Search Results - "Iwanczyk, Jan S"

Refine Results
  1. 1

    Vision 20/20: Single photon counting x-ray detectors in medical imaging by Taguchi, Katsuyuki, Iwanczyk, Jan S.

    Published in Medical physics (Lancaster) (01-10-2013)
    “…Photon counting detectors (PCDs) with energy discrimination capabilities have been developed for medical x-ray computed tomography (CT) and x-ray (XR) imaging…”
    Get full text
    Journal Article
  2. 2

    An analytical model of the effects of pulse pileup on the energy spectrum recorded by energy resolved photon counting x-ray detectors by Taguchi, Katsuyuki, Frey, Eric C., Wang, Xiaolan, Iwanczyk, Jan S., Barber, William C.

    Published in Medical physics (Lancaster) (01-08-2010)
    “…Purpose: Recently, novel CdTe photon counting x-ray detectors (PCXDs) with energy discrimination capabilities have been developed. When such detectors are…”
    Get full text
    Journal Article
  3. 3

    A cascaded model of spectral distortions due to spectral response effects and pulse pileup effects in a photon-counting x-ray detector for CT by Cammin, Jochen, Xu, Jennifer, Barber, William C., Iwanczyk, Jan S., Hartsough, Neal E., Taguchi, Katsuyuki

    Published in Medical physics (Lancaster) (01-04-2014)
    “…Purpose: Energy discriminating, photon-counting detectors (PCDs) are an emerging technology for computed tomography (CT) with various potential benefits for…”
    Get full text
    Journal Article
  4. 4

    Modeling the performance of a photon counting x-ray detector for CT: Energy response and pulse pileup effects by Taguchi, Katsuyuki, Zhang, Mengxi, Frey, Eric C., Wang, Xiaolan, Iwanczyk, Jan S., Nygard, Einar, Hartsough, Neal E., Tsui, Benjamin M. W., Barber, William C.

    Published in Medical physics (Lancaster) (01-02-2011)
    “…Purpose: Recently, photon counting x-ray detectors (PCXDs) with energy discrimination capabilities have been developed for potential use in clinical computed…”
    Get full text
    Journal Article
  5. 5

    Photon Counting Energy Dispersive Detector Arrays for X-ray Imaging by Iwanczyk, J.S., Nygard, E., Meirav, O., Arenson, J., Barber, W.C., Hartsough, N.E., Malakhov, N., Wessel, J.C.

    Published in IEEE transactions on nuclear science (01-06-2009)
    “…The development of an innovative detector technology for photon-counting in X-ray imaging is reported. This new generation of detectors, based on pixellated…”
    Get full text
    Journal Article
  6. 6

    Assessment of multi‐energy inter‐pixel coincidence counters for photon‐counting detectors at the presence of charge sharing and pulse pileup: A simulation study by Taguchi, Katsuyuki, Iwanczyk, Jan S.

    Published in Medical physics (Lancaster) (01-09-2021)
    “…Purpose Spectral distortion due to charge sharing (CS) and pulse pileup (PP) in photon‐counting detectors (PCDs) degrades the quality of PCD data. We recently…”
    Get full text
    Journal Article
  7. 7

    Quantitative fluorescence tomography using a combined tri-modality FT/DOT/XCT system by Lin, Yuting, Barber, William C, Iwanczyk, Jan S, Roeck, Werner, Nalcioglu, Orhan, Gulsen, Gultekin

    Published in Optics express (12-04-2010)
    “…In this work, a first-of-its-kind fully integrated tri-modality system that combines fluorescence, diffuse optical and x-ray tomography (FT/DOT/XCT) into the…”
    Get full text
    Journal Article
  8. 8

    Polycrystalline Mercuric Iodide Films on CMOS Readout Arrays by Hartsough, N.E., Iwanczyk, J.S., Nygard, E., Malakhov, N., Barber, W.C., Gandhi, T.

