Search Results - "J. Heselius S."

Refine Results
  1. 1

    Elemental analyses of pine bark and wood in an environmental study by Saarela, K.-E., Harju, L., Rajander, J., Lill, J.-O., Heselius, S.-J., Lindroos, A., Mattsson, K.

    Published in The Science of the total environment (01-05-2005)
    “…Bark and wood samples were taken from the same individuals of Scots pine ( Pinus sylvestris L.) from a polluted area close to a Cu–Ni smelter in Harjavalta and…”
    Get full text
    Journal Article
  2. 2

    Temporal changes in elemental composition in decomposing filamentous algae (Cladophora glomerata and Pilayella littoralis) determined with PIXE and PIGE by Lill, J.-O., Salovius-Laurén, S., Harju, L., Rajander, J., Saarela, K.-E., Lindroos, A., Heselius, S.-J.

    Published in The Science of the total environment (01-01-2012)
    “…Particle-induced X-ray emission and particle-induced gamma-ray emission spectrometry were successfully applied in a study of the elemental composition of…”
    Get full text
    Journal Article
  3. 3

    Strontium and zinc concentrations in otoliths of common fish species in the northern Baltic Sea by Lill, J.-O., Himberg, M., Harju, L., Ek, P., Lindroos, A., Wiklund, T., Gunnelius, K., Smått, J.-H., Heselius, S.-J., Hägerstrand, H.

    “…Otoliths of perch (Perca fluviatilis), pike (Esox lucius) and European whitefish (Coregonus lavaretus) caught at different locations in the northern Baltic Sea…”
    Get full text
    Journal Article
  4. 4

    Environmental monitoring of trace elements in bark of Scots pine by thick-target PIXE by Harju, L., Saarela, K.-E., Rajander, J., Lill, J.-O., Lindroos, A., Heselius, S.-J.

    “…Bark samples were taken from Scots pines ( Pinus sylvestris L.) from a polluted area near a metal plant and from a relatively non-polluted site. Thick-target…”
    Get full text
    Journal Article
  5. 5

    External-beam PIXE characterization of volcanic material used in ancient Roman mortars by Sonck-Koota, P., Lindroos, A., Lill, J.-O., Rajander, J., Viitanen, E.-M., Marra, F., Pehkonen, M.H., Suksi, J., Heselius, S.-J.

    “…Volcanic deposits from two volcanic districts, Monti Sabatini (MSVD) and Colli Albani (CAVD), NW and SE of Rome, were analyzed using the particle-induced X-ray…”
    Get full text
    Journal Article
  6. 6

    Thick-target PIGE analysis of plant materials preconcentrated by dry ashing by Saarela, K.-E., Harju, L., Lill, J.-O., Rajander, J., Lindroos, A., Heselius, S.-J.

    Published in Talanta (Oxford) (03-04-2000)
    “…Plant materials were dry ashed at 550°C and analysed using particle-induced prompt gamma-ray emission (PIGE). The analyses were performed with an external beam…”
    Get full text
    Journal Article
  7. 7

    Increased sensitivity in thick-target particle induced X-ray emission analyses using dry ashing for preconcentration by Lill, J.-O., Harju, L., Saarela, K.-E., Lindroos, A., Heselius, S.-J.

    Published in Analytica chimica acta (04-01-1999)
    “…The sensitivity in thick-target particle induced X-ray emission (PIXE) analyses of biological materials can be enhanced by dry ashing. The gain depends mainly…”
    Get full text
    Journal Article
  8. 8

    Excitation functions for proton-induced reactions on natural hafnium: Production of (1(7(7)Lu for medical use by Siiskonen, T, Huikari, J, Haavisto, T, Bergman, J, Heselius, S J, Lill, J O, Lonnroth, T, Perajarvi, K, Vartti, V P

    “…There is an increasing interest in using radioisotopes of rare earth elements for internal radiotherapy and for imaging in nuclear medicine. (1(7(7)Lu is one…”
    Get full text
    Journal Article
  9. 9

    Excitation functions of proton-induced reactions in (nat)Cu in the energy range 7-17 MeV by Siiskonen, T, Huikari, J, Haavisto, T, Bergman, J, Heselius, S-J, Lill, J-O, Lönnroth, T, Peräjärvi, K

    Published in Applied radiation and isotopes (01-11-2009)
    “…Elemental production cross sections were measured for (p,x) reactions on natural Cu targets, leading to the formation of (62,63,65)Zn. These reactions are…”
    Get full text
    Journal Article
  10. 10

    Excitation functions for proton-induced reactions on natural hafnium: Production of 177Lu for medical use by Siiskonen, T., Huikari, J., Haavisto, T., Bergman, J., Heselius, S.-J., Lill, J.-O., Lönnroth, T., Peräjärvi, K., Vartti, V.-P.

