Search Results - "Jafarzadehpur, Ebrahim"
-
1
Agreements' profile of Scheimpflug-based optical biometer with gold standard partial coherence interferometry
Published in International journal of ophthalmology (18-12-2023)“…To determine the agreement of ocular biometric indices including axial length, keratometric readings, anterior chamber depth, and horizontal corneal diameter…”
Get full text
Journal Article -
2
Multi-view deep learning for rigid gas permeable lens base curve fitting based on Pentacam images
Published in Medical & biological engineering & computing (01-07-2020)“…Many studies in the rigid gas permeable (RGP) lens fitting field have focused on providing the best fit for patients with irregular astigmatism, a challenging…”
Get full text
Journal Article -
3
The Repeatability of Axial Length Measurements Using a Scheimpflug-based System
Published in Journal of ophthalmic & vision research (01-10-2023)“…To assess the repeatability of Pentacam AXL as a Scheimpflug-based system or measuring axial length according to the age, sex, lens type, axial length value,…”
Get full text
Journal Article -
4
How long does the recovery of corneal sensitivity in different corneal regions take after LASEK?
Published in International journal of ophthalmology (18-12-2023)“…To determine the corneal sensitivity recovery period after laser-assisted sub-epithelial keratectomy (LASEK) refractive surgery and investigate the effects of…”
Get full text
Journal Article -
5
Early diagnosis of subclinical keratoconus by wavefront parameters using Scheimpflug, Placido and Hartmann–Shack based devices
Published in International ophthalmology (01-07-2020)“…Purpose To compare the accuracy of three devices (Pentacam, Sirius and OPD-Scan III) to differentiate subclinical keratoconus from normal corneas by wavefront…”
Get full text
Journal Article -
6
Keratoconus diagnosis using Corvis ST measured biomechanical parameters
Published in Iranian journal of ophthalmology (01-09-2017)“…To assess the diagnostic power of the Corneal Visualization Scheimpflug Technology (Corvis ST) provided corneal biomechanical parameters in keratoconic…”
Get full text
Journal Article -
7
Evaluation of visual evoked potential binocular summation after corneal refractive surgery
Published in Documenta ophthalmologica (01-04-2020)“…Purpose To explore whether visual evoked binocular summation is affected in eyes with refractive errors after refractive surgery. Methods Twenty participants…”
Get full text
Journal Article -
8
Diurnal Variations of Exophoria in Subjects With Normal Vision
Published in Function and disability journal (20-12-2022)“…Background and Objectives: We aimed to investigate the variation of heterophoria during a day in students with a normal visual system. Methods: This…”
Get full text
Journal Article -
9
Does Long-Term Night Shift Work Cause Dry Eye in Hospital Nurses?
Published in Journal of ophthalmic & vision research (01-10-2023)“…To determine the long-term effects of night shift work on dry eye in hospital nurses. Each participant was evaluated four times, including at the beginning of…”
Get full text
Journal Article -
10
Contrast Sensitivity Evaluation in a Population-Based Study in Shahroud, Iran
Published in Ophthalmology (Rochester, Minn.) (01-03-2012)“…Purpose To determine the normal range of contrast sensitivity and its determinants through a population-based study in Shahroud, in northern Iran. Design…”
Get full text
Journal Article -
11
Distribution of angle kappa measurements with Orbscan II in a population-based survey
Published in Journal of refractive surgery (1995) (01-12-2010)“…To determine the mean angle kappa and its determinants in the population of Tehran, Iran. In a cross-sectional survey with random cluster sampling, a total of…”
Get more information
Journal Article -
12
Comparison of anterior segment parameters of the eye between type 2 diabetic with and without diabetic retinopathy and non-diabetic
Published in International journal of ophthalmology (18-04-2023)“…To compare anterior segment parameters between two groups of type 2 diabetic with and without diabetic retinopathy (DR) and non-diabetic elderly subjects based…”
Get full text
Journal Article -
13
Color Vision in the Gas Station Workers of Isfahan City: A Quantitative Analysis With the Farnsworth D15 Color Test
Published in Function and disability journal (30-12-2021)“…Background and Objectives: The color vision evaluation of gas station workers in Isfahan City. Methods: This cross-sectional comparative study was performed on…”
Get full text
Journal Article -
14
An image processing approach for rigid gas-permeable lens base-curve identification
Published in Signal, image and video processing (01-07-2020)“…This research is aimed at accurate identification of base-curve in rigid gas-permeable (RGP) lens based on supervised image processing and classification of…”
Get full text
Journal Article -
15
Estimation of final cylindrical spectacle correction by Pentacam
Published in Function and disability journal (28-10-2020)“…Background and Objectives: Keratoconus is a non-inflammatory asymmetric corneal degenerative disease characterized by the steepening and distortion of the…”
Get full text
Journal Article -
16
Comparisons of Modulation Transform Function in 2 Monofocal Spherical Hydrophobic and Hydrophilic Intra Ocular Lenses
Published in Acta medica Iranica (13-11-2022)“…To compare Modulation Transform Function (MTF) between standard monofocal spherical hydrophobic acrylic Alcon SA60AT (Bausch and Lomb) and hydrophilic acrylic…”
Get full text
Journal Article -
17
Astigmatism in underserved rural areas: a population based study
Published in Ophthalmic & physiological optics (01-11-2016)“…Purpose Studying the prevalence of astigmatism and its related factors in underprivileged rural areas in Iran. Methods Using random cluster sampling, two rural…”
Get full text
Journal Article -
18
Low-contrast Pattern-reversal Visual Evoked Potential in Different Spatial Frequencies
Published in Journal of ophthalmic & vision research (01-07-2020)“…To evaluate the pattern-reversal visual evoked potential (PRVEP) in low-contrast, spatial frequencies in time, frequency, and time-frequency domains. PRVEP was…”
Get full text
Journal Article -
19
Contrast and spatial frequency modulation for diagnosis of amblyopia: An electrophysiological approach
Published in Iranian journal of ophthalmology (01-03-2019)“…To evaluate the diagnostic value of visual evoked potentials (VEPs) and to find out which test setting has the most sensitivity and specificity for amblyopia…”
Get full text
Journal Article -
20
Comparing Tear Film Stability Prolongation Evaluated by Javal–Schiotz Keratometer and Slitlamp
Published in Eye & contact lens (01-03-2015)“…OBJECTIVE:To innovatively compare the tear film stability assessed noninvasively by Javal–Schiotz keratometer (tear deformation time [TDT]) and invasively by…”
Get full text
Journal Article