Search Results - "Higgins, Steven L"

Refine Results
  1. 1

    Cardiac-Resynchronization Therapy for the Prevention of Heart-Failure Events by Moss, Arthur J, Hall, W. Jackson, Cannom, David S, Klein, Helmut, Brown, Mary W, Daubert, James P, Estes, N.A. Mark, Foster, Elyse, Greenberg, Henry, Higgins, Steven L, Pfeffer, Marc A, Solomon, Scott D, Wilber, David, Zareba, Wojciech

    Published in The New England journal of medicine (01-10-2009)
    “…Cardiac-resynchronization therapy is recommended for patients with advanced, symptomatic heart failure. This clinical trial found benefit in asymptomatic…”
    Get full text
    Journal Article
  2. 2

    Biventricular pacing diminishes the need for implantable cardioverter defibrillator therapy by Higgins, Steven L, Yong, Patrick, Scheck, Donald, McDaniel, Martin, Bollinger, Florence, Vadecha, Mona, Desai, Shoma, Meyer, David B

    “…OBJECTIVES We sought to test the postulate that biventricular pacing diminishes the need for appropriate tachycardia therapy. We reviewed the frequency of…”
    Get full text
    Journal Article
  3. 3
  4. 4
  5. 5
  6. 6
  7. 7

    Prophylactic Implantation of a Defibrillator in Patients with Myocardial Infarction and Reduced Ejection Fraction by Moss, Arthur J, Zareba, Wojciech, Hall, W. Jackson, Klein, Helmut, Wilber, David J, Cannom, David S, Daubert, James P, Higgins, Steven L, Brown, Mary W, Andrews, Mark L

    Published in The New England journal of medicine (21-03-2002)
    “…Patients who have had a myocardial infarction resulting in a reduced left ventricular ejection fraction are at risk for ventricular arrhythmias and sudden…”
    Get full text
    Journal Article
  8. 8

    A novel patch for heart rhythm monitoring: is the Holter monitor obsolete? by Higgins, Steven L

    Published in Future cardiology (01-05-2013)
    “…A number of substantial improvements to the 60-year-old concept of the Holter monitor have recently been developed. One promising advance is the Zio(®) Patch…”
    Get more information
    Journal Article
  9. 9
  10. 10

    Improved Survival with an Implanted Defibrillator in Patients with Coronary Disease at High Risk for Ventricular Arrhythmia by Moss, Arthur J, Hall, W. Jackson, Cannom, David S, Daubert, James P, Higgins, Steven L, Klein, Helmut, Levine, Joseph H, Saksena, Sanjeev, Waldo, Albert L, Wilber, David, Brown, Mary W, Heo, Moonseong

    Published in The New England journal of medicine (26-12-1996)
    “…Unsustained ventricular tachycardia in patients who have had a previous myocardial infarction and have left ventricular dysfunction has been associated with a…”
    Get full text
    Journal Article
  11. 11
  12. 12

    Impact of the multicenter automatic defibrillator implantation trial on implantable cardioverter defibrillator indication trends by Higgins, Steven L

    Published in The American journal of cardiology (11-03-1999)
    “…Since publication of the Multicenter Automatic Defibrillator Implantation Trial (MADIT) in 1996, indications for implantation of implantable cardioverter…”
    Get full text
    Journal Article Conference Proceeding
  13. 13
  14. 14

    Automatic Implantable Cardiac Defibrillators by Higgins, Steven L.

    “…Since its first human application in 1980, the automatic implantable cardioverter defibrillator (ICD) has undergone remarkable advances leading to expanded…”
    Get full text
    Journal Article
  15. 15

    Efficacy of lower-energy biphasic shocks for transthoracic defibrillation:: A follow-up clinical study by Higgins, Steven L, O'Grady, Sharon G, Banville, Isabelle, Chapman, Fred W, Schmitt, Paul W, Lank, Paula, Walker, Robert G, Ilina, Marina

    Published in Prehospital emergency care (01-07-2004)
    “…This clinical study prospectively evaluated the first-shock defibrillation efficacy of 150-joule impedance-compensated, 200-μF biphasic truncated exponential…”
    Get full text
    Journal Article
  16. 16

    The Low Energy Safety Study (LESS): Rationale, design, patient characteristics, and device utilization by Mann, David E., Klein, Richard C., Higgins, Steven L., Freedman, Roger A., Hahn, Stephen J., Huang, Zak Z.

    Published in The American heart journal (01-02-2002)
    “…Background A 10-J energy safety margin has traditionally been used in programing implantable cardioverter defibrillators (ICDs). The Low Energy Safety Study…”
    Get full text
    Journal Article
  17. 17

    Stability: an ICD detection criterion for discriminating atrial fibrillation from ventricular tachycardia by Higgins, S L, Lee, R S, Kramer, R L

    “…The purpose of this study was to review a new implantable cardioverter defibrillator (ICD) detection criterion, stability, to determine if it can effectively…”
    Get more information
    Journal Article
  18. 18

    Biventricular ICD Placement Percutaneously Via the Iliac Vein: Case Reports and a Review by Higgins, Steven

    “…Cardiac resynchronization therapy (CRT) has been demonstrated to improve symptoms of heart failure. As a result, it has become the standard of care in selected…”
    Get full text
    Journal Article
  19. 19
  20. 20

    Which device should “MADIT Protocol” patients receive? by Higgins, Steven L., Klein, Helmut, Nisam, Seah

    Published in The American journal of cardiology (20-03-1997)
    “…An era of prophylactic implantable cardioverter defibrillator (ICD) therapy has been ushered in by the remarkable superiority demonstrated by ICD therapy vs…”
    Get full text
    Journal Article Conference Proceeding