Search Results - "JUKKALA, K"

  • Showing 1 - 14 results of 14
Refine Results
  1. 1
  2. 2

    Comparison of the fixation of subcapital femoral neck osteotomies with absorbable self-reinforced poly-L-lactide lag-screws or metallic screws in sheep by Jukkala-Partio, K, Laitinen, O, Partio, E K, Vasenius, J, Vainionpää, S, Pohjonen, T, Törmälä, P, Rokkanen, P

    Published in Journal of orthopaedic research (01-01-1997)
    “…Seven subcapital femoral osteotomies of adult sheep were each fixed with two absorbable self-reinforced poly-L-lactide lag-screws, and seven other osteotomies…”
    Get more information
    Journal Article
  3. 3

    Absorbable fixation of femoral head fractures. A prospective study of six cases by Jukkala-Partio, K, Partio, E K, Hirvensalo, E, Rokkanen, P

    “…Fracture of the femoral head associated with a traumatic dislocation of the hip is a rare but severe injury. The methods of the recommended treatment have…”
    Get more information
    Journal Article
  4. 4

    Treatment of subcapital femoral neck fractures with bioabsorbable or metallic screw fixation. A preliminary report by Jukkala-Partio, K, Partio, E K, Helevirta, P, Pohjonen, T, Törmälä, P, Rokkanen, P

    “…Cancellous bone fractures and arthrodeses have been treated successfully with bioabsorbable polyglycolide and poly-L-lactide implants. In this study…”
    Get more information
    Journal Article
  5. 5

    Biodegradation and strength retention of poly-L-lactide screws in vivo. An experimental long-term study in sheep by Jukkala-Partio, K, Pohjonen, T, Laitinen, O, Partio, E K, Vasenius, J, Toivonen, T, Kinnunen, J, Törmälä, P, Rokkanen, P

    “…Poly-L-lactide implants have gained popularity in the fixation of fractures and osteotomies in the past decade. The aim of the present experimental long-term…”
    Get more information
    Journal Article
  6. 6

    Treatment of periprosthetic fractures in association with total hip arthroplasty--a retrospective comparison between revision stem and plate fixation by Jukkala-Partio, K, Partio, E K, Solovieva, S, Paavilainen, T, Hirvensalo, E, Alho, A

    “…In periprosthetic fracture associated with hip arthroplasty, no consensus exists about the use of plate fixation or revision stem except for cases where the…”
    Get more information
    Journal Article
  7. 7

    Adaptation of the rat kidney to altered water intake and urine concentration by BANKIR, L, FISCHER, C, FISCHER, S, JUKKALA, K, SPECHT, H.-C, KRIZ, W

    Published in Pflügers Archiv (01-07-1988)
    “…Previous experiments in Brattleboro rats with hereditary diabetes insipidus revealed that absence of ADH led to several alterations in kidney anatomy, which…”
    Get full text
    Journal Article
  8. 8

    Healing of subcapital femoral osteotomies fixed with self-reinforced poly-L-lactide screws: an experimental long-term study in sheep by JUKKALA-PARTIO, Kirsi, LAITINEN, Outi, VASENIUS, Jarkko, PARTIO, Esa K, TOIVONEN, Terttu, TERVAHARTIALA, Pekka, KINNUNEN, Jaakko, ROKKANEN, Pentti

    Published in Archives of orthopaedic and trauma surgery (01-07-2002)
    “…Subcapital femoral osteotomies of ten young adult sheep were fixed with two bioabsorbable, self-reinforced, poly- L-lactide (SR-PLLA) lag screws of 4.5 mm in…”
    Get full text
    Journal Article
  9. 9
  10. 10
  11. 11

    Causes of the clinical tissue response to polyglycolide and polylactide implants with an emphasis on the knee by TUOMPO, Pertti, PARTIO, Esa K, PÄTIÄLÄ, Hannu, JUKKALA-PARTIO, Kirsi, HIRVENSALO, Eero, ROKKANEN, Pentti

    Published in Archives of orthopaedic and trauma surgery (01-05-2001)
    “…The causes of a clinical tissue response to self-reinforced polyglycolide (SR-PGA) and self-reinforced polylactide (SR-PLLA) implants were studied in the first…”
    Get full text
    Journal Article
  12. 12

    Strength of the fixation of patellar tendon bone grafts using a totally absorbable self-reinforced poly-L-lactide expansion plug and screw. An experimental study in a bovine cadaver by Tuompo, P, Partio, E K, Jukkala-Partio, K, Pohjonen, T, Helevirta, P, Rokkanen, P

    Published in Arthroscopy (01-08-1996)
    “…In a bovine cadaver study, bone-tendon-bone graft fixation strength with different graft geometry and fixation devices was measured to evaluate the fixation…”
    Get more information
    Journal Article
  13. 13
  14. 14

    Talocrural arthrodesis with absorbable screws, 12 cases followed for 1 year by Partio, E K, Hirvensalo, E, Partio, E, Pelttari, S, Jukkala-Partio, K, Böstman, O, Hänninen, A, Törmälä, P, Rokkanen, P

    Published in Acta orthopaedica Scandinavica (01-04-1992)
    “…In 11 patients, 12 arthrodeses of the ankle joint were performed by using absorbable self-reinforced poly-l-lactide (SR-PLLA) or polyglycolide (SR-PGA) screws…”
    Get more information
    Journal Article