Search Results - "Holloway, L. C."

Refine Results
  1. 1

    Bit Error Rate Measurements in Reverberation Chambers Using Real-Time Vector Receivers by Floris, S J, Remley, K A, Holloway, C L

    “…We discuss practical measurement implementation methods when using laboratory-grade vector instrumentation to measure bit error rate (BER) in the highly…”
    Get full text
    Journal Article
  2. 2

    Anatomical deformation due to horizontal rotation: towards gantry-free radiation therapy by Buckley, J G, Rai, R, Liney, G P, Dowling, J A, Holloway, L C, Metcalfe, P E, Keall, P J

    Published in Physics in medicine & biology (04-09-2019)
    “…Gantry-free radiation therapy systems may be simpler and more cost effective, particularly for MRI-guided photon or hadron therapy. This study aims to…”
    Get more information
    Journal Article
  3. 3

    Treatment Outcomes of Low-grade Lymphoma of the Orbit by Holloway, C.L., Pickles, T., Croteau, N.S., Wai, E.S.

    “…Radiation therapy can be used with curative intent in patients with low-grade orbital non-Hodgkin's lymphoma (NHL) stages IE and IVE (limited to the bilateral…”
    Get full text
    Journal Article
  4. 4

    Pelvic organ motion and dosimetric implications during horizontal patient rotation for prostate radiation therapy by Buckley, J. G., Dowling, J. A., Sidhom, M., Liney, G. P., Rai, R., Metcalfe, P. E., Holloway, L. C., Keall, P. J.

    Published in Medical physics (Lancaster) (01-01-2021)
    “…Purpose Gantry‐free radiation therapy systems utilizing patient rotation would be simpler and more cost effective than the conventional gantry‐based systems…”
    Get full text
    Journal Article
  5. 5

    A simple model for transit dosimetry based on a water equivalent EPID by Deshpande, S., Blake, S. J., Xing, A., Metcalfe, P. E., Holloway, L. C., Vial, P.

    Published in Medical physics (Lancaster) (01-03-2018)
    “…Purpose The aim of this study was to demonstrate a new model for implementing a transit dosimetry system as a means of in vivo dose verification with a water…”
    Get full text
    Journal Article
  6. 6

    Defining and assessing an anisotropic delineation margin for modern radiotherapy by Bell, L. R., Pogson, E. M., Metcalfe, P. E., Holloway, L. C.

    Published in Medical physics (Lancaster) (01-12-2016)
    “…Purpose: Uncertainty in target volume delineation for modern radiotherapy impacts dosimetry and patient outcomes. Delineation uncertainty is generally…”
    Get full text
    Journal Article
  7. 7

    Dosimetric implications of the addition of 18 fluorodeoxyglucose-positron emission tomography in CT-based radiotherapy planning for non-small-cell lung cancer by Vinod, SK, Kumar, S, Holloway, LC, Shafiq, J

    “…Summary The aim of this study was to assess the impact of F‐18 fluorodeoxyglucose‐positron emission tomography (FDG‐PET) CT on radiotherapy planning parameters…”
    Get full text
    Journal Article
  8. 8

    A model for predicting the power delay profile characteristics inside a room by Holloway, C.L., Cotton, M.G., McKenna, P.

    Published in IEEE transactions on vehicular technology (01-07-1999)
    “…Multipath effects in indoor wireless communication systems exhibit a characteristic power delay profile (PDP) and can be a detriment to the system's…”
    Get full text
    Journal Article
  9. 9

    Averaged transition conditions for electromagnetic fields at a metafilm by Kuester, E.F., Mohamed, M.A., Piket-May, M., Holloway, C.L.

    “…This paper derives generalized sheet transition conditions (GSTCs) for the average electromagnetic fields across a surface distribution of electrically small…”
    Get full text
    Journal Article
  10. 10

    Reflection and transmission properties of a metafilm: with an application to a controllable surface composed of resonant particles by Holloway, C.L., Mohamed, M.A., Kuester, E.F., Dienstfrey, A.

    “…In recent work, we derived generalized sheet transition conditions (GSTCs) for the average (or "macroscopic") electromagnetic fields across a metafilm, which,…”
    Get full text
    Journal Article
  11. 11

    A double negative (DNG) composite medium composed of magnetodielectric spherical particles embedded in a matrix by Holloway, C.L., Kuester, E.F., Baker-Jarvis, J., Kabos, P.

    “…We study a composite medium consisting of insulating magnetodielectric spherical particles embedded in a background matrix. Using results from the literature…”
    Get full text
    Journal Article
  12. 12

    Comparison of electromagnetic absorber used in anechoic and semi-anechoic chambers for emissions and immunity testing of digital devices by Holloway, C.L., DeLyser, R.R., German, R.F., McKenna, P., Kanda, M.

    “…The absorber used in anechoic and semi-anechoic chambers employed for emissions and immunity testing of digital devices is examined. Using reflectivities…”
    Get full text
    Journal Article
  13. 13

    Interobserver Variability in Clinical Target Volume Delineation in Tangential Breast Irradiation: a Comparison between Radiation Oncologists and Radiation Therapists by Batumalai, V, Koh, E.S, Delaney, G.P, Holloway, L.C, Jameson, M.G, Papadatos, G, Lonergan, D.M

    “…Abstract Aims The delineation of target volumes has been radiation oncologist led. If radiation therapists were to undertake this task, work processes may be…”
    Get full text
    Journal Article
  14. 14

    Net and partial inductance of a microstrip ground plane by Holloway, C.L., Kuester, E.F.

    “…A knowledge of the net inductance of the ground plane can aid in the analysis and investigation of printed circuit board emissions. In this paper, we present a…”
    Get full text
    Journal Article
  15. 15

    Analyzing carbon-fiber composite materials with equivalent-Layer models by Holloway, C.L., Sarto, M.S., Johansson, M.

    “…The purpose of this paper is to investigate the use of equivalent-layer models for the analysis of carbon-fiber composite materials. In this paper, we present…”
    Get full text
    Journal Article
  16. 16

    Analysis of composite walls and their effects on short-path propagation modeling by Holloway, C.L., Perini, P.L., DeLyser, R.R., Allen, K.C.

    Published in IEEE transactions on vehicular technology (01-08-1997)
    “…For short-propagation paths, correctly representing reflections of electromagnetic energy from surfaces is critical for accurate signal-level predictions. In…”
    Get full text
    Journal Article
  17. 17

    Use of Reverberation Chambers to Determine the Shielding Effectiveness of Physically Small, Electrically Large Enclosures and Cavities by Holloway, Christopher L., Hill, David A., Sandroni, Marco, Ladbury, John M., Coder, Jason, Koepke, Galen, Marvin, Andrew C., He, Yuhui

    “…With the proliferation of small electric devices in recent years, along with various other applications, there is a growing need to test and determine the…”
    Get full text
    Journal Article
  18. 18
  19. 19

    Effective electromagnetic properties of honeycomb composites, and hollow-pyramidal and alternating-wedge absorbers by Johansson, M., Holloway, C.L., Kuester, E.F.

    “…Closed-form expressions for the effective electromagnetic material properties of honeycomb composites and electromagnetic absorbers constructed in the shapes…”
    Get full text
    Journal Article
  20. 20

    Shielding effectiveness measurements of materials using nested reverberation chambers by Holloway, C.L., Hill, D.A., Ladbury, J., Koepke, G., Garzia, R.

    “…The use of reverberation chambers for determining the shielding effectiveness has the advantage over other techniques in that the reverberation chamber exposes…”
    Get full text
    Journal Article