals with paraplegia, have a fixed 1:1 hip flexion/extension coupling ratios (FECR),…”
    Get full text
    Conference Proceeding Journal Article
  20. 20

    Implanted functional electrical stimulation system for mobility in paraplegia: a follow-up case report by Kobetic, R., Sharma, M., Triolo, R.J., Uhlir, J.P., Bieri, C., Wibowo, M., Polando, G., Marsolais, E.B., Davis, J.A., Ferguson, K.A.

    “…A 16-channel functional electrical stimulation (FES) system has been implanted in a person with T10 paraplegia for over a year. The system consists of two…”
    Get full text
    Journal Article