Safety and Efficacy of a Totally Subcutaneous Implantable-Cardioverter Defibrillator
Published in Circulation (New York, N.Y.) (27-08-2013)“…BACKGROUND—The most frequent complications associated with implantable cardioverter-defibrillators (ICDs) involve the transvenous leads. A subcutaneous…”
Get full text
Journal Article -
2
On-treatment comparison between corrective His bundle pacing and biventricular pacing for cardiac resynchronization: A secondary analysis of the His-SYNC Pilot Trial
Published in Heart rhythm (01-12-2019)“…The His-SYNC pilot trial was the first randomized comparison between His bundle pacing in lieu of a left ventricular lead for cardiac resynchronization therapy…”
Get full text
Journal Article -
3
Head-To-Head Comparison of Arrhythmia Discrimination Performance of Subcutaneous and Transvenous ICD Arrhythmia Detection Algorithms: The START Study
Published in Journal of cardiovascular electrophysiology (01-04-2012)“…Arrhythmia Detection with S‐ICD Versus Transvenous ICDs. Background: The development of a totally subcutaneous implantable defibrillator (S‐ICD) system…”
Get full text
Journal Article -
4
Subcutaneous implantable cardioverter-defibrillator Post-Approval Study: Clinical characteristics and perioperative results
Published in Heart rhythm (01-10-2017)“…The subcutaneous implantable cardioverter-defibrillator (S-ICD) was developed to reduce short- and long-term complications associated with transvenous ICD…”
Get full text
Journal Article -
5
Evaluation of subcutaneous ICD early performance in hypertrophic cardiomyopathy from the pooled EFFORTLESS and IDE cohorts
Published in Heart rhythm (01-05-2016)“…Background The subcutaneous implantable cardioverter-defibrillator (S-ICD) is a potential alternative to transvenous systems in hypertrophic cardiomyopathy…”
Get full text
Journal Article -
6
The extravascular implantable cardioverter‐defibrillator: The pivotal study plan
Published in Journal of cardiovascular electrophysiology (01-09-2021)“…Background Transvenous implantable cardioverter defibrillators (TV ICD) provide life‐saving therapy for millions of patients worldwide. However, they are…”
Get full text
Journal Article -
7
Use of an electrocardiographic screening tool to determine candidacy for a subcutaneous implantable cardioverter-defibrillator
Published in Heart rhythm (01-08-2014)“…Background An electrocardiographic (ECG) screening test has been developed to identify patients being considered for a totally subcutaneous implantable…”
Get full text
Journal Article -
8
Implementation of an intravenous sotalol initiation protocol: Implications for feasibility, safety, and length of stay
Published in Journal of cardiovascular electrophysiology (01-03-2023)“…Introduction Oral sotalol initiation requires a multiple‐day, inpatient admission to monitor for QT prolongation during loading. A 1‐day intravenous (IV)…”
Get full text
Journal Article -
9
Subcutaneous implantable cardioverter-defibrillator implantation position predicts successful defibrillation in obese and non-obese patients
Published in Journal of interventional cardiac electrophysiology (03-01-2023)“…Subcutaneous implantable cardioverter-defibrillators (S-ICD) are an alternative to transvenous ICDs for patients without a need for cardiac pacing. Obese…”
Get full text
Journal Article -
10
Update in Cardiac Pacing
Published in Arrhythmia & electrophysiology review (01-07-2019)“…Initial efforts to artificially stimulate the heart were borne out of a necessity to prevent catastrophic bradycardic events. The initial pacemaker systems…”
Get full text
Journal Article -
11
Bronchial effects of cryoballoon ablation for atrial fibrillation
Published in Heart rhythm (2017)“…Background Damage to extracardiac structures, including the esophagus and phrenic nerve, is a known complication of cryoballoon ablation (CBA) during pulmonary…”
Get full text
Journal Article -
12
Novel coronavirus 19 (COVID-19) associated sinus node dysfunction: a case series
Published in European heart journal : case reports (01-10-2020)“…Abstract Background Novel coronavirus-19 disease (COVID-19) is associated with significant cardiovascular morbidity and mortality. To date, there have not been…”
Get full text
Journal Article -
13
Conduction recovery following pacemaker implantation after transcatheter aortic valve replacement
Published in Pacing and clinical electrophysiology (01-02-2019)“…Background Transcatheter aortic valve replacement (TAVR) is increasingly used to treat severe aortic stenosis. A frequent complication of TAVR is high‐grade or…”
Get full text
Journal Article -
14
Sex Differences in Ablation Strategy, Lesion Sets, and Complications of Catheter Ablation for Atrial Fibrillation: An Analysis From the GWTG-AFIB Registry
Published in Circulation. Arrhythmia and electrophysiology (01-11-2021)“…When presenting for atrial fibrillation (AF) ablation, women, compared with men, tend to have more nonpulmonary vein triggers and advanced atrial disease…”
Get full text
Journal Article -
15
The Use of Intracardiac Echocardiography and Other Intracardiac Imaging Tools to Guide Noncoronary Cardiac Interventions
Published in Journal of the American College of Cardiology (09-06-2009)“…The limitations of standard fluoroscopy have led to the development of improved imaging techniques to guide noncoronary cardiac interventions. Imaging tools…”
Get full text
Journal Article -
16
Electrogram morphology recurrence patterns during atrial fibrillation
Published in Heart rhythm (01-11-2014)“…Background Traditional mapping of atrial fibrillation (AF) is limited by changing electrogram morphologies and variable cycle lengths. Objective We tested the…”
Get full text
Journal Article -
17
Use of Atrial Fibrillation Electrograms and T1/T2 Magnetic Resonance Imaging to Define the Progressive Nature of Molecular and Structural Remodeling: A New Paradigm Underlying the Emergence of Persistent Atrial Fibrillation
Published in Journal of the American Heart Association (05-03-2024)“…The temporal progression states of the molecular and structural substrate in atrial fibrillation (AF) are not well understood. We hypothesized that these can…”
Get full text
Journal Article -
18
Use of a discrimination algorithm to reduce inappropriate shocks with a subcutaneous implantable cardioverter-defibrillator
Published in Heart rhythm (01-08-2014)“…Background The subcutaneous implantable cardioverter-defibrillator system (S-ICD) uses a novel detection algorithm previously shown to discriminate induced…”
Get full text
Journal Article -
19
Pulmonary vein isolation for paroxysmal and persistent atrial fibrillation
Published in Circulation (New York, N.Y.) (05-03-2002)“…The pulmonary veins (PVs) have been demonstrated to often play an important role in generating atrial fibrillation (AF). The purpose of this study was to…”
Get full text
Journal Article -
20
The Safety of Cardiac and Thoracic Magnetic Resonance Imaging in Patients with Cardiac Implantable Electronic Devices
Published in Academic radiology (01-12-2016)“…Rationale and Objectives Studies reporting the safety of magnetic resonance imaging (MRI) in patients with a cardiac implantable electronic device (CIED) have…”