    “…There is an increasing interest in using radioisotopes of rare earth elements for internal radiotherapy and for imaging in nuclear medicine. 177Lu is one of…”
    Get full text
    Journal Article
  11. 11
  12. 12

    Static and dynamic effects in gas targets used for medical isotope production by Tárkányi, F, Takács, S, Heselius, S.-J, Solin, O, Bergman, J

    “…The penetration of light charged particles in gas targets has been studied. Light emitted by atoms was recorded by using video and film techniques and the…”
    Get full text
    Journal Article
  13. 13

    Study of seasonal variations of trace-element concentrations within tree rings by thick-target PIXE analyses by Harju, L., Lill, J-O., Saarela, K-E., Heselius, S-J., Hernberg, F.J., Lindroos, A.

    “…Thick-target PIXE has been used for the quantitative determination of trace elements in annual growth rings of different tree species. A scanning device was…”
    Get full text
    Journal Article
  14. 14

    Monitoring of chromium, copper and arsenic in contaminated soils using thick-target PIXE by Rajander, J, Harju, L, Lill, J.-O, Saarela, K.-E, Lindroos, A, Heselius, S.-J

    “…Soil contamination by toxic metal ions is one of the most serious environmental problems today. In this work soil samples from an area where a wood…”
    Get full text
    Journal Article
  15. 15

    Thick-target Pixe analysis of chromium, copper and arsenic impregnated lumber by Saarela, K-E, Harju, L, Lill, J-O, Rajander, J, Lindroos, A, Heselius, S-J

    “…Chromium, copper and arsenic (CCA) have for decades been used for wood preservation. Of these elements especially arsenic is very toxic. As CCA impregnated…”
    Get full text
    Journal Article
  16. 16

    Multi-Element Analysis of Dry-Ashed Honey Samples by Thick-Target PIXE by Saarelaa, K-E., Lill, J-O., Harju, L., Lindroos, A., Heselius, S-J.

    “…Honey samples were dry ashed at 550°C and the ashes were directly analysed with the Thick-Target Particle Induced X-ray Emission (TTPIXE) technique. The…”
    Get full text
    Journal Article
  17. 17

    Excitation functions of 3He- and α-particle induced nuclear reactions on natSb for production of medically relevant 123I and 124I radioisotopes by Tárkányi, F., Takács, S., Király, B., Szelecsényi, F., Andó, L., Bergman, J., Heselius, S.-J., Solin, O., Hermanne, A., Shubin, Yu.N., Ignatyuk, A.V.

    Published in Applied radiation and isotopes (01-06-2009)
    “…Excitation functions were measured using the stacked foil irradiation technique from threshold energies to 28 MeV for 3He- and to 21 MeV for α-particle induced…”
    Get full text
    Journal Article
  18. 18

    Preconcentration of trace elements in biological materials by dry ashing for TTPIXE analysis A study of matrix effects by Saarela, K-E., Lill, J-O., Hernberg, F.J., Harju, L., Lindroos, A., Heselius, S-J.

    “…Trace elements in biological materials were preconcentrated by dry ashing at 550°C in order to improve the detection limits for thick-target PIXE analyses. The…”
    Get full text
    Journal Article
  19. 19

    Investigation of the charged particle nuclear reactions on natural boron for the purposes of the thin layer activation (TLA) by Ditrói, F., Takács, S., Tárkányi, F., Fenyvesi, A., Bergman, J., Heselius, S.-J., Solin, O.

    “…Boron of natural composition was investigated in the form of NiBSi metallic-glass foil to determine the cross-section functions of the natB(p,x) 7Be and the…”
    Get full text
    Journal Article
  20. 20

    New experimental data on excitation functions for practical applications of alpha induced nuclear reactions on Ta up to 30 MeV by Tárkányi, F, Takács, S, Hermanne, A, Ditrói, F, Andó, L, Heselius, S.-J, Bergman, J

    “…Excitation functions of the natTa(α, xn) 184m,184g,183,182m,182mg,181Re nuclear reactions have been investigated with stacked foil method up to 30 MeV to…”
    Get full text
    Journal Article