Search Results - "Hiroyuki Kudo"
-
1
Nonlocal Total Variation Using the First and Second Order Derivatives and Its Application to CT image Reconstruction
Published in Sensors (Basel, Switzerland) (20-06-2020)“…We propose a new class of nonlocal Total Variation (TV), in which the first derivative and the second derivative are mixed. Since most existing TV considers…”
Get full text
Journal Article -
2
Simple phase unwrapping method with continuous convex minimization
Published in Optics express (29-08-2022)“…Phase unwrapping is a problem to reconstruct true phase values from modulo 2π phase values measured using various phase imaging techniques. This procedure is…”
Get full text
Journal Article -
3
Fundamental Study of a Wristwatch Sweat Lactic Acid Monitor
Published in Biosensors (Basel) (01-04-2024)“…A lactic acid (LA) monitoring system aimed at sweat monitoring was fabricated and tested. The sweat LA monitoring system uses a continuous flow of phosphate…”
Get full text
Journal Article -
4
A fast regularized iterative algorithm for fan-beam CT reconstruction
Published in Physics in medicine & biology (11-07-2019)“…We propose a fast iterative image reconstruction algorithm for normal, short-scan, and super-short-scan fan-beam computed tomography (CT), which aims at…”
Get more information
Journal Article -
5
Development of wrist‐watch type biosensing system for real‐time sweat lactate monitoring
Published in Electronics and communications in Japan (01-09-2023)“…A wrist‐watch type biosensing system for real‐time sweat lactic acid (LA) monitoring was fabricated and tested. The system consists of a microfluidic LA…”
Get full text
Journal Article -
6
Development of a Smartphone-linked Optical Biosensing System for Point-of-care Testing Applications
Published in Sensors and materials (01-01-2024)“…We report a miniaturized batteryless colorimetric biosensing system for measuring saliva components. Our system utilizes a CMOS image sensor and an LED light…”
Get full text
Journal Article -
7
Soft contact lens biosensor for in situ monitoring of tear glucose as non-invasive blood sugar assessment
Published in Talanta (Oxford) (15-01-2011)“…A contact lens (CL) biosensor for in situ monitoring of tear glucose was fabricated and tested. Biocompatible 2-methacryloyloxyethyl phosphorylcholine (MPC)…”
Get full text
Journal Article -
8
Multibeam X-ray tomography optical system for narrow-energy-bandwidth synchrotron radiation
Published in Applied physics express (01-03-2024)“…The design and evaluation experiments of a multibeam X-ray tomography optical system that can be used with synchrotron radiation from sources with a narrow…”
Get full text
Journal Article -
9
Single-shot fringe-pattern analysis algorithm robust against abrupt phase jumps
Published in Optics and lasers in engineering (01-04-2021)“…•Solve phase map using a single fringe pattern.•Recover edge by weighted least-square fitting.•Provide a robust and simple algorithm for phase measurement…”
Get full text
Journal Article -
10
Sparsity-based method for ring artifact elimination in computed tomography
Published in PloS one (28-06-2022)“…Ring artifact elimination is one of the popular problems in computed tomography (CT). It appears in the reconstructed image in the form of bright or dark…”
Get full text
Journal Article -
11
Exploring Frontiers of 4D X-ray Tomography
Published in Applied sciences (01-10-2021)“…In the 4D world of three-dimensional (3D) space plus time that we live in, there is a vast blue ocean in the spatio-temporal domain of micrometers and…”
Get full text
Journal Article -
12
Factors that affect the changes in the satisfaction of Japanese physical therapists with their profession over the years
Published in Journal of Physical Therapy Science (01-01-2021)“…[Purpose] To analyze changes in the level of satisfaction of new physical therapists with their profession over time and in the factors that affect their…”
Get full text
Journal Article -
13
A fiber-optic sorbitol biosensor based on NADH fluorescence detection toward rapid diagnosis of diabetic complications
Published in Analyst (London) (21-09-2015)“…Accumulation of sorbitol in the tissue is known to cause microvascular diabetic complications. In this paper, a fiber-optic biosensor for sorbitol which is…”
Get more information
Journal Article -
14
Salivary uric acid sensor using the fordable “Finger‐Powered” microfluidic device
Published in Electronics and communications in Japan (01-09-2022)“…Here, we report a novel biosensing system using a finger‐powered microfluidic device, which is suitable for daily self‐testing of uric acid in saliva. To…”
Get full text
Journal Article -
15
Multibeam x-ray optical system for high-speed tomography
Published in Optica (20-05-2020)“…X-ray tomography is a powerful method for visualizing the three-dimensional structure of an object with a high spatial resolution. Conventional time-resolved…”
Get full text
Journal Article -
16
Automated Segmentation of Cervical Intervertebral Disks from Videofluorography Using a Convolutional Neural Network and its Performance Evaluation
Published in Journal of signal processing systems (01-03-2020)“…Dysphagia has become an important issue in many countries, and there is a strong need for elucidating the causes of dysphagia. One of the promising ways is to…”
Get full text
Journal Article -
17
Segmentation of cervical intervertebral disks in videofluorography by CNN, multi-channelization and feature selection
Published in International journal for computer assisted radiology and surgery (01-06-2020)“…Purpose Dysphagia has a large impact on the society because it is a risk factor of malnutrition and aspiration pneumonia, and therefore, it is necessary to…”
Get full text
Journal Article -
18
Localization of the Lumbar Plexus in the Psoas Muscle: Considerations for Avoiding Lumbar Plexus Injury during the Transpsoas Approach
Published in Spine Surgery and Related Research (27-03-2021)“…Introduction: Transpsoas lumbar spine surgery is minimally invasive and has very good corrective effects. However, approach-side nerve complications delay…”
Get full text
Journal Article -
19
Relationships between motives to become a physical therapist, delayed graduation, and perceptions of school and internship learning among physical therapy students
Published in Journal of Physical Therapy Science (2018)“…[Purpose] The purpose of this study is to reveal the relationships between physical therapy students’ motives to become physical therapists and their academic…”
Get full text
Journal Article -
20
Evaluation of exercise intensity by real‐time skin lactate monitoring system
Published in Electronics and communications in Japan (01-12-2020)“…A sweat lactic acid (LA) monitoring system embedded on an armband for evaluation of exercise intensity was fabricated and real‐time LA monitoring of a…”
Get full text
Journal Article