Search Results - "Hong, Seong Jong"
-
1
SiPM-based gamma detector with a central GRIN lens for a visible/NIRF/gamma multi-modal laparoscope
Published in Optics express (18-01-2021)“…Intraoperative imaging has been studied using conventional devices such as near infrared (NIR) optical probes and gamma probes. However, these devices have…”
Get full text
Journal Article -
2
Proof-of-concept of a multimodal laparoscope for simultaneous NIR/gamma/visible imaging using wavelength division multiplexing
Published in Optics express (02-04-2018)“…An optical/nuclear hybrid surgical technique using ICG- Tc-nanocolloid can improve lesion detectability by detecting both fluorescence and gamma signals…”
Get full text
Journal Article -
3
A Dual-Ended Readout Detector Using a Meantime Method for SiPM TOF-DOI PET
Published in IEEE transactions on nuclear science (01-10-2015)“…We have investigated a dual-ended readout detector based on two silicon photo-multipliers (SiPMs) using a 30 mm long cerium-doped lutetium-yttrium…”
Get full text
Journal Article -
4
An investigation of medical radiation detection using CMOS image sensors in smartphones
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (01-07-2016)“…Medical radiation exposure to patients has increased with the development of diagnostic X-ray devices and multi-channel computed tomography (CT). Despite the…”
Get full text
Journal Article -
5
Development of small-animal PET prototype using silicon photomultiplier (SiPM): initial results of phantom and animal imaging studies
Published in Journal of Nuclear Medicine (01-04-2011)“…Silicon photomultiplier (SiPM; also called a Geiger-mode avalanche photodiode) is a promising semiconductor photosensor in PET and PET/MRI because it is…”
Get full text
Journal Article -
6
A feasibility study of an integrated NIR/gamma/visible imaging system for endoscopic sentinel lymph node mapping
Published in Medical physics (Lancaster) (01-01-2017)“…Purpose The aim of this study is to integrate NIR, gamma, and visible imaging tools into a single endoscopic system to overcome the limitation of NIR using…”
Get full text
Journal Article -
7
A Four-Layer DOI Detector With a Relative Offset for Use in an Animal PET System
Published in IEEE transactions on nuclear science (01-06-2010)“…For animal PET systems to achieve high sensitivity without adversely affecting spatial resolution, they must have the ability to measure depth-of-interaction…”
Get full text
Journal Article -
8
Design and simulation of a novel method for determining depth-of-interaction in a PET scintillation crystal array using a single-ended readout by a multi-anode PMT
Published in Physics in medicine & biology (07-07-2010)“…PET detectors with depth-of-interaction (DOI) encoding capability allow high spatial resolution and high sensitivity to be achieved simultaneously. To obtain…”
Get more information
Journal Article -
9
Development of a front-end analog circuit for multi-channel SiPM readout and performance verification for various PET detector designs
Published in Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment (01-03-2013)“…Silicon photomultipliers (SiPMs) are outstanding photosensors for the development of compact imaging devices and hybrid imaging systems such as positron…”
Get full text
Journal Article -
10
An Investigation Into the Use of Geiger-Mode Solid-State Photomultipliers for Simultaneous PET and MRI Acquisition
Published in IEEE transactions on nuclear science (01-06-2008)“…Photon detecting Geiger-mode solid-state devices are being actively researched and developed because, unlike photo- multiplier tubes (PMT), they can be used in…”
Get full text
Journal Article -
11
Concept Verification of Three-Layer DOI Detectors for Small Animal PET
Published in IEEE transactions on nuclear science (01-06-2008)“…Improved spatial resolution without sacrificing sensitivity is one of the most challenging developmental goals for small animal PET scanners. The 3-layer…”
Get full text
Journal Article -
12
Allocation of flexible and indivisible resources with decision postponement and demand learning
Published in European journal of operational research (01-06-2008)“…We consider a firm that uses two perishable resources to satisfy two demand types. Resources are flexible such that each resource can be used to satisfy either…”
Get full text
Journal Article -
13
A Feasibility Study on the Use of Optical Fibers for the Transfer of Scintillation Light to Silicon Photomultipliers
Published in IEEE transactions on nuclear science (01-06-2011)“…Integrated PET/MRI units with simultaneous acquisition capability are set to play an important role in studies of human breast and prostate imaging and brain…”
Get full text
Journal Article -
14
Initial results of simultaneous PET/MRI experiments with an MRI-compatible silicon photomultiplier PET scanner
Published in Journal of Nuclear Medicine (01-04-2012)“…The most investigated semiconductor photosensor for MRI-compatible PET detectors is the avalanche photodiode (APD). However, the silicon photomultiplier…”
Get full text
Journal Article -
15
Lens implementation on the GATE Monte Carlo toolkit for optical imaging simulation
Published in Journal of biomedical optics (01-02-2018)“…Optical imaging techniques are widely used for in vivo preclinical studies, and it is well known that the Geant4 Application for Emission Tomography (GATE) can…”
Get full text
Journal Article -
16
Development of a multi-modal imaging system for single-gamma and fluorescence fusion images
Published in Nuclear engineering and technology (01-10-2023)“…Although radiation and chemotherapy methods for cancer therapy have advanced significantly, surgical resection is still recommended for most cancers…”
Get full text
Journal Article -
17
Positron emission tomography (PET) detectors with depth-of- interaction (DOI) capability
Published in Biomedical engineering letters (01-05-2011)“…Because positron emission tomography (PET) provides biochemical information in vivo with the sensitivity at the sub-pico-molar level, pre-clinical research…”
Get full text
Journal Article -
18
Comparative evaluation of three microPET series systems using Monte Carlo simulation: sensitivity and scatter fraction
Published in 2007 IEEE Nuclear Science Symposium Conference Record (01-10-2007)“…SIEMENS Inveon is newly released fully multi-modality animal dedicated PET incorporated with SPECT and CT scanner. In this study, Monte Carlo simulation model…”
Get full text
Conference Proceeding -
19
Four-layer DOI detector with a relative offset in animal PET system
Published in 2007 IEEE Nuclear Science Symposium Conference Record (01-10-2007)“…In order to build an animal PET system with high sensitivity and resolution, we propose a four-layer PET system which provides the DOI (depth of interaction)…”
Get full text
Conference Proceeding -
20
Multimodal laparoscopic coincidence gamma imaging system for near-infrared fluorescence guided surgery: a preclinical study
Published in Journal of medical imaging (Bellingham, Wash.) (01-05-2023)“…Minimally invasive surgery has advantages in terms of quality of life and patient outcomes. Recently, near-infrared (NIR) fluorescence guided surgery has…”
Get full text
Journal Article