Search Results - "Hepburn, D. M."
-
1
Analysis of HVDC superimposed harmonic voltage effects on partial discharge behavior in solid dielectric media
Published in IEEE transactions on dielectrics and electrical insulation (01-02-2017)“…This paper presents an investigation of effects of high voltage direct current (HVDC) superimposed voltage harmonics on partial discharge (PD) behavior…”
Get full text
Journal Article -
2
Functional disturbance of marrow stromal microenvironment in the myelodysplastic syndromes
Published in Leukemia (01-05-2002)“…The potential contribution of abnormal marrow stromal function to ineffective haemopoiesis in the myelodysplastic syndromes is unclear. We have compared the…”
Get full text
Journal Article -
3
On-line monitoring of relative dielectric losses in cross-bonded cables using sheath currents
Published in IEEE transactions on dielectrics and electrical insulation (01-10-2017)“…Cross-bonded three-phase single-core Cross-linked Polyethylene (XLPE) cables are widely used in power transmission and distribution systems. A great deal has…”
Get full text
Journal Article -
4
Simultaneous measurement of partial discharges using IEC60270 and radio-frequency techniques
Published in IEEE transactions on dielectrics and electrical insulation (01-04-2011)“…Partial discharge (PD) measurement is an established condition monitoring technique used to facilitate the detection of incipient faults in high voltage…”
Get full text
Journal Article -
5
Alpha-particle-induced chromosomal instability in human bone marrow cells
Published in The Lancet (British edition) (08-10-1994)“…alpha-particles, which are ionising radiation of high linear-energy-transfer emitted, for example, from radon or plutonium, pass through tissue as highly…”
Get more information
Journal Article -
6
Application of K-Means method to pattern recognition in on-line cable partial discharge monitoring
Published in IEEE transactions on dielectrics and electrical insulation (01-06-2013)“…On-line Partial Discharge (PD) monitoring is being increasingly adopted in an effort to improve asset management of the vast network of MV and HV power cables…”
Get full text
Journal Article -
7
PD characteristics and degradation in PET insulation with vented and unvented internal voids
Published in Electric power systems research (01-07-2013)“…•PD characteristics and degradation are investigated in vented and unvented voids in PET.•More PD activity is observed in contained unvented voids.•For vented…”
Get full text
Journal Article -
8
Assessment of stromal function, and its potential contribution to deregulation of hematopoiesis in the myelodysplastic syndromes
Published in Haematologica (Roma) (01-10-2001)“…550 John Astor House, 3 Foley Street, University College London Hospitals NHS Trust, London W1 6DN, UK. sudhirtauro@hotmail.com BACKGROUND AND OBJECTIVES: The…”
Get full text
Journal Article -
9
Glutathione S-transferase enzyme expression in hematopoietic cell lines implies a differential protective role for T1 and A1 isoenzymes in erythroid and for M1 in lymphoid lineages
Published in Haematologica (Roma) (01-06-2000)“…Department of Molecular and Cellular Pathology, University of Dundee Medical School, Dundee, UK. BACKGROUND AND OBJECTIVES: Glutathione S-transferases (GSTs)…”
Get full text
Journal Article -
10
Degradation of filled epoxy resin surfaces
Published in Polymer degradation and stability (01-01-2000)“…Many components manufactured from polymeric materials have fillers incorporated into them, to improve the control of the manufacturing process and to assist…”
Get full text
Journal Article -
11
The absorption of mould release agent by epoxy resin
Published in Polymer degradation and stability (01-01-2000)“…A wide range of polymeric materials, including epoxy resins, are moulded to produce components for various uses. Silicon-based release agents are commonly used…”
Get full text
Journal Article -
12
The role of the Sysmex SE9000 immature myeloid index and Sysmex R2000 reticulocyte parameters in optimizing the timing of peripheral blood stem cell harvesting in patients with lymphoma and myeloma
Published in Clinical and laboratory haematology (01-10-1999)“…Peripheral blood CD34/45+ cell (CD34/45) enumeration is an expensive and labour‐intensive investigation but remains the standard assay for optimizing yield and…”
Get full text
Journal Article -
13
Timing of the appearance of multipotential and committed haemopoietic progenitors in peripheral blood after mobilization in patients with lymphoma
Published in Clinical and laboratory haematology (01-04-2001)“…The pattern of emergence of multipotential (CFU‐A) and committed (CFU‐GM and BFU‐E) progenitor cells in peripheral blood has been examined in patients with…”
Get full text
Journal Article -
14
A Methodology for Optimization of Power Systems Demand Due to Electric Vehicle Charging Load
Published in IEEE transactions on power systems (01-08-2012)“…This paper presents a methodology of optimizing power systems demand due to electric vehicle (EV) charging load. Following a brief introduction to the charging…”
Get full text
Journal Article -
15
A NBM based on P-N relationship for DFIG wind turbine fault detection
Published in 2015 International Conference on Smart Grid and Clean Energy Technologies (ICSGCE) (01-10-2015)“…Supervisory control and data acquisition (SCADA) data has been widely applied to identify abnormal conditions in wind turbine generators (WTG). One approach…”
Get full text
Conference Proceeding -
16
Finite element model of HVDC converter harmonic effects on partial discharge
Published in 2016 IEEE International Conference on Dielectrics (ICD) (01-07-2016)“…Partial discharge (PD) measurement as a non-destructive diagnostic tool is a proven technique that has served in both design improvement and condition…”
Get full text
Conference Proceeding -
17
Influence of voltage harmonic phenomena on partial discharge behavior at HVDC
Published in 2016 IEEE International Conference on Dielectrics (ICD) (01-07-2016)“…Insulation is a critical component of any electrical power system, which, when subjected to excessive stress, may lead to premature ageing and eventual…”
Get full text
Conference Proceeding -
18
Fault location and diagnosis in a medium voltage EPR power cable
Published in IEEE transactions on dielectrics and electrical insulation (01-02-2013)“…This paper presents a case study on fault location, characterization and diagnosis in a length of shielded 11 kV medium voltage ethylene-propylene rubber (EPR)…”
Get full text
Journal Article -
19
Second generation wavelet transform for data denoising in PD measurement
Published in IEEE transactions on dielectrics and electrical insulation (01-12-2007)“…Detection and diagnosis of partial discharge (PD) activity has been widely adopted in electrical plant condition monitoring. Analysis and detection of PD in…”
Get full text
Journal Article -
20
Role of thermal effects in discharge degradation of micas used in high power rotating machines
Published in Eighth International Conference on Dielectric Materials, Measurements and Applications (2000)“…The physical and chemical changes to ruby-muscovite and amber-phlogopite mica after localised and bulk thermal stressing are reported herein and compared to…”
Get full text
Conference Proceeding