    Optical and pressure diagnostics of 4-MV water switches in the Z-20 test Facility by Woodworth, J.R., Lehr, J.M., Elizondo-Decanini, J., Miller, P.A., Wakeland, P., Kincy, M., Garde, J., Aragon, B., Fowler, W., Mowrer, G., Maenchen, J.E., Sarkisov, G.S., Corley, J., Hodge, K., Drennan, S., Guthrie, D., Navarro, M., Johnson, D.L., Ives, H.C., Slattery, M.J., Muirhead, D.A.

    Published in IEEE transactions on plasma science (01-10-2004)
    “…We are studying the behavior of self-breaking, high-voltage water switches for the Z refurbishment project. In Z-20, three or four water switches in parallel…”
    Get full text
    Journal Article Conference Proceeding
  2. 2
  3. 3
  4. 4

    High-voltage hold-off of large surface area metal electrodes with dielectric surface layers by Johnson, D.J., Ives, H.C., Savage, M.E., Stygar, W.A.

    “…Aluminum and stainless steel electrodes with dielectric surface layers have been tested for the avoidance of electron emission and plasma induced arcs that…”
    Get full text
    Conference Proceeding
  5. 5

    A pulse power modulator system for commercial high power ion beam surface treatment applications by Barrett, D.M., Cockreham, B.D., Dragt, A.J., White, F.E., Neau, E.L., Reed, K.W., Ives, H.C.

    “…The ion beam surface treatment (IBEST/sup TM/) process utilizes high energy pulsed ion beams to deposit energy onto the surface of a material allowing near…”
    Get full text
    Conference Proceeding
  6. 6

    Effect of self-magnetic field on large pulsed insulators operated at 4 megavolts and 5 megaamperes by Savage, M.E., Stygar, W.A., Elizondo, J.M., Ives, H.C., Shoup, W., Struve, K.W., McDaniel, D.H.

    “…Experiments on a large, high voltage pulsed insulator will be described. The goal was investigation of the effect of the self-magnetic field associated with…”
    Get full text
    Conference Proceeding
  7. 7

    PBFA-Z vacuum section design using TLCODE simulations by Corcoran, P.A., Douglas, J.W., Smith, I.D., Spence, P.W., Stygar, W.A., Struve, K.W., Martin, T.H., Spielman, R.B., Ives, H.C.

    “…Circuit code simulations were used to predict the performance of and to assess design trade-offs for the vacuum section of PBFA-Z. PBFA-Z was designed to drive…”
    Get full text
    Conference Proceeding
  8. 8
  9. 9

    Engineering design of the Z magnetically-insulated transmission lines and insulator stack by Ives, H.C., van de Valde, D.M., Long, F.W., Smith, J.W., Spielman, R.B., Stygar, W.A., Wavrik, R.W., Shoup, R.W.

    “…A 3.3 m diameter cylindrical insulator stack and a set of 3 m diameter conical magnetically-insulated transmission lines (MITLs) were built for the Z…”
    Get full text
    Conference Proceeding
  10. 10
  11. 11
  12. 12

    Water-line design and performance of Z [pulsed power supply] by Garcia, R.J., Ives, H.C., Struve, K.W., Spielman, R.B., Martin, T.H., Horry, M.L., Waverick, R., Jaramillo, T.F.

    “…A new set of bi-plate transmission lines have been designed and installed in the water-section of PBFA-lI for the Z-pinch experiments. Thirty-six aluminum…”