Search Results - "Ives, H C"

Refine Results
  1. 1

    Architecture of petawatt-class z -pinch accelerators by Stygar, W. A., Cuneo, M. E., Headley, D. I., Ives, H. C., Leeper, R. J., Mazarakis, M. G., Olson, C. L., Porter, J. L., Wagoner, T. C., Woodworth, J. R.

    “…We have developed an accelerator architecture that can serve as the basis of the design of petawatt-class z-pinch drivers. The architecture has been applied to…”
    Get full text
    Journal Article
  2. 2
  3. 3

    Dielectric-breakdown tests of water at 6 MV by Stygar, W. A., Savage, M. E., Wagoner, T. C., Bennett, L. F., Corley, J. P., Donovan, G. L., Fehl, D. L., Ives, H. C., LeChien, K. R, Leifeste, G. T., Long, F. W., McKee, R. G., Mills, J. A., Moore, J. K., Ramirez, J. J., Stoltzfus, B. S., Struve, K. W., Woodworth, J. R.

    “…We have conducted dielectric-breakdown tests on water subject to a single unipolar pulse. The peak voltages used for the tests range from 5.8 to 6.8 MV; the…”
    Get full text
    Journal Article
  4. 4

    Analytic model of a magnetically insulated transmission line with collisional flow electrons by Stygar, W. A., Wagoner, T. C., Ives, H. C., Corcoran, P. A., Cuneo, M. E., Douglas, J. W., Gilliland, T. L., Mazarakis, M. G., Ramirez, J. J., Seamen, J. F., Seidel, D. B., Spielman, R. B.

    “…We have developed a relativistic-fluid model of the flow-electron plasma in a steady-state one-dimensional magnetically insulated transmission line (MITL). The…”
    Get full text
    Journal Article
  5. 5
  6. 6

    Optical and pressure diagnostics of 4-MV water switches in the Z-20 test Facility by Woodworth, J.R., Lehr, J.M., Elizondo-Decanini, J., Miller, P.A., Wakeland, P., Kincy, M., Garde, J., Aragon, B., Fowler, W., Mowrer, G., Maenchen, J.E., Sarkisov, G.S., Corley, J., Hodge, K., Drennan, S., Guthrie, D., Navarro, M., Johnson, D.L., Ives, H.C., Slattery, M.J., Muirhead, D.A.

    Published in IEEE transactions on plasma science (01-10-2004)
    “…We are studying the behavior of self-breaking, high-voltage water switches for the Z refurbishment project. In Z-20, three or four water switches in parallel…”
    Get full text
    Journal Article Conference Proceeding
  7. 7
  8. 8
  9. 9
  10. 10
  11. 11
  12. 12
  13. 13
  14. 14
  15. 15
  16. 16

    High-voltage hold-off of large surface area metal electrodes with dielectric surface layers by Johnson, D.J., Ives, H.C., Savage, M.E., Stygar, W.A.

    “…Aluminum and stainless steel electrodes with dielectric surface layers have been tested for the avoidance of electron emission and plasma induced arcs that…”
    Get full text
    Conference Proceeding
  17. 17

    Effect of self-magnetic field on large pulsed insulators operated at 4 megavolts and 5 megaamperes by Savage, M.E., Stygar, W.A., Elizondo, J.M., Ives, H.C., Shoup, W., Struve, K.W., McDaniel, D.H.

    “…Experiments on a large, high voltage pulsed insulator will be described. The goal was investigation of the effect of the self-magnetic field associated with…”
    Get full text
    Conference Proceeding
  18. 18

    PBFA-Z vacuum section design using TLCODE simulations by Corcoran, P.A., Douglas, J.W., Smith, I.D., Spence, P.W., Stygar, W.A., Struve, K.W., Martin, T.H., Spielman, R.B., Ives, H.C.

    “…Circuit code simulations were used to predict the performance of and to assess design trade-offs for the vacuum section of PBFA-Z. PBFA-Z was designed to drive…”
    Get full text
    Conference Proceeding
  19. 19

    Engineering design of the Z magnetically-insulated transmission lines and insulator stack by Ives, H.C., van de Valde, D.M., Long, F.W., Smith, J.W., Spielman, R.B., Stygar, W.A., Wavrik, R.W., Shoup, R.W.

    “…A 3.3 m diameter cylindrical insulator stack and a set of 3 m diameter conical magnetically-insulated transmission lines (MITLs) were built for the Z…”
    Get full text
    Conference Proceeding
  20. 20