    Published in IEEE transactions on nuclear science (01-08-2009)
    “…We have created high-resolution x-ray imaging devices using polycrystalline mercuric iodide (HgI 2 ) films grown directly onto CMOS readout chips using a…”
    Get full text
    Journal Article
  9. 9

    Characterization of energy response for photon‐counting detectors using x‐ray fluorescence by Ding, Huanjun, Cho, Hyo‐Min, Barber, William C., Iwanczyk, Jan S., Molloi, Sabee

    Published in Medical physics (Lancaster) (01-12-2014)
    “…Purpose: To investigate the feasibility of characterizing a Si strip photon‐counting detector using x‐ray fluorescence. Methods: X‐ray fluorescence was…”
    Get full text
    Journal Article
  10. 10

    Characteristic performance evaluation of a photon counting Si strip detector for low dose spectral breast CT imaging by Cho, Hyo‐Min, Barber, William C., Ding, Huanjun, Iwanczyk, Jan S., Molloi, Sabee

    Published in Medical physics (Lancaster) (01-09-2014)
    “…Purpose: The possible clinical applications which can be performed using a newly developed detector depend on the detectorˈs characteristic performance in a…”
    Get full text
    Journal Article
  11. 11

    Microcalcification detectability using a bench‐top prototype photon‐counting breast CT based on a Si strip detector by Cho, Hyo‐Min, Ding, Huanjun, Barber, William C., Iwanczyk, Jan S., Molloi, Sabee

    Published in Medical physics (Lancaster) (01-07-2015)
    “…Purpose: To investigate the feasibility of detecting breast microcalcification (μCa) with a dedicated breast computed tomography (CT) system based on…”
    Get full text
    Journal Article
  12. 12

    Quantitative fluorescence tomography using a trimodality system: in vivo validation by Lin, Yuting, Barber, William C, Iwanczyk, Jan S, Roeck, Werner W, Nalcioglu, Orhan, Gulsen, Gultekin

    Published in Journal of biomedical optics (01-07-2010)
    “…A fully integrated trimodality fluorescence, diffuse optical, and x-ray computed tomography (FT/DOT/XCT) system for small animal imaging is reported in this…”
    Get full text
    Journal Article
  13. 13

    Intraoperative gamma imaging of axillary sentinel lymph nodes in breast cancer patients by Aarsvod, John N., Greene, Carmen M., Mintzer, Robert A., Grant, Sandra F., Styblo, Toncred M., Alazraki, Naomi P., Patt, Bradley E., Caravaglia, Gina M., Li, Joshua, Iwanczyk, Jan S.

    Published in Physica medica (2006)
    “…Sentinel lymph node (SLN) biopsy is now standard practice in the management of many breast cancer patients. Localization protocols vary in complexity and rates…”
    Get full text
    Journal Article
  14. 14
  15. 15

    Intraoperative probes and imaging probes by Hoffman, E J, Tornai, M P, Janecek, M, Patt, B E, Iwanczyk, J S

    Published in European journal of nuclear medicine (01-08-1999)
    “…Intraoperative probes have been employed to assist in the detection and removal of tumors for more than 50 years. For a period of about 40 years, essentially…”
    Get full text
    Journal Article
  16. 16
  17. 17

    A novel silicon array designed for intraoperative charged particle imaging by Tornai, Martin P., Patt, Bradley E., Iwanczyk, Jan S., Tull, Carolyn R., MacDonald, Lawrence R., Hoffman, Edward J.

    Published in Medical physics (Lancaster) (01-11-2002)
    “…A novel Si-PIN imaging array is under investigation for a charged particle (beta, positron, or alpha) sensitive intraoperative camera to be used for (residual)…”
    Get full text
    Journal Article
  18. 18
  19. 19

    Intravascular probe for detection of vulnerable plaque by Janecek, Martin, Patt, Bradley E, Iwanczyk, Jan S, MacDonald, Lawrence, Yamaguchi, Yuko, William Strauss, H, Tsugita, Ross, Ghazarossian, Vartan, Hoffman, Edward J

    Published in Molecular imaging and biology (01-05-2004)
    “…Coronary angiography defines geometry of lumen of artery. However, perhaps 70% of heart attacks occur when minimally obstructive thin capped fibroatheroma…”
    Get more information