Search Results - "Jo Hong, Key"

Refine Results
  1. 1

    Feasibility study of portable multi-energy computed tomography with photon-counting detector for preclinical and clinical applications by Lee, Chang-Lae, Hong, Key Jo, Kim, Namwoo, Han, Kwanhee, Kim, Dongkyu, Jung, Hoe-Su, Lee, Sangmin, Park, Junyoung, Lee, Kyoung-Yong, Lee, Jee Eun, Choi, Yuna, Cho, Minkook

    Published in Scientific reports (23-11-2021)
    “…In this study, preclinical experiments were performed with an in-house developed prototypal photon-counting detector computed tomography (PCD CT) system. The…”
    Get full text
    Journal Article
  2. 2

    Tomographic image of prompt gamma ray from boron neutron capture therapy: A Monte Carlo simulation study by Yoon, Do-Kun, Jung, Joo-Young, Jo Hong, Key, Suk Suh, Tae

    Published in Applied physics letters (24-02-2014)
    “…Purpose of paper is to confirm the feasibility of acquisition of three dimensional single photon emission computed tomography image from boron neutron capture…”
    Get full text
    Journal Article
  3. 3

    GPU‐based prompt gamma ray imaging from boron neutron capture therapy by Yoon, Do‐Kun, Jung, Joo‐Young, Jo Hong, Key, Sil Lee, Keum, Suk Suh, Tae

    Published in Medical physics (Lancaster) (01-01-2015)
    “…Purpose: The purpose of this research is to perform the fast reconstruction of a prompt gamma ray image using a graphics processing unit (GPU) computation from…”
    Get full text
    Journal Article
  4. 4

    A Compact SPECT/CT System for Small Animal Imaging by Hong, K.J., Choi, Y., Lee, S.C., Lee, S.Y., Song, T.Y., Min, B.J., Jung, J.H., Choe, Y.S., Lee, K.-H., Kim, B.-T.

    Published in IEEE transactions on nuclear science (01-10-2006)
    “…A dual-modality compact SPECT/CT system for small animal imaging was developed. The SPECT system consisted of a pinhole collimator and continuous NaI(Tl)…”
    Get full text
    Journal Article
  5. 5

    A prototype MR insertable brain PET using tileable GAPD arrays by Hong, Key Jo, Choi, Yong, Jung, Jin Ho, Kang, Jihoon, Hu, Wei, Lim, Hyun Keong, Huh, Yoonsuk, Kim, Sangsu, Jung, Ji Woong, Kim, Kyu Bom, Song, Myung Sung, Park, Hyun-wook

    Published in Medical physics (Lancaster) (01-04-2013)
    “…Purpose: The aim of this study was to develop a prototype magnetic resonance (MR)-compatible positron emission tomography (PET) that can be inserted into a MR…”
    Get full text
    Journal Article
  6. 6

    Studies of electromagnetic interference of PET detector insert for simultaneous PET/MRI by Lee, Brian J., Olcott, Peter D., Key Jo Hong, Grant, Alexander M., Chen-Ming Chang, Levin, Craig S.

    “…We are developing a brain positron emission tomography (PET) system prototype with long optical cables to minimize mutual interference between our PET…”
    Get full text
    Conference Proceeding
  7. 7

    Readout Electronics and Data Acquisition of a Positron Emission Tomography Time-of-Flight Detector Module With Waveform Digitizer by Jung Yeol Yeom, Vinke, Ruud, Spanoudaki, Virginia C., Key Jo Hong, Levin, Craig S.

    Published in IEEE transactions on nuclear science (01-10-2013)
    “…A multi-element silicon photomultiplier (SiPM) based time-of-flight (ToF) detector module for positron emission tomography (PET) has been developed. The…”
    Get full text
    Journal Article
  8. 8

    A feasibility study of photosensor charge signal transmission to preamplifier using long cable for development of hybrid PET-MRI by Kang, Jihoon, Choi, Yong, Hong, Key Jo, Jung, Jin Ho, Hu, Wei, Huh, Yoon Suk, Lim, Hyunkeong, Kim, Byung-Tae

    Published in Medical physics (Lancaster) (01-11-2010)
    “…Purpose: A new positron emission tomography (PET) detector signal processing method, the charge signal transmission approach, is proposed for the development…”
    Get full text
    Journal Article
  9. 9

    Performance amelioration for small animal SPECT using optimized pinhole collimator and image correction technique by Song, Tae Yong, Choi, Yong, Jung, Jin Ho, Min, Byung Jun, Hong, Key Jo, Choe, Yearn Seong, Lee, Kyung-Han, Kim, Byung-Tae

    Published in IEEE transactions on nuclear science (01-10-2005)
    “…The aim of this study was to improve the performance of pinhole single photon emission computed tomography (SPECT) fabricated with a position sensitive…”
    Get full text
    Journal Article
  10. 10

    Trends of Data Path Topologies for Data Acquisition Systems in Positron Emission Tomography by Ealgoo Kim, Key Jo Hong, Jung Yeol Yeom, Olcott, Peter D., Levin, Craig S.

