Search Results - "KAVESH, Neal G"
-
1
Dual-chamber versus single-chamber detection enhancements for implantable defibrillator rhythm diagnosis : The detect supraventricular tachycardia study
Published in Circulation (New York, N.Y.) (27-06-2006)“…Delivery of inappropriate shocks caused by misdetection of supraventricular tachycardia (SVT) remains a substantial complication of implanted…”
Get full text
Journal Article -
2
Clinical Predictors of Transvenous Biphasic Defibrillation Thresholds
Published in The American journal of cardiology (15-06-1997)“…Transvenous lead systems have become routine for defibrillator placement. However, previous studies of clinical predictors of an adequate nonthoracotomy…”
Get full text
Journal Article -
3
Biphasic Waveforms Prevent the Chronic Rise of Defibrillation Thresholds With a Transvenous Lead System
Published in Journal of the American College of Cardiology (01-07-1997)“…Objectives. The purpose of this study was to compare chronic changes in monophasic and biphasic defibrillation thresholds using a uniform transvenous lead…”
Get full text
Journal Article Conference Proceeding -
4
Clinical Predictors of Transvenous Defibrillation Energy Requirements
Published in The American journal of cardiology (15-01-1997)“…Nonthoracotomy and, more recently, transvenous lead systems have become routine for initial implantable cardioverter-defibrillator (ICD) placement. Previous…”
Get full text
Journal Article -
5
Chronic Rise in Monophasic Defibrillation Thresholds With a Transvenous Lead System
Published in The American journal of cardiology (15-02-1997)“…This study was a prospective evaluation of chronic changes of defibrillation thresholds in 31 clinically stable patients with a single transvenous lead,…”
Get full text
Journal Article -
6
Comparison of Power- and Temperature-Guided Radiofrequency Modification of the Atrioventricular Node
Published in The American journal of cardiology (01-12-1997)“…The purpose of this study was to compare the performance and clinical outcome of radiofrequency ablation of the substrate of atrioventricular (AV) nodal…”
Get full text
Journal Article -
7
Enhanced detection of distinguishing features in signal-averaged electrocardiograms from patients with ventricular tachycardia by combined spatial and spectral analyses of entire cardiac cycle
Published in Circulation (New York, N.Y.) (01-07-1994)“…Signals generated by myocardium responsible for ventricular tachycardia (VT) contribute to the entire QRS complex, ST segment, and T wave and are spatially…”
Get full text
Journal Article -
8
Effect of Heart Rate on T Wave Alternans
Published in Journal of cardiovascular electrophysiology (01-07-1998)“…Heart Rate and T Wave Alternans. Introduction: T wave alternans (TWA) is a promising technique for detecting arrhythmia vulnerability. Previous studies in…”
Get full text
Journal Article -
9
The Effect of Procainamide on T Wave Alternans
Published in Journal of cardiovascular electrophysiology (01-05-1999)“…Procainamide and T‐Wave Alternans. Introduction: The measurement of microvolt level T wave alternans (TWA) is a technique for detecting arrhythmia…”
Get full text
Journal Article -
10
A comparison of pectoral and abdominal transvenous defibrillator implantation : Analysis of costs and outcomes
Published in Journal of interventional cardiac electrophysiology (01-12-1998)“…Traditionally cardioverter-defibrillator implantation was performed by surgeons under general anesthesia. However, with advances in lead and pulse generator…”
Get full text
Journal Article -
11
Effect of biphasic waveforms on transvenous defibrillation thresholds in patients with coronary artery disease
Published in The American journal of cardiology (15-10-1997)“…In summary, we compared monophasic and biphasic transvenous DFT in 19 patients and observed a 27% reduction of DFT with the biphasic waveform despite…”
Get full text
Journal Article -
12
Signal-Averaged Isoharmonic Body Surface Maps of Patients with Ischemic Cardiomyopathy
Published in Journal of cardiovascular electrophysiology (01-02-2000)“…Signal‐Averaged Body Surface Maps. Introduction:Prevention of sudden arrhythmic cardiac death depends on accurate identification of individuals at high risk…”
Get full text
Journal Article -
13
Intravenous Amiodarone Suppression of Electrical Storm Refractory to Chronic Oral Amiodarone
Published in Pacing and clinical electrophysiology (01-04-1999)“…We report the case of an electrical storm in a cardiac arrest survivor with an ICD, in whom chronic oral amiodarone failed to suppress ventricular arrhythmias,…”
Get full text
Journal Article -
14
Phase and group-delay characteristics of signal-averaged electrocardiograms from patients with ventricular tachycardia
Published in IEEE transactions on biomedical engineering (01-01-1995)“…Fourier analysis of the signal-averaged ECG (SAECG) has previously revealed significant differences in magnitude spectra that differentiate patients with…”
Get full text
Journal Article -
15
Spectral analysis of the cardiac cycle of signal-averaged Frank leads from patients with ventricular tachycardia
Published in Journal of electrocardiology (1994)“…Identification of the spectral features in electrocardiograms that distinguish patients prone to ventricular tachycardia (VT) is a prerequisite to increasing…”
Get more information
Journal Article -
16
-
17
The combined toxicity of azidothymidine and antimycobacterial agents. A retrospective study
Published in The American review of respiratory disease (01-05-1989)“…Eight patients being treated for tuberculosis prior to starting azidothymidine therapy (study group) were compared with 56 patients who were treated with…”
Get more information
Journal Article