Search Results - "Introini, M.V."
-
1
CYSP: A new cylindrical directional neutron spectrometer. Conceptual design
Published in Radiation measurements (01-11-2015)“…This communication describes in detail the design of a new cylindrical neutron spectrometer (CYSP) embedding 7 active thermal neutron detectors in a moderating…”
Get full text
Journal Article -
2
-
3
Study of a silicon telescope for solid state microdosimetry: Preliminary measurements at the therapeutic proton beam line of CATANA
Published in Radiation measurements (01-12-2010)“…A monolithic silicon device consisting of a matrix of micrometric cylindrical diodes (about 2 μm in thickness and 9 μm in diameter) coupled to a residual…”
Get full text
Journal Article Conference Proceeding -
4
A novel avalanche-confinement TEPC for microdosimetry at nanometric level
Published in EPJ Web of Conferences (01-01-2017)“…The tissue equivalent proportional counter (TEPC) is the most accurate device for measuring the microdosimetric properties of a particle beam, showing to…”
Get full text
Journal Article Conference Proceeding -
5
Performance of a proton irradiation chamber
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (01-02-2012)“…A Proton Irradiation Chamber aiming to perform radiation tests of electronic components was developed. The precision on the measurement of the ion currents was…”
Get full text
Journal Article -
6
Target thickness dependence of the Be(p,xn) neutron energy spectrum
Published in EPJ Web of conferences (01-01-2014)“…We report on the current status of the analysis of an experiment performed at The Svedberg Laboratory, with the aim of investigating the produced neutron field…”
Get full text
Journal Article -
7
A miniaturized alpha spectrometer for the calibration of an avalanche-confinement TEPC
Published in Radiation measurements (01-11-2017)Get full text
Journal Article -
8
EP-1798: Online neutron fluence measurements in phantom for second cancer risk estimation in radiotherapy
Published in Radiotherapy and oncology (2014)Get full text
Journal Article -
9
-
10
First test of SP2: A novel active neutron spectrometer condensing the functionality of Bonner spheres in a single moderator
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (11-12-2014)“…The NESCOFI@BTF (2011–2013) international collaboration was established to develop realtime neutron spectrometers to simultaneously cover all energy components…”
Get full text
Journal Article -
11
Experimental characterization of semiconductor-based thermal neutron detectors
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (21-04-2015)“…In the framework of NESCOFI@BTF and NEURAPID projects, active thermal neutron detectors were manufactured by depositing appropriate thickness of 6LiF on…”
Get full text
Journal Article -
12
A telescope detection system for direct and high resolution spectrometry of intense neutron fields
Published in Radiation measurements (01-02-2016)“…A high energy- and spatial-resolution telescope detector was designed and constructed for neutron spectrometry of intense neutron fields. The detector is…”
Get full text
Journal Article -
13
Experimental test of a newly developed single-moderator, multi-detector, directional neutron spectrometer in reference monochromatic fields from 144keV to 16.5MeV
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (11-05-2015)“…A new directional neutron spectrometer called CYSP (CYlindrical SPectrometer) was developed within the NESCOFI@BTF (2011–2013) collaboration. The device,…”
Get full text
Journal Article -
14
Designing an extended energy range single-sphere multi-detector neutron spectrometer
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (11-06-2012)“…This communication describes the design specifications for a neutron spectrometer consisting of 31 thermal neutron detectors, namely Dysprosium activation…”
Get full text
Journal Article -
15
300. Computed tomography use in a large italian region: Trend analysis 2004–2014 of emergency and outpatient CT examinations in children and adults
Published in Physica medica (01-12-2018)“…To analyse Computed Tomography (CT) use in recent years in a high population density area in Italy (approximately 10 million inhabitants, including 1 million…”
Get full text
Journal Article -
16
Thermal neutron imaging through XRQA2 GAFCHROMIC films coupled with a cadmium radiator
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (21-10-2015)“…A simple and inexpensive method to perform passive thermal neutron imaging on large areas was developed on the basis of XRQA2 GAFCHROMIC films, commonly…”
Get full text
Journal Article -
17
Response of a silicon telescope microdosimeter to 400 AMeV carbon ions
Published in Radiation measurements (01-12-2014)“…A monolithic silicon telescope consisting of a surface ΔE detector 2 μm in thickness coupled to an E detector about 500 μm in thickness made out of a single…”
Get full text
Journal Article Conference Proceeding -
18
ETHERNES: A new design of radionuclide source-based thermal neutron facility with large homogeneity area
Published in Applied radiation and isotopes (01-01-2016)“…A new thermal neutron irradiation facility based on an 241Am–Be source embedded in a polyethylene moderator has been designed, and is called ETHERNES (Extended…”
Get full text
Journal Article -
19
Beam characterization of a monolithic ΔE/E silicon device
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (11-04-2015)“…A full characterization of a ΔE/E monolithic silicon detector especially developed for microdosimetry was performed using monochromatic beams of α-particles…”
Get full text
Journal Article -
20
TWO NEW SINGLE-EXPOSURE, MULTI-DETECTOR NEUTRON SPECTROMETERS FOR RADIATION PROTECTION APPLICATIONS IN WORKPLACE MONITORING
Published in Radiation protection dosimetry (01-04-2017)“…This communication describes two new instruments, based on multiple active thermal neutron detectors arranged within a single moderator, that permit to unfold…”
Get full text
Journal Article