Search Results - "Hazle, J"
-
1
Nanoshell-Mediated Near-Infrared Thermal Therapy of Tumors under Magnetic Resonance Guidance
Published in Proceedings of the National Academy of Sciences - PNAS (11-11-2003)“…Metal nanoshells are a class of nanoparticles with tunable optical resonances. In this article, an application of this technology to thermal ablative therapy…”
Get full text
Journal Article -
2
Machine learning-based texture analysis for differentiation of large adrenal cortical tumours on CT
Published in Clinical radiology (01-10-2019)“…To compare the efficacy of computed tomography (CT) texture analysis and conventional evaluation by radiologists for differentiation between large adrenal…”
Get full text
Journal Article -
3
Estimating Local Cellular Density in Glioma Using MR Imaging Data
Published in American journal of neuroradiology : AJNR (01-01-2021)“…Increased cellular density is a hallmark of gliomas, both in the bulk of the tumor and in areas of tumor infiltration into surrounding brain. Altered cellular…”
Get full text
Journal Article -
4
Imaging-Based Algorithm for the Local Grading of Glioma
Published in American journal of neuroradiology : AJNR (01-03-2020)“…Gliomas are highly heterogeneous tumors, and optimal treatment depends on identifying and locating the highest grade disease present. Imaging techniques for…”
Get full text
Journal Article -
5
A compressed sensing approach to immobilized nanoparticle localization for superparamagnetic relaxometry
Published in Physics in medicine & biology (23-09-2019)“…Superparamagnetic relaxometry (SPMR) exploits the unique magnetic properties of targeted superparamagnetic iron oxide nanoparticles (SPIOs) to detect small…”
Get more information
Journal Article -
6
Performance Assessment for Brain MR Imaging Registration Methods
Published in American journal of neuroradiology : AJNR (01-05-2017)“…Clinical brain MR imaging registration algorithms are often made available by commercial vendors without figures of merit. The purpose of this study was to…”
Get full text
Journal Article -
7
Hepatocellular carcinoma response to transcatheter arterial chemoembolisation using automatically generated pre-therapeutic tumour volumes by a random forest-based segmentation protocol
Published in Clinical radiology (01-12-2019)“…To demonstrate the feasibility of correlating pre-therapeutic volumes and residual liver volume (RLV) with clinical outcomes: time to progression (TTP) and…”
Get full text
Journal Article -
8
Kalman Filtered MR Temperature Imaging for Laser Induced Thermal Therapies
Published in IEEE transactions on medical imaging (01-04-2012)“…The feasibility of using a stochastic form of Pennes bioheat model within a 3-D finite element based Kalman filter (KF) algorithm is critically evaluated for…”
Get full text
Journal Article -
9
TU‐F‐CAMPUS‐I‐01: Head and Neck Squamous Cell Carcinoma: Short‐Term Repeatability of Apparent Diffusion Coefficient and Intravoxel Incoherent Motion Parameters at 3.0T
Published in Medical physics (Lancaster) (01-06-2015)“…Purpose: Many published studies have recently demonstrated the potential value of intravoxel incoherent motion (IVIM) analysis for disease evaluation. However,…”
Get full text
Journal Article -
10
Accelerated magnetic resonance thermometry in the presence of uncertainties
Published in Physics in medicine & biology (07-01-2017)“…A model-based information theoretic approach is presented to perform the task of magnetic resonance (MR) thermal image reconstruction from a limited number of…”
Get more information
Journal Article -
11
MO‐C‐500‐00: President's Symposium: Introduction S Donaldson, RSNA President
Published in Medical Physics (01-06-2013)“…Unprecedented advances in molecular biology, biomedical imaging and information technology have opened up new avenues towards precision medicine, in which…”
Get full text
Conference Proceeding Journal Article -
12
SU‐A‐WAB‐01: Professional Council Symposium: The Medical Physicist as a Professional Leader ‐ The Importance of Leadership Development
Published in Medical Physics (01-06-2013)“…Medical physicists have a unique combination of education and training in physics principles, radiation physics applications in medicine, human anatomy, as…”
Get full text
Conference Proceeding Journal Article -
13
WE‐C‐116‐03: Spectral Parameter Estimation in the Presence of Macroscopic B0 Variations Using Fast Chemical Shift Imaging
Published in Medical Physics (01-06-2013)“…Purpose: To assess the ability to correct for macroscopic B0 variations to obtain accurate estimates of T2* and amplitude in voxels containing multiple…”
Get full text
Conference Proceeding Journal Article -
14
Computational Modeling and Real-Time Control of Patient-Specific Laser Treatment of Cancer
Published in Annals of biomedical engineering (01-04-2009)“…An adaptive feedback control system is presented which employs a computational model of bioheat transfer in living tissue to guide, in real-time, laser…”
Get full text
Journal Article -
15
SU‐F‐BRCD‐08: Uncertainty Quantification by Generalized Polynomial Chaos for MR‐Guided Laser Induced Thermal Therapy
Published in Medical Physics (01-06-2012)“…Purpose: Magnetic resonance‐guided laser induced thermal therapy (MRgLITT) is a minimally invasive thermal treatment for metastatic brain lesions, offering an…”
Get full text
Conference Proceeding Journal Article -
16
Transurethral ultrasound applicators with directional heating patterns for prostate thermal therapy: In vivo evaluation using magnetic resonance thermometry
Published in Medical physics (Lancaster) (01-02-2004)“…A catheter-based transurethral ultrasound applicator with angularly directional heating patterns has been designed for prostate thermal therapy and evaluated…”
Get full text
Journal Article -
17
WE‐C‐116‐10: Univariate, Multivariate, and Nonlinear Uncertainty Quantification for Magnetic Resonance‐Guided Laser Induced Thermal Therapy
Published in Medical Physics (01-06-2013)“…Purpose: MR‐guided laser‐induced thermal therapy (MRgLITT) is an emerging minimally invasive neurosurgical tool being explored as a treatment alternative for…”
Get full text
Conference Proceeding Journal Article -
18
SU‐E‐J‐53: A Phantom Validation Study of a 3D Background Phase Model for MR Thermometry
Published in Medical Physics (01-06-2012)“…Purpose: The proton resonance frequency (PRF) shift method is the most widely accepted method for magnetic resonance thermal imaging to provide real‐time…”
Get full text
Conference Proceeding Journal Article -
19
Dynamic Contrast-Enhanced MRI Detects Acute Radiation Therapy–Induced Alterations in Mandibular Microvasculature: Prospective Assessment of Imaging Biomarkers of Normal Tissue Injury
Published in International journal of radiation oncology, biology, physics (15-03-2016)Get full text
Journal Article -
20
WE‐E‐500‐01: Physics Pheud
Published in Medical Physics (01-06-2013)“…Come on down! This symposium adopts the format and excitement of a television game show to highlight important and contemporary issues in the science,…”
Get full text
Conference Proceeding Journal Article