Search Results - "Henderson, H Thurman"

Refine Results
  1. 1

    An integrated microfluidic biochemical detection system for protein analysis with magnetic bead-based sampling capabilities by Choi, Jin-Woo, Oh, Kwang W, Thomas, Jennifer H, Heineman, William R, Halsall, H Brian, Nevin, Joseph H, Helmicki, Arthur J, Henderson, H Thurman, Ahn, Chong H

    Published in Lab on a chip (01-02-2002)
    “…This paper presents the development and characterization of an integrated microfluidic biochemical detection system for fast and low-volume immunoassays using…”
    Get more information
    Journal Article
  2. 2
  3. 3

    A pulsed mode micromachined flow sensor with temperature drift compensation by Okulan, N., Henderson, H.T., Ahn, C.H.

    Published in IEEE transactions on electron devices (01-02-2000)
    “…A micromachined flow sensor for an integrated microfluidic system, operated in a pulse-modality, has been designed, fabricated and characterized. As a part of…”
    Get full text
    Journal Article
  4. 4

    A new magnetic bead-based, filterless bio-separator with planar electromagnet surfaces for integrated bio-detection systems by Choi, Jin-Woo, Ahn, Chong H, Bhansali, Shekhar, Henderson, H.Thurman

    Published in Sensors and actuators. B, Chemical (25-08-2000)
    “…A new filterless bio-separator separating magnetic microbeads from a carrier fluid has been designed, fabricated, and characterized as a core component of…”
    Get full text
    Journal Article
  5. 5

    Probing human skin as an information-rich smart biological interface using MEMS sensors by Bhansali, Shekhar, Thurman Henderson, H., Hoath, Steven B.

    Published in Microelectronics (02-01-2002)
    “…This paper describes our approach of studying the dynamic, information rich, molecular structure of the ultimate smart interface — human skin — by coupling the…”
    Get full text
    Journal Article
  6. 6
  7. 7

    A silicon thermal astable multivibrator for flow and temperature sensing by Gamage, S.K., Okulan, N., Henderson, H.T.

    Published in IEEE transactions on electron devices (01-12-2002)
    “…Here we report for the first time on a thermal astable multivibrator modality made possible with a silicon bulk micromachined flow sensor. The sensor shows an…”
    Get full text
    Journal Article
  8. 8

    Modeling multilayered MEMS-based micro-fluidic systems by Bhansali, Shekhar, Benjamin, Helen, Upadhyay, Vandana, Okulan, Nihat

    Published in JOM (1989) (01-03-2004)
    “…The first set of simulations was carried out with channels having different inlet and outlet lengths, a constant diameter of 250 µm, and a constant input…”
    Get full text
    Journal Article
  9. 9

    In Vivo Comparison of Two Enteric-Pouch Power Transformers for Circulatory Support by Melvin, David B., Glos, David L., Nebrigic, Dragan, Helmicki, Arthur J., Brown, Rebeccah L., Purcell, Peter N., Henderson, H. Thurman

    Published in Artificial organs (01-08-1997)
    “…: A defunctionalized ileal pouch is thin‐walled (1–2 mm), well perfused (blood flow, 0.3–1.0 ml/g/min), and tactile‐insensitive. If fixed within the abdominal…”
    Get full text
    Journal Article
  10. 10

    Development of a high permeability cored transintegumental power transformer by Helmicki, A J, Melvin, D M, Henderson, H T, Nebrigic, D, Venkat, R, Glos, D L

    Published in ASAIO journal (1992) (01-09-1996)
    “…Circulatory support devices require 10-20 W. Currently, several devices are under development for the transmission of this power via transcutaneous…”
    Get more information
    Journal Article
  11. 11

    Silicon Microsensors for Aerospace Condition Monitoring by Henderson, H. Thurman, Barkhoudarian, Sarkis

    Published in SAE transactions (01-01-1993)
    “…This paper provides several examples of silicon "micromachined" semiconductor sensors with which the authors are involved for aerospace condition monitoring…”
    Get full text
    Journal Article
  12. 12

    A low temperature biochemically compatible bonding technique using fluoropolymers for biochemical microfluidic systems by Han, A., Oh, K.W., Bhansali, S., Thurman Henderson, H., Ahn, C.H.

    “…A new low temperature biochemically compatible bonding technique using fluoropolymers has been developed in this work and characterized in terms of mechanical…”
    Get full text
    Conference Proceeding
  13. 13

    A new planar injection-gated bulk switching device based upon deep impurity trapping by Kapoor, A.K., Henderson, H.T.

    Published in IEEE transactions on electron devices (01-07-1980)
    “…Under the proper conditions, double-injection (DI) diodes with partially compensated deep impurities will exhibit "S"-type switching characteristics similar to…”
    Get full text
    Journal Article
  14. 14

    Injection-gated DI diode with gate-controlled holding voltage by Kapoor, A.K., Henderson, H.T.

    Published in IEEE transactions on electron devices (01-05-1981)
    “…Double-injection (DI) devices consist of an anode (p + ) and a cathode (n + ) in a semi-insulator containing deep traps and exhibit S-type differential…”
    Get full text
    Journal Article
  15. 15

    Double-injection diode as a pulse width modulation element by Kapoor, A.K., Henderson, H.T.

    Published in IEEE electron device letters (01-03-1981)
    “…Double-injection switching devices consist of a p + and an n + junction for injecting holes and electrons into the high resistivity semiconductor substrate…”
    Get full text
    Journal Article
  16. 16

    The use of multiple internal reflection on extrinsic silicon infrared detection by Shang-Bin Ko, Henderson, H.T.

    Published in IEEE transactions on electron devices (01-01-1980)
    “…The sensitivity of a silicon extrinsic infrared detector is enhanced by increasing the absorption path by multiple internal reflection utilizing V-grooves on a…”
    Get full text
    Journal Article
  17. 17

    A negative resistance diode based upon double injection in thallium-doped silicon by Henderson, H.T., Ashley, K.L.

    Published in Proceedings of the IEEE (01-01-1969)
    “…Limited success is reported in growing a thallium-doped silicon crystal, partially compensated with phosphorus. A diode constructed of this material gives a…”
    Get full text
    Journal Article
  18. 18

    A fully-packaged silicon micromachined piezoresistive accelerometer by Walsh, K.M., Henderson, H.T., De Brabander, G.N.

    Published in Proceedings IEEE Southeastcon '92 (1992)
    “…The design and development of a second-generation miniature piezoresistive micromachined accelerometer are presented. Bulk micromachining etching techniques…”
    Get full text
    Conference Proceeding
  19. 19
  20. 20