    Published in IEEE transactions on nuclear science (01-10-2013)
    “…In this paper, we describe current trends in data path topologies for Positron Emission Tomography (PET) data acquisition (DAQ) systems which is used to…”
    Get full text
    Journal Article
  11. 11

    A simple and improved digital timing method for positron emission tomography by Hu, Wei, Choi, Yong, Jo Hong, Key, Kang, Jihoon, Ho Jung, Jin, Suk Huh, Youn, Keong Lim, Hyun, Su Kim, Sang, Jun Min, Byung, Kim, Byung-Tae

    “…A simple and improved digital timing method was developed for positron emission tomography (PET). This method, the so-called ‘initial rise interpolation…”
    Get full text
    Journal Article
  12. 12
  13. 13

    Development of a position decoder circuit for PET consisting of GAPD arrays by Ho Jung, Jin, Choi, Yong, Jo Hong, Key, Hu, Wei, Hoon Kang, Ji, Jun Min, Byung, Han Shin, Seung, Keong Lim, Hyun, Suk Huh, Yoon, Kim, Eun-Jeong

    “…Use of channel reduction techniques that reduce the number of signals transmitted to a data acquisition (DAQ) module can lead to more efficient use of the DAQ…”
    Get full text
    Journal Article
  14. 14

    Therapy region monitoring based on PET using 478 keV single prompt gamma ray during BNCT: A Monte Carlo simulation study by Jung, Joo-Young, Lu, Bo, Yoon, Do-Kun, Hong, Key Jo, Jang, HongSeok, Liu, Chihray, Suh, Tae Suk

    Published in Physica medica (01-04-2016)
    “…Highlights • Tumor monitoring using prompt gamma ray during BNCT. • Acquisition of single prompt gamma image using insertable collimator from PET. • Prompt…”
    Get full text
    Journal Article
  15. 15

    Development of Filtering Methods for PET Signals Contaminated by RF Pulses for Combined PET-MRI by Huh, Yoonsuk, Choi, Yong, Hong, Key Jo, Hu, Wei, Kang, Jihoon, Jung, Jin Ho, Song, Myung Sung, Park, Hyun-wook, Kim, Byung-Tae

    Published in IEEE transactions on nuclear science (01-10-2013)
    “…This paper presents the development of filtering methods for positron emission tomography (PET) signals contaminated by radio frequency (RF) pulses for…”
    Get full text
    Journal Article
  16. 16

    Performance evaluation of a multi-pinhole collimator with vertical septa by Jun Min, Byung, Choi, Yong, Lee, Nam-Yong, Ho Jung, Jin, Jo Hong, Key, Kang, Jihoon, Hu, Wei, Bok Ahn, Young

    “…The authors have previously reported a simulation study on a novel multi-pinhole (MP) collimator that is able to provide improved angular sampling and an…”
    Get full text
    Journal Article
  17. 17

    FPGA-based time-to-digital converter for time-of-flight PET detector by Key Jo Hong, Ealgoo Kim, Jung Yeol Yeom, Olcott, Peter D., Levin, Craig S.

    “…We have developed a FPGA-based time-to-digital converter (TDC) that can be used for a TOF-PET block detector based on silicon photomultiplier (SiPM)…”
    Get full text
    Conference Proceeding
  18. 18

    A pulse width modulation readout method for densely packed solid state photodetectors by Bieniosek, Matthew F., Key Jo Hong, Levin, Craig S.

    “…The field of PET is moving toward systems comprising thousands of crystal elements coupled to thousands of semiconductor photodetector channels. Because of the…”
    Get full text
    Conference Proceeding
  19. 19

    A 16-channel FPGA-based time-to-digital converter for pulse width modulation circuitry for silicon photomultiplier readout by Key Jo Hong, Bieniosek, Matthew F., Kim, Ealgoo, Levin, Craig S.

    “…This work presents a 16-channel time-to-digital converter (TDC) implemented in a field programmable gate array (FPGA) that can be used for a positron emission…”
    Get full text
    Conference Proceeding
  20. 20

    Characterization of PET data acquisition system with compressed sensing detectors by Chen-Ming Chang, Olcott, Peter D., Key Jo Hong, Grant, Alexander M., Lee, Brian J., Ealgoo Kim, Levin, Craig S.

    “…We evaluated the timing performance of our data acquisition system (DAQ) with compressed sensing detectors we used in a PET insert for simultaneous PET/MR…”
    Get full text
    Conference Proceeding