Search Results - "Ilango, G. Saravana"
-
1
A Method to Detect Photovoltaic Array Faults and Partial Shading in PV Systems
Published in IEEE journal of photovoltaics (01-09-2016)“…Abnormal conditions such as faults and partial shading lead to a reduction in the maximum available power from a photovoltaic (PV) array. Thus, it is necessary…”
Get full text
Journal Article -
2
Maximum Power from PV Arrays Using a Fixed Configuration Under Different Shading Conditions
Published in IEEE journal of photovoltaics (01-03-2014)“…A major challenge in photovoltaic (PV) systems is making them energy efficient. One of the major factors that contribute to the reduction of PV power is…”
Get full text
Journal Article -
3
An Improved Angular Stator Flux Frequency Computation Method for Robust MPPT Operation of DFIG Under Unbalanced Grid Voltage
Published in IEEE transactions on industry applications (01-01-2023)“…Maximum power extraction and constant power generation in a smooth and uninterrupted manner are challenging control tasks for the robust operation of DFIG…”
Get full text
Journal Article -
4
A unique control strategy to improve the life cycle of the battery and to reduce the thermal runaway for electric vehicle applications
Published in Journal of thermal analysis and calorimetry (01-09-2020)“…This paper presents a unique thermal control strategy to improve the ageing of the battery and to maintain the internal temperature of the battery within the…”
Get full text
Journal Article -
5
Design and implementation of a current controlled grid connected inverter for thermoelectric generator sources
Published in Sadhana (Bangalore) (01-12-2020)“…This paper presents the digital implementation of a current controlled grid connected inverter for Thermoelectric Generator (TEG) sources. Considering the…”
Get full text
Journal Article -
6
An Effective Reference Generation Scheme for DFIG With Unbalanced Grid Voltage
Published in IEEE transactions on sustainable energy (01-07-2014)“…This paper presents a reference current generation scheme for improved dynamic performance of a doubly fed induction generator (DFIG) subjected to unbalanced…”
Get full text
Journal Article -
7
A stator voltage switching strategy for efficient low speed operation of DFIG using fractional rated converters
Published in Renewable energy (01-09-2015)“…This paper presents a scheme for extending low speed operation of a wind driven Doubly Fed Induction Generator (DFIG) with limited rating converters (30%). In…”
Get full text
Journal Article -
8
Optimal Su-Do-Ku based interconnection scheme for increased power output from PV array under partial shading conditions
Published in Frontiers in Energy (01-06-2015)“…Partial shading is a common phenomenon in PV arrays. They drastically reduce the power output because of mismatch losses, which are reliant on the shape of the…”
Get full text
Journal Article -
9
A three phase PLL with a dynamic feed forward frequency estimator for synchronization of grid connected converters under wide frequency variations
Published in International journal of electrical power & energy systems (01-10-2012)“…► SRF PLL with dynamic feed forward frequency. ► The hybrid structure is simple to implement. ► Can be extended to any existing PLL technique with constant…”
Get full text
Journal Article -
10
Single-stage sine-wave inverter for an autonomous operation of solar photovoltaic energy conversion system
Published in Renewable energy (2010)“…This paper proposes a high performance single-stage inverter topology for the autonomous operation of a solar photovoltaic system. The proposed configuration…”
Get full text
Journal Article -
11
An active islanding detection technique for current controlled inverter
Published in Renewable energy (01-03-2013)“…This paper presents an active islanding detection technique suitable for current controlled inverters. The method is based on reducing the magnitude of the…”
Get full text
Journal Article -
12
An improved algorithm for direct computation of optimal voltage and frequency for induction motors
Published in Engineering science and technology, an international journal (01-10-2017)“…Owing to the constant v/f operation of induction motors which are commonly employed in conveyor belt drives, the core and copper losses are generally high. The…”
Get full text
Journal Article -
13
Power flow management algorithm for photovoltaic systems feeding DC/AC loads
Published in Renewable energy (01-07-2012)“…In this paper, a power flow management algorithm for photovoltaic system feeding DC and AC loads is presented. PV being a major energy source enables the DC…”
Get full text
Journal Article -
14
An improved energy saving v/f control technique for solar powered single-phase induction motor
Published in Energy conversion and management (01-12-2009)“…With the increased energy demand and fast decaying of fossil fuels, renewable energy has remarkably gained importance in recent years. Hence a novel speed…”
Get full text
Journal Article -
15
Enhanced Power Generation From PV Array Under Partial Shading Conditions by Shade Dispersion Using Su Do Ku Configuration
Published in IEEE transactions on sustainable energy (01-07-2013)“…Partial shading of PV arrays reduces the energy yield of PV systems and the arrays exhibit multiple peaks in the P-V characteristics. The losses due to partial…”
Get full text
Journal Article -
16
Identification and Localization of Array Faults With Optimized Placement of Voltage Sensors in a PV System
Published in IEEE transactions on industrial electronics (1982) (01-07-2021)“…The traditional protection devices installed in photovoltaic (PV) arrays generally detect line-line (LL) and line-ground (LG) faults when the fault current…”
Get full text
Journal Article -
17
A smooth co-ordination control for a hybrid autonomous power system (HAPS) with battery energy storage (BES)
Published in Frontiers in Energy (01-03-2015)“…The standalone hybrid power system constitutes a synchronous generator driven by a diesel engine, renewable energy source (wind) apart from a battery energy…”
Get full text
Journal Article -
18
Energy efficient power electronic controller for a capacitor-run single-phase induction motor
Published in Energy conversion and management (01-09-2009)“…At present the speed control of a capacitor-run single-phase induction motor is being achieved by using triac based voltage regulators. This paper proposes a…”
Get full text
Journal Article -
19
An Improved Rotor PLL (R-PLL) for Enhanced Operation of Doubly Fed Induction Machine
Published in IEEE transactions on sustainable energy (01-01-2017)“…A versatile method to compute the rotor position of a three-phase induction machine under balanced or unbalanced grid voltage is proposed in this paper. The…”
Get full text
Journal Article -
20
A versatile method for computation of power pulsations in DFIG under grid imperfections
Published in Renewable energy (01-04-2016)“…In the context of a Doubly Fed Induction Generator (DFIG) connected to the utility grid under unbalanced voltage conditions, the controller design needs to…”
Get full text
Journal Article