Search Results - "Hutchison, James M.S."
-
1
Real-time monitoring of drug-induced changes in the stomach acidity of living rats using improved pH-sensitive nitroxides and low-field EPR techniques
Published in Journal of magnetic resonance (1997) (01-09-2006)“…New improved pH-sensitive nitroxides were applied for in vivo studies. An increased stability of the probes towards reduction was achieved by the introduction…”
Get full text
Journal Article -
2
In vivo detection of a pH-sensitive nitroxide in the rat stomach by low-field ESR-based techniques
Published in Magnetic resonance in medicine (01-03-2003)“…A study was made of the in vivo detectability of a pH‐sensitive, imidazolidine spin probe, and the efficacy of low‐frequency electron spin resonance…”
Get full text
Journal Article -
3
Continuous wave MRI of heterogeneous materials
Published in Journal of magnetic resonance (1997) (01-08-2003)“…A prototype continuous wave MRI system operating at 7 T has been used successfully to study a variety of heterogeneous materials exhibiting T 2 relaxation…”
Get full text
Journal Article -
4
Electron Spin Relaxation Time Measurements Using Radiofrequency Longitudinally Detected ESR and Application in Oximetry
Published in Journal of magnetic resonance (1997) (01-03-2001)“…Longitudinally detected ESR (LODESR) involves transverse ESR irradiation with a modulated source and observing oscillations in the spin magnetization parallel…”
Get full text
Journal Article -
5
Cryogenic receive coil and low noise preamplifier for MRI at 0.01 T
Published in Journal of magnetic resonance (1997) (01-03-2010)“…We have investigated the design and construction of liquid nitrogen cooled surface coils made from stranded (litz) copper wire for low field MRI applications…”
Get full text
Journal Article -
6
Design and construction of an actively frequency-switchable RF coil for field-dependent Magnetisation Transfer Contrast MRI with fast field-cycling
Published in Journal of magnetic resonance (1997) (01-11-2010)“…Magnetisation Transfer Contrast (MTC) is an important MR contrast-generating mechanism to characterise the MR-invisible macromolecular protons using an…”
Get full text
Journal Article -
7
Cryogenic receive coil and low noise preamplifier for MRI at 0.01T
Published in Journal of magnetic resonance (1997) (01-03-2010)“…We have investigated the design and construction of liquid nitrogen cooled surface coils made from stranded (litz) copper wire for low field MRI applications…”
Get full text
Journal Article -
8
Field-cycled PEDRI imaging of free radicals with detection at 450 mT
Published in Magnetic resonance imaging (01-02-2005)“…This paper describes the design, construction and use of a field-cycled proton–electron double-resonance imaging (FC-PEDRI) system for the detection and…”
Get full text
Journal Article -
9
Development of a 3-D, multi-nuclear continuous wave NMR imaging system
Published in Journal of magnetic resonance (1997) (01-10-2005)“…The development of a 3-D, multi-nuclear continuous wave NMR imaging (CW-NMRI) system is described and its imaging capability is demonstrated on a range of…”
Get full text
Journal Article -
10
T 1e and T 2e maps derived in vivo from the rat using longitudinally detected electron spin resonance phase imaging: Application to abdominal oxygen mapping
Published in Magnetic resonance in medicine (01-12-2001)“…A novel imaging modality is introduced which uses radiofrequency longitudinally detected electron spin resonance (RF‐LODESR). It is capable of providing…”
Get full text
Journal Article -
11
Design, construction and use of a large-sample field-cycled PEDRI imager
Published in Physics in medicine & biology (01-07-1998)“…The design, construction and use of a large-scale field-cycled proton-electron double-resonance imaging (FC-PEDRI) imager is described. The imager is based on…”
Get more information
Journal Article -
12
T and T maps derived in vivo from the rat using longitudinally detected electron spin resonance phase imaging: Application to abdominal oxygen mapping
Published in Magnetic resonance in medicine (01-12-2001)“…A novel imaging modality is introduced which uses radiofrequency longitudinally detected electron spin resonance (RF‐LODESR). It is capable of providing…”
Get full text
Journal Article -
13
Tuned SQUID-MRI System With Resonant Frequency Adjustment
Published in IEEE transactions on applied superconductivity (01-06-2007)“…We describe a low field, bench-top MRI system for small samples, based on a permanent magnet. Signals are received at 830 kHz using a tuned SQUID magnetometer,…”
Get full text
Journal Article Conference Proceeding -
14
Evaluation of MRI for in vivo monitoring of retinal damage and detachment in experimental ocular inflammation
Published in Magnetic resonance in medicine (01-01-2005)“…Two quantitative methods were developed for investigation of the potential of MRI for in vivo monitoring of retinal damage and detachment in experimental…”
Get full text
Journal Article -
15
T1e and T2e maps derived in vivo from the rat using longitudinally detected electron spin resonance phase imaging: Application to abdominal oxygen mapping
Published in Magnetic resonance in medicine (01-12-2001)“…A novel imaging modality is introduced which uses radiofrequency longitudinally detected electron spin resonance (RF-LODESR). It is capable of providing…”
Get full text
Journal Article -
16
Concomitant magnetic field gradients and their effects on imaging at low magnetic field strengths
Published in Magnetic resonance imaging (1990)“…Low-field NMR imaging systems which use large amplitude field gradient pulses (e.g., in flow velocity encoding) may be subject to the undesirable effects of…”
Get more information
Journal Article -
17
The excretion mechanism of the spin label proxyl carboxylic acid (PCA) from the rat monitored by X-band ESR and PEDRI
Published in Magnetic resonance in medicine (01-04-1997)“…Proton electron double resonance imaging (PEDRI) was used for monitoring in vivo the distribution, metabolism and, in particular, the excretion mechanism of…”
Get more information
Journal Article -
18
Chemically induced analgesic nephropathy in the rat monitored by proton-electron double-resonance imaging (PEDRI)
Published in Magnetic resonance in medicine (01-08-1998)“…Proton-electron double-resonance imaging (PEDRI) was used to assess renal function by monitoring the flow of the exogenous nitroxide free radical proxyl…”
Get more information
Journal Article -
19
An efficient birdcage resonator at 2.5 MHz using a novel multilayer self-capacitance construction technique
Published in Magma (New York, N.Y.) (01-09-1995)“…The birdcage resonator, well appreciated for its high signal-to-noise ratio and its magnetic field uniformity characteristics, operates efficiently in mid- to…”
Get full text
Journal Article -
20
Continuous-wave NMR imaging of solids
Published in Magma (New York, N.Y.) (01-03-1996)“…Current pulsed nuclear magnetic resonance methods of imaging samples such as solids with short spin-spin relaxation times are restricted to use with T2 values…”
Get full text