Search Results - "KIKUGAWA, Daiki"
-
1
Control Strategy for Rotary Blood Pumps
Published in Artificial organs (01-05-2001)“…: The control strategy for ventricular support with a centrifugal blood pump was examined in this study. The control parameter was the pump rpm that determines…”
Get full text
Journal Article -
2
Analysis of the relationship between left ventricular pressure and motor current for evaluation of native cardiac function during left ventricular support with a centrifugal blood pump
Published in Journal of artificial organs (01-12-2001)“…Control of the ventricular assist device (VAD) for native heart preservation should be attempted, and the VAD could be one strategy for dealing with the…”
Get full text
Journal Article -
3
Evaluation of Cardiac Function During Left Ventricular Assist by a Centrifugal Blood Pump
Published in Artificial organs (01-08-2000)“…: In this study, the effects on varying cardiac function during a left ventricular (LV) bypass from the apex to the descending aorta using a centrifugal blood…”
Get full text
Journal Article -
4
Motor Current Waveforms as an Index for Evaluation of Native Cardiac Function During Left Ventricular Support with a Centrifugal Blood Pump
Published in Artificial organs (01-09-2001)“…: Control of ventricular assist devices (VADs) for native heart preservation should be attempted, and it could be one strategy for dealing with the shortage of…”
Get full text
Journal Article -
5
Long-term Results of Emergency Coronary Artery Bypass Grafting
Published in Japanese Heart Journal (1996)“…During a 20-year period, 364 patients underwent coronary artery bypass grafting (CABG) for the treatment of ischemic heart disease. Among these patients, 28…”
Get full text
Journal Article Conference Proceeding -
6
Changes in Patterns of Left Ventricular Hypertrophy After Aortic Valve Replacement for Aortic Stenosis and Regurgitation with St. Jude Medical Cardiac Valves
Published in Artificial organs (01-12-2000)“…: In this study, we analyzed the extent and pattern of regression of left ventricular (LV) hypertrophy after aortic valve replacement in patients with aortic…”
Get full text
Journal Article -
7
Evaluation of an Implantable Motor-Driven Left Ventricular Assist Device
Published in Artificial organs (01-03-1999)“…A console based implantable motor‐driven left ventricular assist device (LVAD) was developed and tested. Ten sheep weighing 42–73 kg (mean, 54.4 kg) were used…”
Get full text
Journal Article -
8
Left Ventricular Mass Regression After Implantation of St. Jude Medical Cardiac Valves in Small Aortic Roots
Published in Artificial organs (01-09-1998)“…In this study, we analyzed the extent of regression of left ventricular hypertrophy in patients who received small St. Jude Medical (SJM) aortic valves and…”
Get full text
Journal Article -
9
In vitro and in vivo testing of an implantable motor-driven left ventricular assist device
Published in Artificial organs (01-02-1996)“…A totally implantable motor-driven left ventricular assist device (LVAD) has been developed and tested. The performance of this LVAD was tested in a mock…”
Get more information
Journal Article