Search Results - "Hojabri, Mojgan"

  • Showing 1 - 15 results of 15
Refine Results
  1. 1

    IoT-Based PV Array Fault Detection and Classification Using Embedded Supervised Learning Methods by Hojabri, Mojgan, Kellerhals, Samuel, Upadhyay, Govinda, Bowler, Benjamin

    Published in Energies (Basel) (01-03-2022)
    “…Faults on individual modules within a photovoltaic (PV) array can have a significant detrimental effect on the power efficiency and reliability of the entire…”
    Get full text
    Journal Article
  2. 2

    Design and Analysis of a Controllable Reactor Solid-State Circuit Breaker for Enhanced Fault Current Interruption in AC/DC Microgrids by Bakhshi, Ali, Moghim, Ali, Hojabri, Mojgan

    Published in Energies (Basel) (01-05-2024)
    “…The occurrence of short-circuit faults in AC/DC microgrids gives rise to exceptionally high currents with rapid escalation, particularly in DC feeders where…”
    Get full text
    Journal Article
  3. 3

    ML-Based Intermittent Fault Detection, Classification, and Branch Identification in a Distribution Network by Hojabri, Mojgan, Nowak, Severin, Papaemmanouil, Antonios

    Published in Energies (Basel) (01-08-2023)
    “…The accurate detection and identification of intermittent cable faults are helpful in improving the reliability of the distribution system. This paper proposes…”
    Get full text
    Journal Article
  4. 4

    Multifaceted Functionalities of Bridge-Type DC Reactor Fault Current Limiters: An Experimentally Validated Investigation by Behdani, Behzad, Moghim, Ali, Mousavi, Sheyda, Soltanfar, Mostafa, Hojabri, Mojgan

    Published in Energies (Basel) (01-02-2024)
    “…With the ongoing expansion and interconnection of electrical power systems, alongside the rapid proliferation of renewable distributed generations (DGs), the…”
    Get full text
    Journal Article
  5. 5

    Innovative Solid-State Ferroresonance-Suppressing Circuit for Voltage Transformer Protection in Wind Generation Systems by Bakhshi, Ali, Bigdeli, Mehdi, Moradlou, Majid, Behdani, Behzad, Hojabri, Mojgan

    Published in Energies (Basel) (01-12-2023)
    “…Ferroresonance, as an undesirable disturbance, leads to significant overvoltage and distorted waveforms. This phenomenon can be highly damaging to voltage…”
    Get full text
    Journal Article
  6. 6

    Performance evaluation of two PV technologies (c-Si and CIS) for building integrated photovoltaic based on tropical climate condition: A case study in Malaysia by Humada, Ali M., Hojabri, Mojgan, Hamada, Hussein M., Samsuri, Fahmi B., Ahmed, Mushtaq N.

    Published in Energy and buildings (01-05-2016)
    “…•Performance of two important PV plants (c-Si) and (CIS) was evaluated and compared.•Different evaluation criteria are applied and showed superior…”
    Get full text
    Journal Article
  7. 7

    Dual Two-Level Voltage Source Inverter Virtual Inertia Emulation: A Comparative Study by Dashtaki, Mohammad Ali, Nafisi, Hamed, Khorsandi, Amir, Hojabri, Mojgan, Pouresmaeil, Edris

    Published in Energies (Basel) (01-02-2021)
    “…In this paper, the virtual synchronous generator (VSG) concept is utilized in the controller of the grid-connected dual two-level voltage source inverter (DTL…”
    Get full text
    Journal Article
  8. 8

    Photovoltaic Grid-Connected Modeling and Characterization Based on Experimental Results by Humada, Ali M, Hojabri, Mojgan, Sulaiman, Mohd Herwan Bin, Hamada, Hussein M, Ahmed, Mushtaq N

    Published in PloS one (01-04-2016)
    “…A grid-connected photovoltaic (PV) system operates under fluctuated weather condition has been modeled and characterized based on specific test bed. A…”
    Get full text
    Journal Article
  9. 9

    MVDR ALGORITHM BASED LINEAR ANTENNA ARRAY PERFORMANCE ASSESSMENT FOR ADAPTIVE BEAMFORMING APPLICATION by SUHAIL NAJM SHAHAB, AYIB ROSDI ZAINUN, HUSSIEN AHMED ALI, MOJGAN HOJABRI, NURUL HAZLINA NOORDIN

    “…The performance of Minimum Variance Distortionless Response (MVDR) beamformer is sensitive to errors such as the steering vector errors, the finite snapshots,…”
    Get full text
    Journal Article
  10. 10

    Solar cell parameters extraction based on single and double-diode models: A review by Humada, Ali M., Hojabri, Mojgan, Mekhilef, Saad, Hamada, Hussein M.

    Published in Renewable & sustainable energy reviews (01-04-2016)
    “…This paper comprehensively describes and discusses the extraction of the DC parameters of solar cells by mathematical techniques based on single-diode and…”
    Get full text
    Journal Article
  11. 11

    A Comprehensive Survey on Phasor Measurement Unit Applications in Distribution Systems by Hojabri, Mojgan, Dersch, Ulrich, Papaemmanouil, Antonios, Bosshart, Peter

    Published in Energies (Basel) (29-11-2019)
    “…Synchrophasor technology opens a new window for power system observability. Phasor measurement units (PMUs) are able to provide synchronized and accurate data…”
    Get full text
    Journal Article
  12. 12

    Innovating problem solving in power quality devices: A survey based on Dynamic Voltage Restorer case (DVR) by Mansoor, Muhammad, Mariun, Norman, Toudeshki, Arash, Abdul Wahab, Noor Izzri, Mian, Ahmad Umair, Hojabri, Mojgan

    Published in Renewable & sustainable energy reviews (01-04-2017)
    “…The theory of inventive problem solving (TRIZ) is one of emerging creative problem solving methodologies. This paper proposes a way to simplify TRIZ for…”
    Get full text
    Journal Article
  13. 13

    Improving Transient Stability of Power Synchronization Control for Weak Grid Applications by Sepehr, Amir, Pouresmaeil, Mobina, Hojabri, Mojgan, Blaabjerg, Frede, Pouresmaeil, Edris

    “…Power synchronization control (PSC) has a promising potential to be used in interface converters of large- scale renewable generations operating under…”
    Get full text
    Conference Proceeding
  14. 14

    Third-order passive filter improvement for renewable energy systems to meet IEEE 519-1992 standard limits by Hojabri, Mojgan, Hojabri, Mehrdad, Toudeshki, Arash

    “…Second and third-order passive filters (LC and LCL) are interesting filters used for grid-connected inverters. Due to the stability problems of this filter…”
    Get full text
    Conference Proceeding
  15. 15

    Krylov Subspace methods for Available Transfer Capability margins calculations by Hojabri, Mojgan, Hizam, Hashim, Mariun, Norman, Abdullah, Senan Mahmod

    “…Nowadays considering more accuracy and speed to compute Available Transfer Capabilities (ATC) are important for electricity markets. Most studies involved load…”
    Get full text
    Conference Proceeding