Search Results - "K N, Chethan"
-
1
Wear estimation of trapezoidal and circular shaped hip implants along with varying taper trunnion radiuses using finite element method
Published in Computer methods and programs in biomedicine (01-11-2020)“…•Wear in the articulating surfaces is the main reason for the revision surgery of hip implants.•ANSYS is used to estimate the linear wear rate at the taper…”
Get full text
Journal Article -
2
Finite Element Analysis of Different Hip Implant Designs along with Femur under Static Loading Conditions
Published in Journal of biomedical physics and engineering (01-10-2019)“…The hip joint is the largest joint after the knee, which gives stability to the whole human structure. The hip joint consists of a femoral head which…”
Get full text
Journal Article -
3
Evolution of different designs and wear studies in total hip prosthesis using finite element analysis: A review
Published in Cogent engineering (31-12-2022)“…In replacement surgery of the hip joint, an implant is replaced into the natural femur which recreates the articulation and functionally of a natural joint…”
Get full text
Journal Article -
4
Static structural analysis of the effect of change in femoral head sizes used in Total Hip Arthroplasty using finite element method
Published in Cogent engineering (31-12-2022)“…The total hip prosthesis is considered one of the greatest advancements in orthopaedic surgery in the early 20 th century. In hip implant replacement, the stem…”
Get full text
Journal Article -
5
Wear estimation at the contact surfaces of oval shaped hip implants using finite element analysis
Published in Cogent engineering (31-12-2023)“…The hip joint is one of the most essential joints for transmitting weights to the lower abdomen during day-to-day activities. Loosening of hip implants is…”
Get full text
Journal Article -
6
A method for estimating the contact area of a dual-mobility total hip prosthesis
Published in AIP advances (01-01-2024)“…The term “contact area” refers to the total surface area of two entities in direct physical touch. When discussing an artificial hip joint, “contact area”…”
Get full text
Journal Article -
7
In-silico investigation of 4-nitro-N-1H-pyrazol-3-ylbenzamide towards its potential use against SARS-CoV-2: a DFT, molecular docking and molecular dynamics study
Published in Journal of biomolecular structure & dynamics (09-12-2024)“…In the present research work, we report the synthesis and characterization of novel pyrazole derivative obtained by the condensation reaction of 4-nitro…”
Get full text
Journal Article -
8
Investigating the Influence of All-Ceramic Prosthetic Materials on Implants and Their Effect on the Surrounding Bone: A Finite Element Analysis
Published in Prosthesis (Basel, Switzerland) (01-01-2024)“…This study aims to assess and compare the impact of Monolithic Zirconia (MZ) and In-Ceram Zirconia (ZP) superstructures on stress distribution within implants…”
Get full text
Journal Article -
9
Exploring acoustic properties of banana fiber composites with elastomeric filler through a computational approach
Published in Materials research express (01-01-2024)“…Abstract In recent years, there has been a significant increase in the use of natural fibers as reinforcements in composites. This trend is mainly driven by…”
Get full text
Journal Article -
10
Optimized trapezoidal-shaped hip implant for total hip arthroplasty using finite element analysis
Published in Cogent engineering (01-01-2020)“…Hip implants consist of a stem, femoral head, acetabular cup, and backing cup. There is a wide variety of sizes and lengths. Their adaptability is limited…”
Get full text
Journal Article -
11
Evaluating Angled Abutments: Three-Dimensional Finite Element Stress Analysis of Anterior Maxillary Implants
Published in Prosthesis (Basel, Switzerland) (01-04-2024)“…Restorative dentistry is the repairing of damaged teeth and restoring oral health and function. Dental implants are typically placed within the cortical bone…”
Get full text
Journal Article -
12
Exploring Stresses in Mandibular Jawbone during Implant Insertion: A Three-Dimensional Explicit Dynamic Analysis
Published in Prosthesis (Basel, Switzerland) (01-04-2024)“…In dental implant insertion, an artificial foundation is prepared for the prosthetic device, which involves the surgical positioning of the implant in the jaw…”
Get full text
Journal Article -
13
Optimizing stress distribution in dental air abrasion through design of experiments: a finite element analysis
Published in Cogent engineering (31-12-2024)“…This investigation delves into the dynamics of stress distribution during particle impacts on Incisor teeth, revealing the significant roles of particle size,…”
Get full text
Journal Article -
14
Conceptual design and analysis of a car bumper using finite element method
Published in Cogent engineering (01-01-2021)“…Due to intrinsic or extrinsic conditions, the number of car accidents has increased currently across the globe. Drivers must be assured that they can avoid…”
Get full text
Journal Article -
15
Computational investigation of various stem designs with different radial clearances in total hip arthroplasty
Published in Cogent engineering (29-12-2023)“…Hip implants are available in various shapes and sizes. This study aims to select the better hip implant stem design and the optimal material that can be used…”
Get full text
Journal Article -
16
Investigating dental structure response to air abrasion: a finite element analysis
Published in Materials research express (01-03-2024)“…Abstract Air abrasion particles, propelled by a compressed air stream, remove material from the tooth’s surface. The air abrasion parameter plays an important…”
Get full text
Journal Article -
17
Impact of obstruction size on ureter dynamics: A computational investigation
Published in Results in engineering (01-06-2024)“…Kidney stones, known medically as nephrolithiasis, present a significant health concern globally, particularly in regions such as India and the Middle East…”
Get full text
Journal Article -
18
Air-Abrasion in Dentistry: A Short Review of the Materials and Performance Parameters
Published in Journal of biomedical physics and engineering (01-02-2024)“…The selection of abrasive material and parameters of the Air-Abrasion device for a particular application is a crucial detail. However, there are no standard…”
Get full text
Journal Article -
19
Finite element analysis of hip implant with varying in taper neck lengths under static loading conditions
Published in Computer methods and programs in biomedicine (01-09-2021)“…•von Mises stresses and total deformation under different loading conditions are used to evaluate the performance of the implant.•ANSYS R-19.0 is used to…”
Get full text
Journal Article -
20
Wear estimation of hip implants with varying chamfer geometry at the trunnion junction: a finite element analysis
Published in Biomedical physics & engineering express (01-05-2023)“…The hip joint helps the upper body to transfer its weight to lower body. Along with age, there are various reasons for the degeneration of the hip joint. The…”
Get more information
Journal Article