Search Results - "INAMI, K"
-
1
MCP-PMT production for Belle II TOP detector and further R&D
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (21-08-2019)“…We have developed 1-inch square-shaped Micro-Channel-Plate PMT (MCP-PMT) for the barrel particle identification detector, named Time-Of-Propagation (TOP)…”
Get full text
Journal Article -
2
Development of a TOP counter for the Super B factory
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (21-09-2008)“…We will in this paper discuss a novel concept for a ring imaging Cherenkov detector. It measures the time of propagation of the Cherenkov photons in a quartz…”
Get full text
Journal Article -
3
TOP counter prototype R&D
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (21-05-2011)“…We have been developing a Cherenkov ring-imaging counter, named TOP counter, as a particle-identification device of the Belle-II detector for the super…”
Get full text
Journal Article -
4
A new approach for measuring the muon anomalous magnetic moment and electric dipole moment
Published in Progress of theoretical and experimental physics (01-05-2019)“…Abstract This paper introduces a new approach to measure the muon magnetic moment anomaly $a_{\mu} = (g-2)/2$ and the muon electric dipole moment (EDM)…”
Get full text
Journal Article -
5
Operational status of the Belle II Time-Of-Propagation counter readout and data acquisition system
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (01-02-2020)“…The front-end electronics system for the Belle II Time-Of-Propagation (TOP) counter was fully installed in May 2016. The detector is a novel particle…”
Get full text
Journal Article -
6
Lifetime-extended MCP-PMT
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (11-02-2011)“…In order to develop a long-lifetime MCP-PMT under high rates of circumstance, we investigated the degradation of the quantum efficiency ( QE) of PMT's with a…”
Get full text
Journal Article -
7
Activation of p38 Mitogen-Activated Protein Kinase by Clotrimazole Induces Multidrug Resistance-Associated Protein 3 Activation through a Novel Transcriptional Element
Published in The Journal of pharmacology and experimental therapeutics (01-10-2016)“…Multidrug resistance-associated protein 3 (MRP3) is a basolaterally localized transporter in the liver and contributes to the transport of various metabolites…”
Get more information
Journal Article -
8
Likelihood analysis of patterns in a time-of-propagation (TOP) counter
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (21-09-2008)“…For the upgrade of the Belle spectrometer, a Time-Of-Propagation (TOP) counter is planned in the barrel region. In this contribution, an analytical likelihood…”
Get full text
Journal Article -
9
MCP-PMT timing property for single photons
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (11-08-2004)“…We have measured the performance, especially the timing properties, of micro-channel plate photo-multiplier tubes (MCP-PMTs) by irradiating with single photons…”
Get full text
Journal Article -
10
Time-of-Propagation Counter for the LEPS
Published in IEEE transactions on nuclear science (01-10-2014)“…We have tested a time-of-propagation (TOP) counter, which is a ring-image Cherenkov counter utilizing the position and propagation time of the Cherenkov light…”
Get full text
Journal Article -
11
Determination of |Vub| from measurements of the inclusive charmless semileptonic partial rates of B mesons using full reconstruction tags
Published in Physical review letters (09-12-2005)Get full text
Journal Article -
12
Time-of-propagation Cherenkov counter for particle identification
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (01-01-2000)“…We describe here a new concept of a Cherenkov detector for particle identification by means of measuring the Time-of-Propagation (TOP) of Cherenkov photons…”
Get full text
Journal Article -
13
Shock-tube and modeling study of methane pyrolysis and oxidation
Published in Combustion and flame (01-08-1999)“…Methane pyrolysis and oxidation were studied behind reflected shock waves in the temperature range 1350–2400 K at pressures of 1.6 to 4.4 atm. Methane decay in…”
Get full text
Journal Article -
14
Progress report on Time-Of-Propagation counter—a new type of ring imaging Cherenkov detector
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (21-11-2002)“…The Time-Of-Propagation (TOP) counter measures both the time and position information of radiated photons with high resolutions to distinguish the Cherenkov…”
Get full text
Journal Article -
15
Evidence for B0 → D+D- and observation of B- → D0D- and B- → D0D- decays
Published in Physical review letters (22-07-2005)Get full text
Journal Article -
16
A high-resolution cylindrical drift chamber for the KEK B-factory
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (01-12-2000)“…The Central Drift Chamber of the BELLE detector at the KEK B-factory is a cylindrical wire chamber device that uses a helium-based gas and aluminum field wires…”
Get full text
Journal Article -
17
Extension of the MCP-PMT lifetime
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (21-12-2017)“…A micro-channel-plate photomultiplier tube (MCP-PMT) is an excellent photon sensor which has a time resolution better than 50ps. However the lifetime of the…”
Get full text
Journal Article -
18
HAPD time-resolution study under single-photon irradiation
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (01-05-2001)“…We have studied the timing property of a Hybrid Avalanche PhotoDiode, Hamamatsu R7110U-07, and attained a time resolution of σ t ∼150 ps for single photons and…”
Get full text
Journal Article -
19
Measurement of e + e − → π + π − ψ ( 2 S ) via initial state radiation at Belle
Published in Physical review. D, Particles, fields, gravitation, and cosmology (12-06-2015)“…We report here measurement of the cross section of e+e- → π+π-ψ ( 2S ) between 4.0 and 5.5 GeV, based on an analysis of initial state radiation events in a…”
Get full text
Journal Article -
20
Search for lepton-flavor-violating τ decays into three leptons with 719 million produced τ+τ− pairs
Published in Physics letters. B (12-04-2010)“…We present a search for lepton-flavor-violating τ decays into three leptons (electrons or muons) using 782 fb−1 of data collected with the Belle detector at…”
Get full text
Journal Article