Search Results - "Julyan, P.J."
-
1
EM algorithm system modeling by image-space techniques for PET reconstruction
Published in IEEE transactions on nuclear science (01-10-2003)“…Methodology for PET system modeling using image-space techniques in the expectation maximization (EM) algorithm is presented. The approach, applicable to both…”
Get full text
Journal Article -
2
One-pass list-mode EM algorithm for high-resolution 3-D PET image reconstruction into large arrays
Published in IEEE transactions on nuclear science (01-06-2002)“…High-resolution three-dimensional (3-D) positron emission tomography (PET) scanners with high count rate performance, such as the quad-high density avalanche…”
Get full text
Journal Article -
3
Noise Properties of Four Strategies for Incorporation of Scatter and Attenuation Information in PET Reconstruction Using the EM-ML Algorithm
Published in IEEE transactions on nuclear science (01-10-2006)“…Conventional methods for dealing with attenuation and scatter in PET can limit the reconstructed image quality, particularly if the attenuating medium is large…”
Get full text
Journal Article -
4
Accelerated list-mode EM algorithm
Published in IEEE transactions on nuclear science (01-02-2002)“…List-mode data preserves all sampling information in three-dimensional (3-D) PET imaging and can reduce storage requirements for short-time frame acquisitions…”
Get full text
Journal Article -
5
Adaptive correction of scatter and random events for 3-D backprojected PET data
Published in IEEE transactions on nuclear science (01-08-2001)“…Backprojected images offer compact and accurate storage of three-dimensional (3-D) positron emission tomography (PET) data and so are potentially very suited…”
Get full text
Journal Article -
6
Comparative Study With New Accuracy Metrics for Target Volume Contouring in PET Image Guided Radiation Therapy
Published in IEEE transactions on medical imaging (01-11-2012)“…The impact of positron emission tomography (PET) on radiation therapy is held back by poor methods of defining functional volumes of interest. Many new…”
Get full text
Journal Article -
7
Performance characteristics of a small animal PET camera for molecular imaging
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (01-04-2007)“…The performance of a novel type of animal PET camera, the quad High-Density Avalanche Chamber (HIDAC) was assessed for a non-rotating 16-module system. Spatial…”
Get full text
Journal Article -
8
SUVpeak: a new parameter for quantification of uptake in FDG PET
Published in Nuclear medicine communications (01-04-2004)Get full text
Journal Article -
9
Bias in iterative reconstruction of low-statistics PET data: Benefits of a resolution model
Published in 2009 IEEE Nuclear Science Symposium Conference Record (NSS/MIC) (01-10-2009)“…Ordered-subset expectation maximization (OSEM) is a widely used method of reconstructing PET data. Several authors have reported bias when reconstructing…”
Get full text
Conference Proceeding -
10
Evaluation of annexin V labelled with the positron emitter 124I for PET imaging of apoptosis
Published in Nuclear medicine communications (01-04-2004)Get full text
Journal Article -
11
Impact of Scatter Modeling Error on 3D Maximum Likelihood Reconstruction in PET
Published in 2006 IEEE Nuclear Science Symposium Conference Record (01-10-2006)“…In statistical image reconstruction for PET, the reconstructed image quality depends on the system matrix as well as the scatter correction method used,…”
Get full text
Conference Proceeding -
12
Region-based Efficiency Correction for the High-Resolution quad-HIDAC PET scanner
Published in 2006 IEEE Nuclear Science Symposium Conference Record (01-10-2006)“…The very high resolution quad-HIDAC PET scanner has four detector banks each with four planar high density avalanche chambers, capable of collecting billions…”
Get full text
Conference Proceeding -
13
High Accuracy Multiple Order Scatter Model for 3D Whole Body PET
Published in 2006 IEEE Nuclear Science Symposium Conference Record (01-10-2006)“…A technique for modelling multiple Compton scatter as the absolute probabilities which relate the image space to the projection space in 3D whole body PET…”
Get full text
Conference Proceeding -
14
Noise properties of four strategies for incorporation of scatter and attenuation information in PET reconstruction
Published in IEEE Symposium Conference Record Nuclear Science 2004 (2004)“…Conventional methods for dealing with attenuation and scatter can degrade the reconstructed image quality, particularly if the attenuating medium is large (as…”
Get full text
Conference Proceeding -
15
Towards an accurate voxel-based analytic unified scatter and attenuation system model for 3D PET
Published in IEEE Symposium Conference Record Nuclear Science 2004 (2004)“…A voxel-based approach to 3D PET analytic system modeling which projects the unit sphere of Klein-Nishina probabilities onto the cylindrical detection sphere,…”
Get full text
Conference Proceeding -
16
Regularized one-pass list-mode EM algorithm for high resolution 3D PET image reconstruction into large arrays
Published in 2001 IEEE Nuclear Science Symposium Conference Record (Cat. No.01CH37310) (01-01-2002)“…High resolution 3D PET scanners with high count rate performance, such as the quad-HIDAC, place new demands on image reconstruction algorithms due to the large…”
Get full text
Conference Proceeding -
17
An attenuation measurement technique for rotating planar detector positron tomographs
Published in Physics in medicine & biology (01-08-1997)“…This paper presents a new attenuation measurement technique suitable for rotating planar detector positron tomographs. Transmission measurements are made using…”
Get more information
Journal Article -
18
EM algorithm resolution modeling by image-space convolution for PET reconstruction
Published in 2002 IEEE Nuclear Science Symposium Conference Record (2002)“…A method for modeling and recovering resolution in the expectation maximization (EM) algorithm via two image-space convolutions per iteration is presented. The…”
Get full text
Conference Proceeding -
19
Adaptive correction of scatter and random events for 3D backprojected PET data
Published in 2000 IEEE Nuclear Science Symposium. Conference Record (Cat. No.00CH37149) (2000)“…Backprojected images offer compact and accurate storage of 3D PET data, and so are potentially very suited to high resolution 3D PET scanners when carrying out…”
Get full text
Conference Proceeding -
20
Quad-HIDAC PET: comparison of four image reconstruction techniques for high resolution imaging
Published in 2001 IEEE Nuclear Science Symposium Conference Record (Cat. No.01CH37310) (2001)“…The quad-HIDAC PET scanner offers unparalleled high resolution PET imaging capability (<1 mm), combined with notable count rate performance (400 kcps) and…”
Get full text
Conference Proceeding