Search Results - "Jolles, B.M."
-
1
Functional calibration procedure for 3D knee joint angle description using inertial sensors
Published in Journal of biomechanics (16-10-2009)“…Abstract Measurement of three-dimensional (3D) knee joint angle outside a laboratory is of benefit in clinical examination and therapeutic treatment…”
Get full text
Journal Article -
2
Ambulatory measurement of 3D knee joint angle
Published in Journal of biomechanics (01-01-2008)“…Abstract Three-dimensional measurement of joint motion is a promising tool for clinical evaluation and therapeutic treatment comparisons. Although many devices…”
Get full text
Journal Article -
3
In vivo electrochemical corrosion study of a CoCrMo biomedical alloy in human synovial fluids
Published in Acta biomaterialia (01-07-2015)“…[Display omitted] The present study was initiated with the aim to assess the in vivo electrochemical corrosion behaviour of CoCrMo biomedical alloys in human…”
Get full text
Journal Article -
4
A new approach to accurate measurement of uniaxial joint angles based on a combination of accelerometers and gyroscopes
Published in IEEE transactions on biomedical engineering (01-08-2005)“…A new method of measuring joint angle using a combination of accelerometers and gyroscopes is presented. The method proposes a minimal sensor configuration…”
Get full text
Journal Article -
5
Estimation and visualization of sagittal kinematics of lower limbs orientation using body-fixed sensors
Published in IEEE transactions on biomedical engineering (01-07-2006)“…A new method of estimating lower limbs orientations using a combination of accelerometers and gyroscopes is presented. The model is based on estimating the…”
Get full text
Journal Article -
6
Lateral wedges induce a pattern of changes in ambulatory lower-limb frontal-plane kinetics with individual dose-response
Published in Osteoarthritis and cartilage (01-04-2017)Get full text
Journal Article -
7
Lateral wedges induce subject-specific changes in knee kinetics and kinematics during walking
Published in Osteoarthritis and cartilage (01-04-2016)Get full text
Journal Article -
8
The effects of end-of-range grade A+ mobilisation following acute primary TKA
Published in Physiotherapy (01-05-2015)Get full text
Journal Article -
9
Lateral wedges induce changes in muscle activities that are not correlated to changes in knee adduction moment
Published in Osteoarthritis and cartilage (01-04-2015)Get full text
Journal Article -
10
T2 Relaxation Time Varies Within the Load-Bearing Regions of Non-OA Femoral Cartilage
Published in Osteoarthritis and cartilage (01-04-2017)Get full text
Journal Article -
11
Evaluation of a mixed approach combining stationary and wearable systems to monitor gait over long distance
Published in Journal of biomechanics (10-08-2010)“…Abstract Thanks to decades of research, gait analysis has become an efficient tool. However, mainly due to the price of the motion capture systems, standard…”
Get full text
Journal Article -
12
The knee smartphone-application goniometer is a more reliable tool than the standard goniometer in acute orthopaedic settings
Published in Physiotherapy (01-05-2015)Get full text
Journal Article -
13
Total hip arthroplasty using a cementless dual-mobility cup provides increased stability and favorable gait parameters at five years follow-up
Published in Orthopaedics & traumatology, surgery & research (01-02-2017)“…Abstract Background Rates of dislocation following primary total hip arthroplasty (THA) vary from 0.5 to 10%. Dual-mobility cups in THA demonstrate increased…”
Get full text
Journal Article -
14
A New Approach for Quantitative Analysis of Inter-Joint Coordination During Gait
Published in IEEE transactions on biomedical engineering (01-02-2008)“…A new method for quantitative analysis of interjoint coordination at various walking speeds is presented. The model imposed a parametric relationship among…”
Get full text
Journal Article -
15
A comparison between joint coordinate system and attitude vector for multi-segment foot kinematics
Published in Journal of biomechanics (26-07-2012)“…Abstract The joint angles of multi-segment foot models have been primarily described using two mathematical methods: the joint coordinate system and the…”
Get full text
Journal Article -
16
Effects of manual lymphatic drainage following total knee arthroplasty: a prospective randomised controlled trial
Published in Physiotherapy (01-05-2015)Get full text
Journal Article -
17
Smart instrumentation for determination of ligament stiffness and ligament balance in total knee arthroplasty
Published in Medical engineering & physics (01-06-2014)“…Abstract Ligament balance is an important and subjective task performed during total knee arthroplasty (TKA) procedure. For this reason, it is desirable to…”
Get full text
Journal Article -
18
Comparison of a dedicated body-worn inertial system and a smartphone for shoulder function and arm elevation evaluation
Published in Physiotherapy (01-05-2015)Get full text
Journal Article -
19
Validity of a straightforward shoulder function evaluation method using a smartphone
Published in Physiotherapy (01-05-2015)Get full text
Journal Article -
20